18 resultados para operation mode
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Objective: To assess the influence of air abrasion tips and system operation modes on enamel cutting. Methods: Forty bovine teeth were abraded with the air abrasion system Mach 4.1 for 10 and 15 seconds, employing conventional and sonic tips of 0.45-mm inner diameter and a 90° angle, and 27.5-μm aluminum oxide at 5.51 bar air pressure in continuous and pulsed modes. The width and depth of the resulting cuts were measured in SEM. Results: The multivariate analysis of variances revealed that, compared to the sonic tip, the conventional tip produced shallower cuts independent of the operation mode and the application period. Conclusions: The cutting patterns observed in this study suggest that the pulsed mode produced deeper cuts when both the conventional and sonic tips were used, and that the sonic tip cut more dental tissue than the conventional one.
Resumo:
This work presents a thermoeconomic optimization methodology for the analysis and design of energy systems. This methodology involves economic aspects related to the exergy conception, in order to develop a tool to assist the equipment selection, operation mode choice as well as to optimize the thermal plants design. It also presents the concepts related to exergy in a general scope and in thermoeconomics which combines the thermal sciences principles (thermodynamics, heat transfer, and fluid mechanics) and the economic engineering in order to rationalize energy systems investment decisions, development and operation. Even in this paper, it develops a thermoeconomic methodology through the use of a simple mathematical model, involving thermodynamics parameters and costs evaluation, also defining the objective function as the exergetic production cost. The optimization problem evaluation is developed for two energy systems. First is applied to a steam compression refrigeration system and then to a cogeneration system using backpressure steam turbine. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents a 2kW single-phase high power factor boost rectifier with four cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by Field Programmable Gate Array (FPGA). The soft-switching technique Is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-voltage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related 'to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the Interleaving technique, the rectifer's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) In the input current, in compliance with the TEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for four interleaved cells, and a closed-loop to provide the output voltage regulation, like as a pre-regulator rectifier. Experimental results are presented for a 2kW implemented prototype with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.
Resumo:
This paper presents a multi-cell single-phase high power factor boost rectifier in interleave connection, operating in critical conduction mode, employing a soft-switching technique, and controlled by Field Programmable Gate Array (FPGA). The soft-switching technique is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-vohage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the interleaving technique, the rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for all interleaved cells, and a closed-loop to provide the output voltage regulation, like as a preregulator rectifier. Experimental results are presented for a implemented prototype with two and with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.
Resumo:
In this paper were investigated phase-shift control strategies applied to a four cells interleaved high input-power-factor pre-regulator boost rectifier, operating in critical conduction mode, using a non-dissipative commutation cells and frequency modulation. The digital control has been developed using a hardware description language (VHDL) and implemented using the XC2S200E-SpartanII-E/Xilinx FPGA, performing a true critical conduction operation mode for a generic number of interleaved cells. Experimental results are presented, in order to verify the feasibility and performance of the proposed digital control, through the use of a Xilinx FPGA device.
Resumo:
This paper traces the development of a software tool, based oil a combination of artificial neural networks (ANN) and a few process equations. aiming to serve as a backup operation instrument in the reference generation for real-time controllers of a steel tandem cold mill By emulating the mathematical model responsible for generating presets under normal operational conditions, the system works as ail option to maintain plant operation in the event of a failure in the processing unit that executes the mathematical model. The system, built from the production data collected over six years of plant operation, steered to the replacement of the former backup operation mode (based oil a lookup table). which degraded both product quality and plant productivity. The study showed that ANN are appropriated tools for the intended purpose and that by this instrument it is possible to achieve nearly the totality of the presets needed by this land of process. The text characterizes the problem, relates the investigated options to solve it. justifies the choice of the ANN approach, describes the methodology and system implementation and, finally, shows and discusses the attained results. (C) 2009 Elsevier Ltd. All rights reserved
Resumo:
This work presents the design and procedure of a DC-to-AC converter using a ZVS Commutation Cell developed by Barbi and Martins (1991) and applied to the family of DC-to-DC PWM converters. Firstly, we show the cell applied to buck converter. The stages of operation and the main current and voltage equations of the resonant devices are presented. Next, we adapt the converter to the regenerative operation mode. Hence, the full bridge converter at low frequency operation is conected on the DC-to-DC stage (at high frequency) output ends (Seixas, 1993). Commutation of zero voltage for all switches, PWM at constant frequency and neither overvoltage nor additional current stress are observed by digital simulation. The design example and experimental results obtained by prototype rated at 275 V, 1 kW and 40 kHz are also presented.
