46 resultados para perceived exertion

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The aim of this study was to analyze the relationships between the rate of perceived exertion (RPE) of a whole exercise session (RPE-S) and objective measures of exercise intensity during a karate training session.Methods. Eight well-trained karate athletes performed a single training session involving basic karate techniques and sparring. Heart rate (HR) was continuously monitored, while blood lactate ([lac]13) and rating of perceived exertion using the Borg's 6-20 scale were taken each 10-min during exercise. Athletes were also asked to rate their RPE-S using a modified CR-10 scale 30-min after exercise.Results. Significant relationships (P<0.05) were found between RPE-S and mean values of %HRmax (r(p) = 0.91), %HR reserve (r(p) = 0.87), [lac]b(r(p) = 0.96), and RPE (r(p) = 0.78) during the session, but not between RPE-S and the duration of exercise bout (r(s) = 0.28; P > 0.05). RPE-S was also significantly related (P < 0.05) to percentage of time sustained under ventilatory thresold (VT) (r(p) = 0.96), between VT and respiratory compensation point (RCP) (r(p) = 0.93) and above RCP (r(p) = 0.96).Conclusion. These results suggest RPE-S to be a valid tool for assessing interindividual variations in global exercise intensity during karate training. (C) 2010 Elsevier Masson SAS. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of this study were (a) to assess the ability of the rating of perceived exertion (RPE) to predict performance (i.e. number of vertical jumps performed to a fixed jump height) of an intermittent vertical jump exercise, and (b) to determine the ability of RPE to describe the physiological demand of such exercise. Eight healthy men performed intermittent vertical jumps with rest periods of 4, 5, and 6s until fatigue. Heart rate and RPE were recorded every five jumps throughout the sessions. The number of vertical jumps performed was also recorded. Random coefficient growth curve analysis identified relationships between the number of vertical jumps and both RPE and heart rate for which there were similar slopes. In addition, there were no differences between individual slopes and the mean slope for either RPE or heart rate. Moreover, RPE and number of jumps were highly correlated throughout all sessions (r=0.97-0.99; P0.001), as were RPE and heart rate (r=0.93-0.97; P0.001). The findings suggest that RPE can both predict the performance of intermittent vertical jump exercise and describe the physiological demands of such exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Session ratings of perceived exertion (SRPE) have been considered to provide a quantitative evaluation of the entire exercise session in different types of resistance training. In this study we investigated the ability of SRPE to assess exercise strain in a circuit weight training (CWT) workout and the influence of time lag to report SRPE. Ten healthy male volunteers (22.3±2.8 years, 72.5±6.5kg, and 175±5cm) completed a CWT session involving three circuits of five multiple joint exercises with single sets of 20 repetitions at 30% one repetition maximum (1-RM). Heart rate [63.7-75.0% maximum heart rate (%HRmax)], blood lactate (5.6-7.6mM) as well as overall, chest, and active muscle RPE increased significantly (p<0.05) throughout the CWT, but no significant differences were found between ratings of perceived exertion (RPE) types. Overall, chest and active muscle SRPE were accessed 10 minutes, 20 minutes, and 30 minutes after the workout, with no significant main effects or SRPE type×time interaction being found (p>0.05). Finally, no significant differences (p>0.05) were observed between averaged SRPE and RPE responses (overall: 3.7±0.6 vs. 3.5±0.9; chest: 3.8±0.7 vs. 3.6±0.8; active muscle; 3.7±0.7 vs. 3.5±0.7). These results suggest SRPE, irrespective of the moment at which it is taken, to be a useful tool for assessing global exercise strain in a CWT workout, providing coaches, physicians, and exercisers a practical way for monitoring this type of resistance training. © 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To verify the effects of resistance training at the electromyographic fatigue threshold (EMGFT) based on one-repetition maximum strength (1RM), heart rate (HR), rate of perceived exertion (PE) and endurance time (EndT). Methods. Nineteen subjects (training group [TG]: n = 10; control group [CG]: n = 9), performed 1-min bicep curl exercises sets at 25%, 30%, 35% and 40% 1RM. Electromyography (biceps