64 resultados para nudging back and forth

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a mathematical model is derived via Lagrange's Equation for a shear building structure that acts as a foundation of a non-ideal direct current electric motor, controlled by a mass loose inside a circular carving. Non-ideal sources of vibrations of structures are those whose characteristics are coupled to the motion of the structure, not being a function of time only as in the ideal case. Thus, in this case, an additional equation of motion is written, related to the motor rotation, coupled to the equation describing the horizontal motion of the shear building. This kind of problem can lead to the so-called Sommerfeld effect: steady state frequencies of the motor will usually increase as more power (voltage) is given to it in a step-by-step fashion. When a resonance condition with the structure is reached, the better part of this energy is consumed to generate large amplitude vibrations of the foundation without sensible change of the motor frequency as before. If additional increase steps in voltage are made, one may reach a situation where the rotor will jump to higher rotation regimes, no steady states being stable in between. As a device of passive control of both large amplitude vibrations and the Sommerfeld effect, a scheme is proposed using a point mass free to bounce back and forth inside a circular carving in the suspended mass of the structure. Numerical simulations of the model are also presented Copyright © 2007 by ASME.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate numerically the dynamical behavior of a non-ideal mechanical system consisting of a vibrating cart containing a particle which can oscillate back and forth colliding with walls carved in the cart. This system represents an impact damper for controlling high-amplitude vibrations and chaotic motion. The motion of the cart is induced by an in-board non-ideal motor driving an unbalanced rotor. We study the phase space of the cart and the bouncing particle, in particular the intertwined smooth and fractal basin boundary structure. The control of the chaotic motion of the cart due to the particle impacts is also investigated. Our numerical results suggests that impact dampers of small masses are effective to suppress chaos, but they also increase the final-state sensitivity of the system in its phase space. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of the influence of motion and initial intra-articular pressure (IAP) on intra-articular pressure profiles in equine cadaver metatarsophalangeal (MTP) joints was undertaken as a prelude to in vivo studies, Eleven equine cadaver MTP joints were submitted to 2 motion frequencies of 5 and 10 cycles/min of flexion and extension, simulating the condition of lower and higher (double) rates of passive motion. These frequencies were applied and pressure profiles generated with initial normal intra-articular pressure (-5 mmHg) and subsequently 30 mmHg intra-articular pressure obtained by injection of previously harvested synovial fluid.The 4 trials performed were 1) normal IAP; 5 cyles/min; 2) normal IAP; 10 cycles/min; 3) IAP at 30 mmHg; 5 cycles/min and 4) IAP at 30 mmHg; 10 cycles/min. The range of joint motion applied (mean +/- s.e.) was 67.6 +/- 1.61 degrees with an excursion from 12.2 +/- 1.2 degrees in extension to 56.2 +/- 2.6 degrees in flexion, Mean pressure recorded in mmHg for the first and last min of each trial, respectively, were 1) -5.7 +/- 0.9 and -6.3 +/- 1.1; 2) -5.3 +/- 1.1 and -6.2 +/- 1.1; 3) 58.8 +/- 8.0 and 42.3 +/- 7.2; 4) 56.6 +/- 3.7 and 40.3 +/- 4.6. Statistical analyses showed a trend for difference between the values for the first and last minute in trial 3 (0.05>P<0.1) with P = 0.1 and significant difference (P = 0.02) between the mean IAP of the first and last min in trial 4. The loss of intra-articular pressure associated with time and motion was 10.5, 16.9, 28.1 and 28.9% for trials 1-4, respectively. As initial intraarticular pressure and motion increased, the percent loss of intra-articular pressure increased.The angle of lowest pressure was 12.2 +/- 1.2 (mean +/- s.e.) in extension in trials 1 and 2, In trials 3 and 4, the lowest pressures were obtained in flexion with the joints at 18.5 +/- 2.0 degrees (mean +/- s.e.). This demonstrated that the joint angle of least pressure changed as the initial intra-articular pressure changed and there would not be a single angle of least pressure for a given joint.The volume of synovial fluid recovered from the MTP joints in trial 3 compared to 4 (trials in which fluid was injected to attain IAP of 30 mmHg) was not significantly different, supporting a soft tissue compliance change as a cause for the significant loss of intra-articular pressure during the 15 min of trial 4.The pressure profiles generated correlate well with in vivo values and demonstrated consistent pressure profiles. Our conclusions are summarised as follows:1. Clinically normal equine MTP joints which were frozen and then later thawed were found to have mostly negative baseline intra-articular