12 resultados para movie camera
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
OBJETIVO: Avaliar quantitativamente as mudanças da posição palpebral e as medidas da fenda palpebral de indivíduos acima dos 50 anos. MÉTODOS: Estudo observacional, tendo sido avaliados 325 indivíduos, com idade acima de 50 anos, segundo distância intercantal, largura e altura da fenda palpebral, ângulo palpebral externo e interno, distância entre o reflexo pupilar e a margem da pálpebra superior (distância reflexo-margem) e a área total da fenda palpebral. Utilizou-se filmadora Sony Lithium para obtenção das imagens digitais, com o indivíduo fixando um objeto a 1 metro de distância, sendo as imagens transferidas posteriormente para computador McIntosh G4 e processadas pelo programa NIH 1.58. Os dados foram submetidos à análise estatística. RESULTADOS: Os participantes apresentavam dermatocálase (96,5%), ptose do supercílio (60,8%), prolapso de gordura orbital (50,0%) ou ptose palpebral (39,1%). As alterações foram bilaterais em 68,8% dos indivíduos. A distância intercantal aumentou com a idade; a largura da fenda palpebral, a distância reflexo-margem e a medida do ângulo externo diminuíram nos mais idosos. As diferenças foram mais significativas quando os olhos foram estudados separadamente. CONCLUSÃO: A distância intercantal aumenta, ao passo que a largura da fenda palpebral, a distância reflexo-margem e a área total da fenda palpebral diminuem com o aumento da idade.
Resumo:
Purpose: To determine palpebral dimensions and development in Brazilian children using digital images. Methods: An observational study was performed measuring eyelid angles, palpebral fissure area and interpupillary distance in 220 children aged from 4 to 72 months. Digital images were obtained with a Sony Lithium movie camera (Sony DCR-TRV110, Brazil) in frontal view from awake children in primary ocular position; the object of observation was located at pupil height. The images were saved to tape, transferred to a Macintosh G4 (Apple Computer Inc., USA) computer and processed using NIH 1.58 software (NTIS, 5285 Port Royal Rd., Springfield, VA 22161, USA). Data were submitted to statistical analysis. Results: All parameters studied increased with age. The outer palpebral angle was greater than the inner, and palpebral fissure and angles showed greater changes between 4 and 5 months old and at around 24 to 36 months. Conclusion: There are significant variations in palpebral dimensions in children under 72 months old, especially around 24 to 36 months. Copyright © 2006 Informa Healthcare.
Resumo:
Pós-graduação em Ciências Cartográficas - FCT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Comunicação - FAAC
Resumo:
Pós-graduação em Engenharia Civil e Ambiental - FEB
Resumo:
O texto analisa o filme Santo Antonio e a vaca, realizado no ano de 1958, na cidade de Araraquara. Nesse filme pioneiro, procura-se criar um cinema com narrativa e estética caipiras, mas para subverter a moderna e tecnológica linguagem cinematográfica. Santo Antônio e a Vaca resgata um tema típico das comunidades rurais, a chamadan narrativa moral na forma do “causo”, e o apresenta com acanhadas tomadas de câmera, sem a exploração dos recursos especialmente cinematográficos. O tema e a forma do filme foram adotados por seu idealizador e diretor, Wallace Leal, como uma forma de reação à demolição do teatro da cidade para ceder lugar à construção que abrigaria a prefeitura de Araraquara. À época em que o teatro foi demolido, Wallace Leal dirigia uma trupe teatral, que apresentava com certo sucesso o espetáculo que inspiraria e daria nome à fita.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Few quantitative data exist on pupil diameter, particularly in children. In this article we describe an analysis of pupil diameter and pupil area in normal preschool children during attentive gaze (AG) and spontaneous gaze (SG) using digital imaging. The pupil diameter and pupil area of 200 preschool children aged 4 to 6 years were evaluated. The images were recorded with a digital camera, transferred to a computer, processed by movie software and submitted to the Invert filter of Adobe Photoshop (R) software. Three consecutive measures of pupil diameter and pupil area were taken for both eyes during AG and SG. Arithmetic means of each parameter were calculated and data were expressed in millimeters. Mean pupil diameter was similar for both eyes, presenting values of 4.9 mm during AG and 4.1 mm during SG. Mean pupil area was also similar for both eyes, presenting values of 15.6 mm(2) and 9.1 mm(2) during AG and SG, respectively. There were no differences between boys and girls. However, 6-year-old children showed lower pupil diameter and area under both evaluation conditions.
Resumo:
The problem of dynamic camera calibration considering moving objects in close range environments using straight lines as references is addressed. A mathematical model for the correspondence of a straight line in the object and image spaces is discussed. This model is based on the equivalence between the vector normal to the interpretation plane in the image space and the vector normal to the rotated interpretation plane in the object space. In order to solve the dynamic camera calibration, Kalman Filtering is applied; an iterative process based on the recursive property of the Kalman Filter is defined, using the sequentially estimated camera orientation parameters to feedback the feature extraction process in the image. For the dynamic case, e.g. an image sequence of a moving object, a state prediction and a covariance matrix for the next instant is obtained using the available estimates and the system model. Filtered state estimates can be computed from these predicted estimates using the Kalman Filtering approach and based on the system model parameters with good quality, for each instant of an image sequence. The proposed approach was tested with simulated and real data. Experiments with real data were carried out in a controlled environment, considering a sequence of images of a moving cube in a linear trajectory over a flat surface.
Resumo:
The aim of this work is to evaluate the influence of point measurements in images, with subpixel accuracy, and its contribution in the calibration of digital cameras. Also, the effect of subpixel measurements in 3D coordinates of check points in the object space will be evaluated. With this purpose, an algorithm that allows subpixel accuracy was implemented for semi-automatic determination of points of interest, based on Fõrstner operator. Experiments were accomplished with a block of images acquired with the multispectral camera DuncanTech MS3100-CIR. The influence of subpixel measurements in the adjustment by Least Square Method (LSM) was evaluated by the comparison of estimated standard deviation of parameters in both situations, with manual measurement (pixel accuracy) and with subpixel estimation. Additionally, the influence of subpixel measurements in the 3D reconstruction was also analyzed. Based on the obtained results, i.e., on the quantification of the standard deviation reduction in the Inner Orientation Parameters (IOP) and also in the relative error of the 3D reconstruction, it was shown that measurements with subpixel accuracy are relevant for some tasks in Photogrammetry, mainly for those in which the metric quality is of great relevance, as Camera Calibration.
Resumo:
The article discusses a proposal of displacement measurement using a unique digital camera aiming at to exploit its feasibility for Modal Analysis applications. The proposal discusses a non-contact measuring approach able to measure multiple points simultaneously by using a unique digital camera. A modal analysis of a reduced scale lab building structure based only at the responses of the structure measured with the camera is presented. It focuses at the feasibility of using a simple ordinary camera for performing the output only modal analysis of structures and its advantage. The modal parameters of the structure are estimated from the camera data and also by using ordinary experimental modal analysis based on the Frequency Response Function (FRF) obtained by using the usual sensors like accelerometer and force cell. The comparison of the both analysis showed that the technique is promising noncontact measuring tool relatively simple and effective to be used in structural modal analysis