266 resultados para net buying pressure
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
A theoretical model was developed in order to determine the optimal moment for substituting the sprayer and pressure regulator kit on a center pivot irrigation machine. The model is based on the hypothesis that pressure regulator and sprayer deterioration decrease irrigation uniformity. To compensate the deficit that happens at under irrigated areas, an increase on irrigation depth is required. The model considers: additional water consumption and energy costs, maintenance and labor costs, as well as yield losses associated with under or over irrigated areas. The sum of all these components is compared to buying and installing a new spray kit cost, allowing the farmer to decide the best moment to renovate the sprayer and pressure regulator kits on a center pivot irrigation machine based on economic criteria.
Resumo:
O objetivo deste estudo foi o de avaliar uma associação anestésica com e sem a utilização de relaxante muscular não-despolarizante e seu efeito sobre a pressão intra-ocular de eqüinos. Também objetivou-se uma técnica anestésica sem efeitos adversos que possa ser utilizada em procedimentos e cirurgias oftálmicas nesta espécie animal. Para tanto, dezesseis eqüinos foram divididos aleatoriamente em dois grupos de oito animais cada. Os animais do grupo I foram pré-medicados com romifidina, induzidos com tiletamina/zolazepam e a anestesia foi mantida com halotano e vecurônio. Os animais do grupo II receberam a mesma associação anestésica, com exceção do vecurônio. No decorrer do experimento, a pressão intra-ocular, a pressão arterial e a freqüência cardíaca foram avaliadas em diferentes momentos. A associação anestésica composta pela romifidina, tiletamina/ zolazepam e halotano com e sem vecurônio não promoveu alterações estatisticamente significativas na pressão intra-ocular de eqüinos e o seu uso é exeqüível em procedimentos oftálmicos nesta espécie animal.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The influence of 2 different levels of the inspired oxygen fraction (FiO(2)) on blood gas variables was evaluated in dogs with high intracranial pressure (ICP) during propofol anesthesia (induction followed by a continuous rate infusion [CRI] of 0.6 mg/kg/min) and intermittent positive pressure ventilation (IPPV). Eight adult mongrel dogs were anesthetized on 2 occasions, 21 d apart, and received oxygen at an FiO(2) of 1.0 (G100) or 0.6 (G60) in a randomized crossover fashion. A fiberoptic catheter was implanted on the surface of the right cerebral cortex for assessment of the ICP. An increase in the ICP was induced by temporary ligation of the jugular vein 50 min after induction of anesthesia and immediately after baseline measurement of the ICP. Blood gas measurements were taken 20 min later and then at 15-min intervals for 1 h. Numerical data were submitted to Morrison's multivariate statistical methods. The ICP, the cerebral perfusion pressure and the mean arterial pressure did not differ significantly between FiO(2) levels or measurement times after jugular ligation. The only blood gas values that differed significantly (P < 0.05) were the arterial oxygen partial pressure, which was greater with G100 than with G60 throughout the procedure, and the venous haemoglobin saturation, that was greater with G100 than with G60 at M0. There were no significant differences between FiO(2) levels or measurement times in the following blood gas variables: arterial carbon dioxide partial pressure, arterial hemoglobin saturation, base deficit, bicarbonate concentration, pH, venous oxygen partial pressure, venous carbon dioxide partial pressure and the arterial-to-end-tidal carbon dioxide difference.
Resumo:
Objetivou-se comparar os valores normais de pressão intraocular (PIO) e de produção lacrimal, através de tonometria de aplanação e do teste da lágrima de Schirmer-1 (TLS-1) em cabras da raça Saanen, com diferentes idades e momentos. Trinta e seis cabras da raça Saanen, livres de afecções oculares, foram agrupadas em três categorias etárias (n=12), compreendendo animais com 45, 180 e 549 dias de idade. O TLS-1 e a PIO foram aferidos sempre às 9:00 e às 19:00, durante três dias consecutivos. Os resultados foram avaliados estatisticamente (p<0,05). Relativamente ao horário do dia, a PIO foi significativamente menor às 19:00 (p<0,001) nos animais com 45 dias de idade; os valores do TLS-1 foram significativamente maiores às 19:00 (p=0,004) nas cabras com 549 dias de idade. Considerando-se a somatória dos três dias, ambos os parâmetros foram significativamente menores nos indivíduos com 45 dias de idade (p<0,001). A pressão intraocular e a produção lacrimal em cabras da raça Saanen se elevam de forma significativa até os 180 dias de idade.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Avaliou-se a pressão intra-ocular (PIO) e estimaram-se as correlações entre PIO e pressão de dióxido de carbono (PaCO2) e pH arterial de cinco caracarás (Caracara plancus), anestesiados com isofluorano (ISO) ou sevofluorano (SEV). Valores basais da PIO foram aferidos em ambos os olhos (M0). Cateterizou-se previamente a artéria braquial para obtenção de parâmetros hemogasométricos e cardiorrespiratórios. Anestesia foi induzida com ISO a 5V% e mantida por 40 minutos com 2,5V%. PIO e amostras de sangue foram avaliadas em diferentes momentos até o final do procedimento. Após recuperação, uma segunda anestesia foi realizada com SEV a 6% e mantida com 3,5%. Os parâmetros foram aferidos nos mesmos momentos estabelecidos previamente. A PIO decresceu significativamente (P=0,012) de M0 em todos os momentos e não houve diferença estatística entre ISO e SEV. Correlações significativas entre PIO e PaCO2 e entre PIO e pH sangüíneo foram observadas apenas para a anestesia com SEV. O pH sangüíneo decresceu paralelamente a PIO, enquanto a PaCO2 aumentou, em carcarás anestesiados com isofluorano e sevofluorano.