pressures, as would be expected in living subjects,2. Alternate pressure profiles of the dorsal and plantar pouch at baseline intra-articular pressure document the presence of pressure forces that would support 'back and forth' fluid movement between joint compartments. This should result in movement of joint fluid during motion, assisting in lubrication and nutrition of articular cartilage,3. If joint pressure was initially greater than normal (30 mmHg), as occurs in diseased equine MTP joints, joint motion further increased joint capsule relaxation (compliance) and, therefore, reduced intra-articular pressure.4. Peak intra-articular pressures reached extremely high values (often >100 mmHg) in flexion when initial pressure was 30 mmHg. Joint effusion pressures recorded for clinical MCP joints are frequently 30 mmHg. These IAP values are expected to produce intermittent synovial ischaemia in clinical cases during joint flexion.5, Additional in vivo studies are necessary to confirm our conclusions from this study and to identify the contributions of fluid absorption and the presence of ischaemia in a vascularised joint.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciências da Motricidade - IBRC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este artigo mostra a importância da utilização de registros de aula para o planejamento de outras aulas/atividades bem como sua utilização como material científico. Faz um levantamento e uma análise das falas de educandos jovens e adultos de uma classe vinculada ao Projeto de Educação de Jovens e Adultos (PEJA) da Universidade Estadual Paulista, Campus de Rio Claro. As falas relacionadas a temas da área de Ciências Biológicas foram extraídas dos registros e analisadas quanto ao seu conteúdo e momento em que apareciam. O texto apresenta também um relato de aula planejada e desenvolvida a partir desses registros e destaca a importância de se considerarem os saberes dos educandos para a realização de uma aula. Reconhece-se a importância do diálogo entre educandos e professores, que a relação de ensino-aprendizagem ocorre do educador para o educando, e vice-versa, e que a análise de registros de aula são uma importante fonte para dados qualitativos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciências Sociais - FFC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refractive and profilometric measurements of lenses were performed through holography with a photorefractive Bi12TiO20 crystal as the recording medium. Two properly aligned diode lasers emitting in the red region were employed as light sources. Both lasers were tuned in order to provide millimetric and sub-millimetric synthetic wavelengths. The surfaces of the test lens were covered by a 25-μm opaque plastic tape in order to allow the lens profilometry upon illuminating them with a collimated beam. The resulting holographic images appear covered by interference fringes corresponding to the wavefront geometry of the wave scattered by the lens. For refractive index measurement a diffusely scattering flat surface was positioned behind the uncovered lens which was also illuminated by a plane wave. The resulting contour interferogram describes the form of the wavefront after the beam traveled back and forth through the lens. The fringe quantitative evaluation was carried out through the four-stepping technique and the resulting phase map and the Branch-cut method was employed for phase unwrapping. The only non-optical procedure for lens characterization was the thickness measurement, made by a dial caliper. Exact ray tracing calculation was performed in order to establish a relation between the output wavefront geometry and the lens parameters like radii of curvature, thickness and refractive index. By quantitatively comparing the theoretical wavefront geometry with the experimental results relative uncertainties bellow 3% for refractive index and 1 % for focal length were obtained. © 2008 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This descriptive study of cross sectional has focused on analyzing the school material weight transported by students associated with children and adolescents overweight in primary and secondary schools. Participants 339 students of both genders, aged 10-19 years. 243 students carrying and average load of 12.65% of his body weight. 53 students were overweight with a BMI of 20,00 to 35,6. 20 overweight students carrying backpacks more than 10% of his body weight. 21% of the students rated complained of back and shoulder pain. This data is very important in the preventive aspects for the individuals studied, as well as others with the same anthropometric characteristics and the same demand.