29 resultados para overdentures

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:It has been stated that mandibular overdentures are more satisfactory than conventional dentures, but problems relating to the use of retrospective ratings, lack of control group and sequential provision of treatment may compromise the findings.Objective:To establish a comparison between treatment with conventional complete dentures and implant-retained overdentures in elderly patients by conducting a literature review.Materials and methods:A search of English language peer-review literature was completed using Medline up to 2008 focusing on evidence-based research. Randomised clinical trials (RCTs) and longitudinal prospective studies were favoured in the review, using a general hierarchical classification. Articles that did not focus exclusively on the comparison of patient satisfaction between complete dentures and overdentures were excluded from further evaluation. The last search was conducted in February 2008. Key terms included quality of life, patient satisfaction, edentulism, complete denture and overdenture.Results:Among the 90 articles found in the initial search, 27 met the inclusion criteria. This included 18 RCTs and eight prospective and one cohort study. Most of the articles stated superiority of the mandibular implant-retained overdenture therapy over the conventional complete denture regarding patient satisfaction and quality of life.Conclusion:Even with implant treatment presenting higher patient satisfaction and improvement of quality of life, it was not possible to establish a direct comparison between the studies due to differences in adopted methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: the aim of this study was to compare the satisfaction and the quality of life in an elderly population using either mandibular conventional dentures or implant-retained overdentures.Materials and methods: A total of 34 patients were divided into two groups: group I-complete dentures users; group II - users of upper complete dentures opposed by implant-retained overdentures. The subjects were submitted to a questionnaire based on Oral Health impact Profile and oral health related quality of life to evaluate their satisfaction levels and quality of life with their prostheses. Data were evaluated using a non-parametric statistical analysis (Fischer test) with significant difference at alpha = 0.05.Results: There were no significant differences between the groups in relation to comfort, aesthetics, chewing ability, overall satisfaction, pain, functional, phonetic, social, and psychological limitations (p > 0.05). Comparing the stability of mandibular dentures, group II presented the better results (p < 0.05).Conclusion: Although the stability of the mandibular implant-retained overdenture was enhanced compared to a conventional denture, the quality of life and satisfaction levels were similar for both the groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The goal of implant treatment is the formation of a direct bone-implant interface contact. Purpose: This study aimed to evaluate the possibilities of immediate loading treatment for edentulous patients rehabilitated with mandibular and maxillary overdentures. Material and methods: A literature review using the PubMed and BIREME databases between the periods of 1977 and 2011 was performed. Results: From an initial yield of 218 titles, 78 articles were selected for text analysis, finally resulting in 23 studies (16 prospective, 6 prospective randomized, and 1 prospective multicenter) that met the inclusion criteria. Conclusion: The immediate loading protocol through which the implants are subjected to occlusal function immediately after their placement was introduced to overcome this limitation. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complete denture fabrication can be a treatment challenge for many dentists, especially when the patient has remaining teeth. So, planning for use of clinical alternatives to improve the treatment prognosis and to enable greater comfort to patient must be considered. This case report describes the use of remaining roots to aid in the stability, support and retention of root-supported overdentures. Thus, immediate prostheses were planned for temporary rehabilitation prior to definitive overdentures. The aim of this study was to demonstrate the planning of root-supported overdentures attached with a ball system for retention associated with immediate dentures between the periods of preparation to fabrication of the definitive overdentures. The proposed treatment met the patient's needs such as being able to carry on normal activities during the sequencing of procedures to be performed over a period of time. The treatment had longevity with patient's knowledge about the necessity of oral hygiene and periodic controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to the purpose of this study was to compare the stress distribution in the peri-implant hard tissue on different attachment systems for mandibular or maxillary implant-retained overdentures. Material and methods: the search for published studies was performed on PubMed/Medline database covering the period of January 2000 to April 2014. The selection of the eligible studies was performed according to including and excluding criteria. Results: a total of 140 studies were screened and according to the search strategy, 21 studies were selected for this review. Eight studies perfomed strain-gauge analysis, 5 evaluated the stress distribution though photoelastic test and 7 performed tridimensional finite element analysis. Only one study in vivo was included. Non-splinted O-rings showed better stress distribution than other bar-clip attachment systems. Conclusions: the present study did not find sufficient evidences regarding the most indicated attachment system for overdentures with better stress distribution for the peri-implant hard tissue. The methodologies analyzed should be complemented with other tests and used as a tool for further clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)