38 resultados para moment closure

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we describe an experimental setup in which an electric current is used to determine the angular velocity attained by a plate rotating around a shaft in response to a torque applied for a given period. Based on this information, we show how the moment of inertia of a plate can be determined using a procedure that differs considerably from the ones most commonly used, which generally involve time measurements. Some experimental results are also presented which allow one to determine parameters such as the exponents and constant of the conventional equation of a plate's moment of inertia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an experimental set-up which differs from the traditional ones is established in order to determine the moment of inertia of a right circular cone. Its angular variation and inertia ellipsoid are determined by means of an experimental study. In addition, a system that allows for the evaluation of the angular acceleration and torque through electric current or frequency measurement is utilized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o objetivo de estudar os efeitos do diclofenaco sódico sobre a cicatrização da parede abdominal de ratos, foram utilizados 80 animais da linhagem Wistar divididos em dois grupos: Grupo 1: formado por 40 animais submetidos à laparotomia mediana e à injeção intramuscular de soro fisiológico durante quatro dias. Grupo 2: formado por 40 animais submetidos à laparotomia mediana e à injeção intramuscular de diclofenaco sódico durante quatro dias. Animais de ambos os grupos foram analisados no 5°, 7°, 14° e 21° dias de pós-operatório, correspondendo, respectivamente à M1, M2, M3 e M4. em cada momento foram estudados 10 animais e os parâmetros analisados foram a evolução clínica, a força de ruptura, estudo histológico e o conteúdo de colágeno tecidual da parede abdominal. Os animais do grupo tratado apresentaram como complicações, deiscência e/ou hérnia incisional, perda ponderal e taxa de mortalidade, complicações estas não evidenciadas no grupo controle. Observamos também neste grupo, diminuição da força de ruptura no 7° e 14° dia de pós-operatório e diminuição da concentração de colágeno tecidual no 5°, 7° e 14° dia de pós-operatório. Ambos os parâmetros retornaram a valores normais no 21° dia de pós-operatório. Quanto ao estudo histológico, concluímos que a cicatriz da parede abdominal dos animais tratados com D.S. apresentam retardo do processo cicatricial em relação aos seus controles, caracterizado por uma menor fibrogênese, menor densidade de fibras colágenas, além de um número maior de complicações, como microabscessos, em torno dos fios de sutura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em 12 fêmeas e 12 machos da raça Puro Sangue Inglês com idade média de 12 meses, avaliou-se os valores normais da densidade mineral óssea do carpo acessório em milímetros de alumínio (mmAl) até o momento do fechamento completo da epífise distal do rádio, por meio do método de densitometria óptica em imagens radiográficas. A avaliação foi realizada por meio de um programa computacional (software) especialmente desenvolvido para medida de densidade óptica em filmes de raios-X, o qual contém a imagem radiográfica do osso carpo acessório, região de partes moles adjacente ao carpo acessório e os degraus de uma escala de alumínio (phatom), que permitiu a medida de densidade mineral óssea, sendo esta a média aritmética da região de interesse determinada no osso carpo acessório correspondente ao valor em milímetros da escala. Os valores da densidade mineral óssea em mmAl do acessório do carpo em função da idade não apresentaram diferenças entre os sexos (p=0,86) permitindo que uma equação de reta fosse ajustada para ambos os sexos (densidade mineral óssea (DMO) mmAl = 3.109 + 0,056 x idade em meses), na faixa etária estudada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mineralization of the articular cartilage is a pathological condition associated with age and certain joint diseases in humans and other mammals. In this work, we describe a physiological process of articular cartilage mineralization in bullfrogs. Articular cartilage of the proximal and distal ends of the femur and of the proximal end of the tibia-fibula was studied in animals of different ages. Mineralization of the articular cartilage was detected in animals at 1 month post-transformation. This mineralization, which appeared before the hypertrophic cartilage showed any calcium deposition, began at a restricted site in the lateral expansion of the cartilage and then progressed to other areas of the epiphyseal cartilage. Mineralized structures were identified by von Kossa's staining and by in vivo incorporation of calcein green. Element analysis showed that calcium crystals consisted of poorly crystalline hydroxyapatite. Mineralized matrix was initially spherical structures that generally coalesced after a certain size to occupy larger areas of the cartilage. Alkaline phosphatase activity was detected at the plasma membrane of nearby chondrocytes and in extracellular matrix. Apoptosis was detected by the TUNEL (TDT-mediated dUTP-biotin nick end-labeling) reaction in some articular chondrocytes from mineralized areas. The area occupied by calcium crystals increased significantly in older animals, especially in areas under compression. Ultrastructural analyses showed clusters of needle-like crystals in the extracellular matrix around the chondrocytes and large blocks of mineralized matrix. In 4-year-old animals, some lamellar bone (containing bone marrow) occurred in the same area as articular cartilage mineralization. These results show that the articular cartilage of R. catesbeiana undergoes precocious and progressive mineralization that is apparently stimulated by compressive forces. We suggest that this mineralization is involved in the closure of bone extremities, since mineralization appears to precede the formation of a rudimentary secondary center of ossification in older animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the q-state Potts models for q less than or equal to 4, in the scaling regimes close to their critical or tricritical points. Starting from the kink S-matrix elements proposed by Chim and Zamolodchikov, the bootstrap is closed for the scaling regions of all critical points, and for the tricritical points when 4 > q greater than or equal to 2. We also note a curious appearance of the extended last line of Freudenthal's magic square in connection with the Potts models. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate some proposals to solve the electric charge quantization puzzle that simultaneously explain the recent measured deviation on the muon anomalous magnetic moment. For this we assess extensions of the electro-weak standard model spanning modifications on the scalar sector only. It is interesting to verify that one can have modest extensions which easily account for the solution for both problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: O objetivo desde artigo foi relatar um caso clínico de fechamento de fístula buco-sinusal tardia utilizando rotação de enxerto de tecido adiposo pediculado do corpo adiposo da bochecha. DESCRIÇÃO do CASO: Paciente do sexo masculino, 66 anos, leucoderma, em boas condições de saúde geral, foi encaminhado para fechamento de extensa comunicação buco-sinusal. Ao exame clínico, observou-se uma fístula de aproximadamente 10 mm de diâmetro comunicando a cavidade oral com o seio maxilar. A cirurgia foi realizada em nível ambulatorial, sob anestesia local, para fechar a fístula buco-sinusal com um enxerto de tecido adiposo pediculado do corpo adiposo da bochecha. A reparação da ferida e o fechamento do defeito foram observados no pós-operatório de 30 dias, com completa epitelização. CONCLUSÃO: O enxerto pediculado de tecido do corpo adiposo da bochecha mostrou-se uma alternativa simples, eficaz e segura no fechamento mediato da fístula buco-sinusal apresentada neste caso clínico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: determinar as características mecânicas de molas T e T com helicóides, quando da incorporação de variações na liga metálica (aço inoxidável e beta-titânio), na intensidade de dobras de pré-ativação (0º e 40º/180º) e na secção transversal do fio utilizado para a construção destas molas (0,017 x 0,025 e 0,019 x 0,025). METODOLOGIA: foram submetidas ao ensaio mecânico 80 molas para fechamento de espaços, sendo estas centralizadas em um espaço de 21mm. As magnitudes de força horizontal, proporção momento/força e relação carga/deflexão produzidas pelos corpos de prova foram quantificadas utilizando-se um transdutor de momentos acoplado ao módulo indicador digital para extensiometria e adaptado a uma máquina universal de ensaios Instron. As molas foram submetidas a uma ativação total de 5mm, sendo registrados os valores a cada 1mm de ativação. No tratamento estatístico dos dados obtidos, foi realizada a análise de variância, sendo esta complementada pelo teste de comparações múltiplas de Tukey, considerando o nível de significância de 5%. RESULTADOS E CONCLUSÕES: os resultados demonstraram que, de maneira geral, as molas T com helicóides produziram menores magnitudes de força horizontal e relação carga/deflexão do que as molas T. Na presença de pré-ativação, as molas produziram altas proporções momento/força, enquanto, na ausência de dobras de pré-ativação, as mesmas geraram baixas proporções momento/força. Dentre todas as variáveis analisadas, aquela que apresentou uma maior influência na força horizontal e na relação carga/deflexão produzidas pelas molas foi a liga metálica. Já a proporção momento/força mostrou ser influenciada em maior grau pela pré-ativação das molas de fechamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis was carried out to observe whether the application or not of a composite surface sealant (CSS), as well the moment for CSS application were able to reduce marginal microleakage in compactable composite resin restoration. All the preparations were restored with a compactable composite resin. The restored teeth were randomly assessed. G1 (control group): finished and polished; G2: finished, polished, etched and cover with CSS; G3: immediately after the restoration done the CSS was applied, then finished and polished; G4: CSS applied immediately after the restoration was done, the finished and polished, etched, and covered with CSS. The specimens were isolated with nail polish, thermocycled, immersed in aqueous solution of silver nitrate, and followed in a photo developing solution. The microleakage scores obtained from the occlusal and cervical walls were analyzed with the Kruskall-Wallis nonparametric test. No microleakage was found at the enamel margins. Comparing the microleakage scores at dentin/cementum margins (p < 0.05) it was found that G3 (p = 0.0162) and G4 (p = 0.0187) were able to reduce microleakage when compared with group G2. However the results were not statistically different from the control group. The application of CSS was not able to completely eliminate marginal microleakage at the dentin/cementum margins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly radiography was performed to study distal radial physeal closure in ten male and ten female Throughbred horses. The height, thoracic circumference and metacarpus circumference were also measured, Distal radial physeal closure time was sooner in females than males, and took 701 +/- 37 and 748 +/- 55 days respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the effects induced by excited leptons, at the one-loop level, in the anomalous magnetic and weak-magnetic form factors of the leptons. In particular, we compute their contributions to the weak-magnetic moment of the tau lepton, which can be measured on the Z peak, and we compare it with the contributions to g(mu) - 2, measured at low energies.