Resumo:
This paper presents the analysis of a dc-ac converter using a zero-voltage-switching (ZVS) commutation cell. First, we show the cell applied to the buck converter. The stages of operation are presented along with the main current and voltage equations. Next, we adapt the converter to the regenerative-operation mode. Hence, the full-bridge converter at low-frequency operation is connected in the dc-dc output stage (at high frequency). The main switches commute at zero voltage. The converter operated at constant frequency with pulse-width modulation (PWM), and neither overvoltage nor additional current stress was observed by digital simulation. A design example and experimental results obtained by prototype, rated at 275 V and 1 kW, are also presented. © 1997 IEEE.
Resumo:
Distributed Generators (DG) are generally modeled as PQ or PV buses in power flow studies. But in order to integrate DG units into the distribution systems and control the reactive power injection it is necessary to know the operation mode and the type of connection to the system. This paper presents a single-phase and a three-phase mathematical model to integrate DG in power flow calculations in distribution systems, especially suited for Smart Grid calculations. If the DG is in PV mode, each step of the power flow algorithm calculates the reactive power injection from the DG to the system to keep the voltage in the bus in a predefined level, if the DG is in PQ mode, the power injection is considered as a negative load. The method is tested on two well known test system, presenting single-phase results on 85 bus system, and three-phase results in the IEEE 34 bus test system. © 2011 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
This paper presents a new single-phase interleaved high power factor boost pre-regulator operating in critical conduction mode, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode, when operating in the continuous conduction mode. The interleaving technique is applied in the power cell, providing a significant input current ripple reduction in comparison to discontinuous mode of operation, due to its input current continuous conduction operation. This paper presents a complete modeling for the converter operating in critical conduction mode, resulting in an improved design procedure for interleaved techniques with high input power factor, a complete design procedure, and main simulation results from a design example with two interleaved cells rated at 1kW, 400V output voltage and 220V rms input voltage.
Resumo:
This paper presents a new approach to develop Field Programmable Analog Arrays (FPAAs),(1) which avoids excessive number of programming elements in the signal path, thus enhancing the performance. The paper also introduces a novel FPAA architecture, devoid of the conventional switching and connection modules. The proposed FPAA is based on simple current mode sub-circuits. An uncompounded methodology has been employed for the programming of the Configurable Analog Cell (CAC). Current mode approach has enabled the operation of the FPAA presented here, over almost three decades of frequency range. We have demonstrated the feasibility of the FPAA by implementing some signal processing functions.
Resumo:
This paper is based on the development and experimental analysis of a DCM Boost interleaved converter suitable for application in traction systems of electrical vehicles pulled by electrical motors (Trolleybus), which are powered by urban DC or AC distribution networks. This front-end structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The architecture of proposed converter is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode. Furthermore, the converter can operate as AC-DC converter, or as DC-DC converter providing the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards. The digital controller has been implemented using a low cost FPGA and developed totally using a hardware description language VHDL and fixed point arithmetic. Thus, two control strategies are evaluated considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, the regular PWM modulation and a current correction PWM modulation. In order to verify the feasibility and performance of the proposed system, experimental results from a 15 kW low power scale prototype are presented, operating in DC and AC conditions.
Resumo:
The authors present an offline switching power supply with multiple isolated outputs and unity power factor with the use of only one power processing stage, based on the DC-DC SEPIC (single ended primary inductance converter) modulated by variable hysteresis current control. The principle of operation, the theoretical analysis, the design procedure, an example, and simulation results are presented. A laboratory prototype, rated at 160 W, operating at a maximum switching frequency of 100 kHz, with isolated outputs rated at +5 V/15 A -5 V/1 A, +12 V/6 A and -12 V/1 A, has been built given an input power factor near unity.