85 resultados para neutron detector

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a methodology for measuring the decay constant of the spontaneous fission of U-238, lambda(f), using nuclear particle track detectors where thermal neutron irradiation is unnecessary. This methodology is based on the fact that the radiation damage caused by spontaneous fission of trans-uranium elements bearing a mass number close to 238 are similar to U-238 spontaneous-fission ones. Loading a thick source of uranium (thickness greater than the fission fragment range) with a small amount of a suitable trans-uranium element (for instance, Pu-242, which presents a spontaneous fission half-life of 6.75(.)10(10) y), it is possible to determine the observation efficiency of a particle-track detector for fission fragments. Procedures concerning our thick source manufacture and uniformity tests of the trans-uranium distribution are also presented. These results make it possible for the exposure of thick uranium sources (without trans-uranium element) to lead to a lambda(f) value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article a new technique for thermal neutron detection using pyroelectric ceramics is described. The detector system is basically constituted of a PZT (lead zirconate titanate) ceramic attached to an uranium disk. The energy released in the uranium fission gives rise to an electrical signal in the detector which is amplified by a lock-in system. The neutron beam impinging on the uranium disk was modulated with a cadmium chopper. Thermal neutron fluxes within the interval of 103 to 106 n/cm2 s have been detected using a U3O8 pellet with 20% enrichment in 235U. © 1992.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two fundamental approaches to fission-track dating involve either an explicit determination of the thermal neutron fluence (φ-method) or a calibration against age standards (ζ-method). The neutron fluence measurements are carried out with metal-activation monitors or with uranium-fission monitors, co-irradiated with the samples. Uranium-fission monitors consist of either a thin mono-atomic) film, or a thick fission source (standard uranium glass) irradiated against a muscovite external track detector. In this work, different techniques for performing neutron-fluence measurements were compared: based on thin-film calibration, based on thick-source calibration, and based on gamma spectrometry of co-irradiated metal monitors (Au, Co). The results suggest that more experiments are needed to make all calibrations consistent, including new measurements of the length of etched induced tracks in mica. Also the standard glass calibration carried out with thin films should be confirmed with a greater number of calibrating irradiations. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detector system that can measure X-ray intensity in the mammographic range of 22 to 36 kVp (equivalent photon energies ofthe beam between 11 and 15 keV) is presented. It consists of a lithium mobate detector and a high-sensitivity current-to-voltage converter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

lsoscalar (T = 0) plus isovector (T = 1) pairing Hamiltonian in LS-coupling. which is important for heavy N = Z nuclei, is solvable in terms of a SO(8) Lie algebra for three special values of the mixing parameter that measures the competition between the T = 0 aid T = 1 pairing. The SO(8) algebra is generated, amongst others, by the S = 1, T = 0 and S = 0, T = 1 pair creation and annihilation operators and corresponding to the three values of the mixing parameter, there are three chains of subalgebras: SO(8) superset of SOST (6) superset of SOS(3) circle times SOT(3), SO(8) superset of [SOS(5) superset of SOS(3)] circle times SOT(3) and SO(8) superset of [SOT(5) superset of SOT(3)] circle times SOS(3). Shell model Lie algebras, with only particle number conserving generators, that are complementary to these three chains of subalgebras are identified and they are used in the classification of states for a given number of nucleons. The classification problem is solved explicitly tor states with SO(8) seniority nu = 0, 1, 2, 3 and 4. Using them, hand structures in isospin space are identified for states with nu = 0, 1, 2 and 3. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the equation of state for neutron matter using the Walecka model including quantum corrections for baryons and sigma mesons through a realignment of the vacuum. We next use this equation of state to calculate the radius, mass and other properties of rotating neutron star.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a search for the flavor-changing neutral current decay B-s(0)->phi mu(+)mu(-) using about 0.45 fb(-1) of data collected in p (p) over bar collisions at root s=1.96 TeV with the D0 detector at the Fermilab Tevatron Collider. We find an upper limit on the branching ratio of this decay normalized to B-s(0)-> J/psi phi of B(B-s(0)->phi mu(+)mu(-))/B(B-s(0)-> J/psi phi)< 4.4x10(-3) at the 95% C.L. Using the central value of the world average branching fraction of B-s(0)-> J/psi phi, the limit corresponds to B(B-s(0)->phi mu(+)mu(-))< 4.1x10(-6) at the 95% C.L., the most stringent upper bound to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have searched for a heavy resonance decaying into a Z+jet final state in p (p) over bar collisions at a center of mass energy of 1.96 TeV at the Fermilab Tevatron collider using the D0 detector. No indication for such a resonance was found in a data sample corresponding to an integrated luminosity of 370 pb(-1). We set upper limits on the cross section times branching fraction for heavy resonance production at the 95% C.L. as a function of the resonance mass and width. The limits are interpreted within the framework of a specific model of excited quark production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

lWe report on a search for second generation leptoquarks (LQ(2)) which decay into a muon plus quark in (p) over barp collisions at a center-of-mass energy of root s = 1.96 TeV in the DO detector using an integrated luminosity of about 300 pb(-1). No evidence for a leptoquark signal is observed and an upper bound on the product of the cross section for single leptoquark production times branching fraction into a quark and a muon was determined for second generation scalar leptoquaiks as a function of the leptoquark mass. This result has been combined with a previously published DO search for leptoquark pair production to obtain leptoquark mass limits as a function of the leptoquark-muon-quark coupling, lambda. Assuming lambda = 1, lower limits on the mass of a second generation scalar leptoquark coupling to a u quark and a muon are m(LQ2) > 274 GeV and m(LQ2) > 226 GeV for beta = 1 and beta = 1/2, respectively. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a search for electroweak production of single top quarks in the s-channel (p (p) over bar -> t (b) over bar +X) and t-channel (p (p) over bar -> tq (b) over bar +X) modes. We have analyzed 230 pb(-1) of data collected with the D0 detector at the Fermilab Tevatron Collider at a center-of-mass energy of root s=1.96 TeV. No evidence for a single top quark signal is found. We set 95% confidence level upper limits on the production cross sections, based on binned likelihoods formed from a neural network output. The observed (expected) limits are 6.4 pb (4.5 pb) in the s-channel and 5.0 pb (5.8 pb) in the t-channel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the accretion-induced magnetic field decay model, in which a frozen field and an incompressible fluid are assumed, we obtain the following results: (1) an analytic relation between the magnetic field and spin period, if the fastness parameter of the accretion disk is neglected (The evolutionary tracks of accreting neutron stars in the P-B diagram in our model are different from the equilibrium period lines when the influence of the fastness parameter is taken into account.); (2) the theoretical minimum spin period of an accreting neutron star is max(1.1ms (DeltaM/M(circle dot))(-1)R(6)(-5/14) I(45)(M/M(circle dot))(-1/2),1.1ms (M/M(circle dot))(-1/2) R(6)(17/14)), independent of the accretion rate (X-ray luminosity) but dependent on the total accretion mass, DeltaM; however, the minimum magnetic field depends on the accretion rate; (3) the magnetic field strength decreases faster with time than does the period.