Resumo:
The effects of adrenergic stimulation on mean circulatory filling pressure (MCFP), central venous pressure (P-CV) and stroke volume (Vs), as well as the effects of altered MCFP through changes of blood volume were investigated in rattlesnakes (Crotalus durissus). MCFP is an estimate of the upstream pressure driving blood towards the heart and is determined by blood volume and the activity of the smooth muscle cells in the veins (venous tone). MCFP can be determined as the plateau in P-CV during a total occlusion of blood flow from the heart.Vs decreased significantly when MCFP was lowered by reducing blood volume in anaesthetised snakes, whereas increased MCFP through infusion of blood (up to 3 ml kg(-1)) only led to a small rise in Vs. Thus, it seems that end-diastolic volume is not affected by an elevated MCFP in rattlesnakes. To investigate adrenergic regulation on venous tone, adrenaline as well as phenylephrine and isoproterenol (alpha- and beta-adrenergic agonists, respectively) were infused as bolus injections (2 and 10 mu g kg(-1)). Adrenaline and phenylephrine caused large increases in MCFP and P-CV, whereas isoproterenol decreased both parameters. This was also the case in fully recovered snakes. Therefore, adrenaline affects venous tone through both alpha- and beta-adrenergic receptors, but the alpha-adrenergic receptor dominates at the dosages used in the present study. Injection of the nitric oxide donor SNP caused a significant decrease in P-CV and MCFP. Thus, nitric oxide seems to affect venous tone.
Resumo:
The study was conducted at the Research Laboratory of Hydraulic and Irrigation Group in the Rural Engineering Department, Technical University of Madrid (Universidad Politecnica de Madrid), Madrid, Spain. Water temperatures of 20, 30, 40 degrees C and system pressures often encountered in irrigation practices of 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190 and 200 k Pa were applied to determine the effects of different water temperatures and pressures on emitter discharge. Non-pressure compensating in-line emitter which has turbulent flow regime with a long-path (labyrinth), emitter discharge was 4 L h(-1) at system pressure of 100 kPa according to the manufacturer recommended, was used. Emitters were spaced 20 cm along the drip laterals with 16 mm diameter. Discharge equations and coefficients of variation related to temperatures of 20, 30 and 40 degrees C were obtained as q = 0.375H(0.51), q = 0.358H(0.52), q = 0.346H(0.53) and 2.68, 2.09, 3.65, respectively. Discharge of the emitter was affected by different system pressures and increased as potentially (R = 0993-0996). In general. the emitter discharge increased with increasing temperature. However, especially in the common system pressures of 90-120 k Pa, differences of obtained emitter discharges between the different water temperatures were not significant (1%).
Resumo:
This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.
Resumo:
Objectives To analyze the association between resting heart rate and blood pressure in male children and adolescents and to identify if this association is mediated by important confounders.Study design Cross-sectional study carried out with 356 male children and adolescents from 8 to 18 years old. Resting heart rate was measured by a portable heart rate monitor according to recommendations and stratified into quartiles. Blood pressure was measured with an electronic device previously validated for pediatric populations. Body fatness was estimated by a dual-energy x-ray absorptiometry.Results Obese subjects had values of resting heart rate 7.8% higher than nonobese (P = .001). Hypertensive children and adolescents also had elevated values of resting heart rate (P = .001). When the sample was stratified in nonobese and obese, the higher quartile of resting heart rate was associated with hypertension in both groups of children and adolescents.Conclusions This study confirms the existence of a relationship between elevated resting heart rate and increased blood pressure in a pediatric population, independent of adiposity, ethnicity and age. (J Pediatr 2011; 158:634-7).
Resumo:
Objective: To assess viability of the development of percentage body fat cutoffs based on blood pressure values in Brazilian adolescents.Methods: A cross-sectional study was conducted with a sample of 358 male subjects from 8 to 18 years old. Blood pressure was measured by the oscilometric method, and body composition was measured by dual-energy X-ray absorptiometry (DXA).Results: For the identification of elevated blood pressure, these nationally developed body fat cutoffs presented relative accuracy. The cutoffs were significantly associated with elevated blood pressure [odds ratio = 5.91 (95% confidence interval: 3.54-9.86)].Conclusions: Development of national body fat cutoffs is viable, because presence of high accuracy is an indication of elevated blood pressure.