32 resultados para operation

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new methodology for the adjustment of the preheating process and steady-state operation of electronic ballasts intended for hot-cathode fluorescent lamps. The classical series-resonant parallel-loaded half-bridge inverter is the power stage analyzed in this paper. In addition, the preheating process is based on the imposition of a constant rms current through the electrodes, in order to provide a proper value of the R-h/R-c ratio before the lamp start. According to the proposed methodology, it is possible to set suitable operating points for, the electronic ballast, considering optimal conditions for the lamps electrodes. Therefore, the proposed methodology for setting the preheating and steady-state operation is a complete platform to the design of electronic ballasts for hot-cathode fluorescent lamps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is based on the development and experimental analysis of a DCM Boost interleaved converter suitable for application in traction systems of electrical vehicles pulled by electrical motors (Trolleybus), which are powered by urban DC or AC distribution networks. This front-end structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The architecture of proposed converter is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode. Furthermore, the converter can operate as AC-DC converter, or as DC-DC converter providing the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards. The digital controller has been implemented using a low cost FPGA and developed totally using a hardware description language VHDL and fixed point arithmetic. Thus, two control strategies are evaluated considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, the regular PWM modulation and a current correction PWM modulation. In order to verify the feasibility and performance of the proposed system, experimental results from a 15 kW low power scale prototype are presented, operating in DC and AC conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the use of differential evolution ( DE), a global search technique inspired by evolutionary theory, to find the parameters that are required to achieve optimum dynamic response of parallel operation of inverters with no interconnection among the controllers is proposed. Basically, in order to reach such a goal, the system is modeled in a certain way that the slopes of P-omega and Q-V curves are the parameters to be tuned. Such parameters, when properly tuned, result in system's eigenvalues located in positions that assure the system's stability and oscillation-free dynamic response with minimum settling time. This paper describes the modeling approach and provides an overview of the motivation for the optimization and a description of the DE technique. Simulation and experimental results are also presented, and they show the viability of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first LHC pp collisions at centre-of-mass energies of 0.9 and 2.36 TeV were recorded by the CMS detector in December 2009. The trajectories of charged particles produced in the collisions were reconstructed using the all-silicon Tracker and their momenta were measured in the 3.8 T axial magnetic field. Results from the Tracker commissioning are presented including studies of timing, efficiency, signal-to-noise, resolution, and ionization energy. Reconstructed tracks are used to benchmark the performance in terms of track and vertex resolutions, reconstruction of decays, estimation of ionization energy loss, as well as identification of photon conversions, nuclear interactions, and heavy-flavour decays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os lagos de pesca recreativa, pesque-pague, surgiram no Brasil em um cenário agrícola denominado como novo rural brasileiro. Este estudo conduzido no noroeste paulista teve como foco o desempenho produtivo dos lagos de pesca recreativa. Foram feitas visitas mensais a nove empreendimentos de pesca recreativa durante seis meses. A cada visita foi aplicado um questionário contendo 13 indicadores de desempenho. Os dados levantados foram submetidos à análise multivariada (MANOVA), análise de componente principal (ACP) e análise de agrupamento. A MANOVA indicou diferenças significativas entre os lagos de pesca recreativa. A ACP revelou, a partir do coeficiente dos autovalores, três atributos: sistema produtivo, gerenciamento pesqueiro e administração operacional. A análise de agrupamento classificou os lagos de pesca recreativa em quatro grupos. Freqüência de pescadores (FP), densidade de estocagem (DE), biomassa de estocagem (BE), captura total (CT) e captura lago dia (CLD), os quais fazem parte do atributo sistema produtivo, mostrando-se os indicadores mais importantes para a avaliação de desempenho dos lagos de pesca recreativa neste estudo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new methodology for the determination of fluorescent lamp models based on equivalent resistances. One important feature of the proposed methodology is concerned with the inclusion of the filaments into the model, considering the effects of dimming operation on the equivalent resistances. The classical Series-Resonant Parallel-Loaded Half-Bridge inverter is used as the power stage of the ballast. Moreover, the variation of the inverter's switching frequency is the dimming technique assumed for the analyses. Results obtained with a F32T8 lamp indicate that the accuracy of the model is very satisfactory. Thus, the lamp models obtained with the proposed methodology have the potential to serve as an important tool for ballast designers, considering the necessity for evaluating the lamp/ballast compatibility, according to issues concerned to the operating conditions