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of different litter materials on litter compaction, broiler feathering and the incidence of carcass lesions. In the experiment, 3240 one-day-old Ross® chicks were selected by sex and distributed according to a completely randomized experimental design in a 2 x 6 factorial arrangement (two sex and six litter materials). The following litter materials were used: wood shavings, rice husks, chopped Napier grass, 50% sugar cane bagasse plus 50% wood shavings, 50% sugar cane bagasse plus 50% rice husks, and pure sugar cane bagasse. Litter compaction was weekly assessed using a penetrometer. on days 21, 35 and 42 of the experimental period, feathering on the back and legs was scored according to a 0 - 10 scale. on day 42, birds were slaughtered and the presence of bruises, scratches and footpad lesions was recorded. Litter material had no effect on bird feathering. Carcass lesions (scratches, bruises and footpad lesions) were influenced by the litter material evaluated. Birds reared on sugarcane bagasse and chopped Napier grass presented more scratches, bruises and footpad lesions than the others. Dermatitis was more evident in birds reared on sugarcane bagasse, chopped Napier grass and the combination of litter materials. It was found that males presented higher incidence of dermatitis and footpad lesions than females. Each litter material presented different compaction degrees, which increased along the experimental period. Sugarcane bagasse, chopped Napier grass and the combination of bedding materials presented the highest degree of compaction, compared with wood shavings and rice husks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Difficulty with literacy acquisition is only one of the symptoms of developmental dyslexia. Dyslexic children also show poor motor coordination and postural control. Those problems could be associated with automaticity, i.e., difficulty in performing a task without dispending a fair amount of conscious efforts. If this is the case, dyslexic children would show difficulties in using "unperceived" sensory cues to control body sway. Therefore, the aim of the study was to examine postural control performance and the coupling between visual information and body sway in dyslexic children. Ten dyslexic children and 10 non-dyslexic children stood upright inside a moving room that remained stationary or oscillated back and forward at frequencies of 0.2 or 0.5 Hz. Body sway magnitude and the relationship between the room's movement and body sway were examined. The results indicated that dyslexic children oscillated more than non-dyslexic children in both stationary and oscillating conditions. Visual manipulation induced body sway in all children but the coupling between visual information and body sway was weaker and more variable in dyslexic children. Based upon these results, we can suggest that dyslexic children use visual information to postural control with the same underlying processes as non-dyslexic children; however, dyslexic children show poorer performance and more variability while relating visual information and motor action even in a task that does not require an active cognitive and conscious motor involvement, which may be a further evidence of automaticity problem. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Hand-held flexible poles which are brought into oscillation to cause alternating forces on trunk, are advocated as training devices that are supposed to solicit increased levels of stabilizing trunk muscle activity. The aim of this study was to verify this claim by comparing electromyographic (EMG) activity of trunk muscles during exercises performed with a flexible pole and a rigid pole.Methods: Twelve healthy females performed three different exercises with flexible and rigid poles. EMG activity of iliocostalis lumborum (IL), multifidus (MU), rectus abdominis (RA), external oblique (EO) and internal oblique (IO), and was continuously measured. The EMG signals were analyzed in time domain by calculation of the Root Mean Square (RMS) amplitudes over 250 ms windows. The mean RMS-values over time were normalized by the maximum RMS obtained for each muscle.Results: The IO showed a 72% greater EMG activity during the exercises performed with the flexible pole than with the rigid pole (p = 0.035). In exercises performed in standing, the IO was significantly more active than when sitting (p = 0.006).Conclusion: As intended, the cyclic forces induced by the oscillating pole did increase trunk muscle activation. However, the effect was limited and significant for the IO muscle only.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to examine if there is any developmental change in the coupling between visual information and trunk sway in infants as they acquire the sitting position. Twenty-four infants distributed in four groups (6-, 7-, 8-, and 9-month-old) were sat inside a moving room that oscillated back and forward at frequencies of 0.2 and 0.5 Hz. The results revealed that trunk sway matched to the moving room at both frequencies but did not differ among the four age groups. Coherence and gain revealed that the coupling was weaker at 0.2 than at 0.5 Hz. Relative phase showed that at 0.2 Hz, infants were swaying with no lag but at 0.5 Hz they were lagging the room. These results showed that the coupling between visual information and trunk sway in infants varies with the visual stimulus but does not change as infants acquire the sitting position. © 2001 Elsevier B.V.