brachii and brachiorradialis), HR and PE were registered. Biceps brachii EMGFT was used to create a load index for an eight-week resistance training programme (three sets until exhaustion/session, two sessions/week) for the TG. The CG only attended one session in the first week and another session in the last week of the eight-week training period for EndT measurement. EndT was determined from the number of repetitions of each of the three sets performed in the first and last training sessions. After training, 1RM, EMGFT, EndT, HR and PE at the different bicep curl load intensities were again measured for both groups. Results. Increases in 1RM (5.9%, p < 0.05) and EndT (> 60%, p < 0.001) after training were found. In addition, PE was reduced at all load intensities (p < 0.05), while no changes were found for HR and EMGFT after training. Conclusions. Strength-endurance training based on the EMGFT improved muscular endurance and also, to a lesser extent, muscular strength. Moreover, the reduced levels of physical exertion after training at the same intensity suggest that endurance training exercises may improve comfort while performing strength exercises.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study developed a Color Scale of Perceived Exertion (RPE-color scale) and assessed its concurrent and construct validity in adult women. One hundred participants (18-77 years), who were habitual exercisers, associated colors with verbal anchors of the Borg RPE scale (RPE-Borg scale) for RPE-color scale development. For RPE-color scale validation, 12 Young (M = 21.7 yr., SD = 1.5) and 10 Older (M = 60.3 yr., SD = 3.5) adult women performed a maximal graded exercise test on a treadmill and reported perceived exertion in both RPE-color and RPE-Borg scales. In the Young group, the RPE-color scale was significantly associated with heart rate and oxygen consumption, having strong correlations with the RPE-Borg scale. In the Older group, the RPE-color scale was significantly associated with heart rate, having moderate to high correlations with the RPE-Borg scale. The RPE-color scale demonstrated concurrent and construct validity in the Young women, as well as construct validity in Older adults.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The present study aimed to examine the reproducibility of heart rate (HR) and rating of perceived exertion (RPE) values obtained during different incremental treadmill tests. Equipment and methods Twenty male, recreational, endurance-trained runners (10-km running pace: 10–15 km·h−1) performed, in a counterbalanced order, three continuous incremental exercise tests with different speed increments (0.5 km·h−1, 1 km·h−1 and 2 km·h−1). Thereafter, each participant performed the three tests again, maintaining the same order as before. The reproducibility of the HR and RPE values were analyzed for all protocols during submaximal intensities (8, 10, 12, and 14 km·h−1). In addition, it was examined the reproducibility of maximal HR (HRmax) and peak RPE (RPEpeak). Results The variability of both the HR and RPE values showed a tendency to decrease over the stages during the incremental test and was not or slightly influenced by the incremental test design. The HR at 14 km·h−1 and HRmax presented the highest reproducibility (CV < 2%). In contrast, the submaximal RPE values showed higher variability indices (i.e., CV > 5.0%). In conclusion, the HR values were highly reproducible during the stages of the incremental test, in contrast to the RPE values that presented limited reproducibility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A percepção subjetiva de esforço (PSE) é determinada de forma não invasiva e utilizada juntamente com a resposta lactacidêmica como indicadores de intensidade durante teste incremental. em campo, especialmente na natação, há dificuldades nas coletas sanguíneas; por isso, utilizam-se protocolos alternativos para estimar o limiar anaeróbio. Assim, os objetivos do estudo foram: prescrever um teste incremental baseado na PSE (Borg 6-20) visando estimar os limiares metabólicos determinados por métodos lactacidêmicos [ajuste bi-segmentado (V LL), concentração fixa-3,5mM (V3,5mM) e distância máxima (V Dmáx)]; relacionar a PSE atribuída em cada estágio com a freqüência cardíaca (FC) e com parâmetros mecânicos de nado [freqüência (FB) e amplitude de braçada (AB)], analisar a utilização da escala 6-20 na regularidade do incremento das velocidades no teste e correlacionar os limiares metabólicos com a velocidade crítica (VC). Para isso, 12 nadadores (16,4 ± 1,3 anos) realizaram dois esforços máximos (200 e 400m); os dados foram utilizados para determinar a VC, velocidade de 400m (V400m) e a freqüência crítica de braçada (FCb); e um teste incremental com intensidade inicial baseada na PSE, respectivamente, 9, 11, 13, 15 e 17; sendo monitorados em todos os estágios a FC, lactacidêmia e os tempos de quatro ciclos de braçadas e das distâncias de 20m (parte central da piscina) e 50m. Posteriormente, foram calculadas as velocidades dos estágios, FB, AB, V LL, V3,5mM e V Dmáx. Utilizaram-se ANOVA e correlação de Pearson para análise dos resultados. Não foram encontradas diferenças entre VC, V Dmáx e V LL, porém a V3,5mM foi inferior às demais velocidades (P < 0,05). Correlações significativas (P < 0,05) foram observadas entre VC versus V400m, V Dmáx e V3,5mM; V400m versus V3,5mM e V Dmáx; V Dmáx versus V LL; e no teste incremental entre PSE versus velocidade, [Lac], FC, FB e AB (P < 0,05). Concluímos que a PSE é uma ferramenta confiável no controle da velocidade dos estágios durante teste incremental na natação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o efeito da técnica de oscilação oral de alta freqüência (com o aparelho Shaker), aplicada em diferentes pressões expiratórias (PE), sobre a função autonômica e parâmetros cardiorrespiratórios. Foram coletados dados de 20 voluntários jovens saudáveis (21,6±1,3 anos), que permaneceram em repouso inicial por 10 minutos e, em seguida, fizeram três séries de dez expirações no aparelho (com intervalo de descanso de 2 minutos entre as séries) em três diferentes PE - pressão livre (PL), de 10 (P10) e de 20 (P20) cmH2O - permanecendo por mais 10 minutos em repouso final. Os dados foram analisados estatisticamente, com nível de significância de 5%. Após a aplicação da técnica, constatou-se diferença significante nos índices de variabilidade da freqüência cardíaca em PL e um aumento significante na pressão arterial sistólica em P20. Na pressão arterial diastólica, freqüência respiratória e saturação periférica de oxigênio não foram encontradas diferenças antes, durante e após a técnica, nas diferentes PE. A percepção do esforço aumentou significantemente ao longo das séries em PL e P20 e entre P10 e P20 em cada série. A freqüência cardíaca (FC) aumentou e diminuiu em sincronia com os movimentos de inspiração e expiração, respectivamente. Foram observadas modificações na modulação autonômica do coração em PL. A aplicação da técnica nessa população, nas diferentes PE analisadas, promoveu modificações no comportamento da FC, no esforço percebido e, em PL, na modulação autonômica do coração.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A relação linear entre intensidade do exercício e taxa de aumento da atividade neuromuscular avaliada pela eletromiografia permite a estimativa do limiar de fadiga, que seria a intensidade que poderia ser mantida indefinidamente sem aumento dos sinais eletromiográficos ao longo do tempo. Levantou-se a hipótese de que a percepção subjetiva de esforço teria comportamento semelhante ao da ativação neuromuscular e que um limiar de esforço percebido (LEP), identificado de forma semelhante ao limiar de fadiga eletromiográfica, poderia coincidir com a velocidade crítica (VCrit). Treze indivíduos de ambos os sexos (23,0 ± 2,5 anos), em uma piscina de 15m de extensão e 2,5m de profundidade, realizaram três testes exaustivos de corrida aquática para determinação dos parâmetros do modelo de velocidade crítica, reportando o esforço percebido (escala de Borg de 6-20 pontos), a cada 15m. Para identificação do LEP, os coeficientes de inclinação das retas do aumento do esforço percebido no tempo (ordenada) e velocidades utilizadas (abscissa) foram ajustados a uma função linear que fornecia um ponto no eixo da velocidade onde, teoricamente, o esforço percebido seria estável indefinidamente. A VCrit foi estimada pelas equações usadas no modelo de velocidade crítica. Para comparação das estimativas de VCrit e do LEP, e de suas associações, foi feita ANOVA para medidas repetidas (p < 0,05) e calculada a correlação de Pearson. Os dados obtidos para a determinação da VCrit atenderam aos critérios adotados para a validade do modelo; a VCrit e o LEP não apresentaram diferença estatística (0,23 ± 0,02m/s x 0,24 ± 0,03m/s) e foram significativamente correlacionados (r = 0,85). Esses resultados sugerem que o LEP parece representar a intensidade máxima de exercício em que variáveis fisiológicas e psicofísicas encontrariam estabilidade, e que esse índice pode ser utilizado na determinação da VCrit.