of the electrodes' filaments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of the study was to evaluate the influence of an extra corporal perfusion (cardiopulmonary bypass operation - cpb) on activation and biodistribution of Tc-99m labelled granulocytes in pigs with and without inhibition of the granulocytes by a leukocyte inhibition module (LIM). The cpb is often related to an activation of granulocytes resulting in an inflammatory answer. The biological mechanisms are unsolved yet. First trials of our group showed that LIM may inhibit the activation of neutrophils and therefore antagonize a cpb-caused impairment of cardiac function. This study is the continuation of these experiments with a higher number of animals and the focus on scintigraphic imaging. Animals, material, methods: 39 German landrace pigs were subdivided into three groups: group A (control) median sternotomy without cpb, group B with cpb, group C with LIM in addition to cpb. After labelling with Tc-99m-HMPAO autologues granulocytes were reinjected. Subsequently to cpb, the animals underwent scintigraphic imaging. Quantification was performed with ROI evaluation and with tissue samples (section analysis) examined in a well counter. Results:A high uptake of Tc-99m-HMPAO was found in the liver. The count rates in brain, heart, lung, spleen and kidneys were far below. The amount of Tc-99m-activity in the organ related to the half life corrected administered activity [%] was for the tissue samples (group A/B/C): brain 0.01/0.02/0.03; lung 12.1/8.3/11.5; heart 0.35/0.54/0.42; kidney 1.24/0.87/1.02; spleen 4.0/4.0/4.5, liver 16.8/20.9/19.6. The count rates determined by ROI-evaluation of the scintigraphic images related to the total count rate in the image [%] were (group A/B/C): brain 1.1/0.9/1.0; lung 15.6/10.4/12.2; heart 4.0/3.5/3.4; kidney 4.0/2.9/3.2; spleen 7.6/7.7/9.5, liver 23.1/36.7/31.4. A significant difference in the tracer uptake between the groups could neither be detected by scintigraphic imaging nor evaluation of tissue samples. Conclusion: Scintigraphic imaging as well as section analysis showed a comparable biodistribution of the tracer. Therefore, the initial results of our group were not confirmed with a considerably higher number of animals. Neither cpb nor the use of the LIM influenced distribution of Tc-99m-labelled granulocytes in pigs significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an investigation concerning the use of fundamental approximation analysis and a new lamp model for the prediction of the voltage over electrodes' filaments during dimming operation. The lamp model employed in this paper is based on equivalent resistances, which represent the electrodes' filaments and the gas column of a F32T8 lamp. Experimental results are presented in this paper, indicating the validity of the proposed analysis and confirming its potential to serve as an effective tool for the design of dimming electronic ballasts. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, power system operation becomes more complex because of the critical operating conditions resulting from the requirements of a market-driven operation. In this context, efficient methods for optimisation of power system operation and planning become critical to satisfy the operational (technical), financial and economic demands. Therefore, the detailed analysis of modern optimisation techniques as well as their application to the power system problems represent a relevant issue from the scientific and technological points of view. This paper presents a brief overview of the developments on modern mathematical optimisation methods applied to power system operation and planning. Copyright © 2007 Inderscience Enterprises Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work was based on a methodology of development and experimentation, and involved monitoring the dressing operation by processing the acoustic emission and electric power signals to detect the optimal dressing moment. Dressing tests were performed in a surface grinding machine with an aluminium grinding wheel. Dressing analysis software was developed and used to process the signals collected earlier in order to analyse not only the dressing parameters but also the software's ability to indicate the instant when the dressing operation could be concluded. Parameters used in the study of burn in grinding were implemented in order to ascertain if they would also prove efficient in monitoring dressing. A comparative study revealed that some parameters are capable of monitoring the dressing operation. It was possible to verify the parameters effectiveness that today are utilised in burning to monitor dressing as well as to create new parameters for monitoring this operation. Copyright © 2009, Inderscience Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the development and experimental analysis of a special input stage converter for a Trolleybus type vehicle allowing its operation in AC (two wires, single-phase) or DC distribution networks. The architecture of proposed input stage converter is composed by five interleaved boost rectifiers operating in discontinuous conduction mode. Furthermore, due to the power lines characteristics, the proposed input power structure can act as AC to DC or as DC to DC converter providing a proper DC output voltage range required to the DC bus. When operation is AC to DC, the converter is capable to provide high power factor with reduced harmonic distortion for the input current, complying with the restrictions imposed by IEC 61000-3-4 standard. Finally, the main experimental results are presented in order to verify the feasibility of the proposed converter, demonstrating the benefits and the possibility for AC feeding system for trolleybus type vehicle. © 2010 IEEE.