95 resultados para minutes 25.4

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Over the last three decades, researchers have responded to the demands of industry to manufacture mechanical components with geometrical tolerance, dimensional tolerance, and surface finishing in nanometer levels. The new lapgrinding process developed in Brazil utilizes lapping kinematics and a flat grinding wheel dressed with a single-point diamond dresser in agreement with overlap factor (U(d)) theory. In the present work, the influences of different U(d) values on dressing (U(d) = 1, 3 e 5) and grain size of the grinding wheel made of silicon carbide (SiC = 800, 600 e 300 mesh) are analyzed on surface finishing of stainless steel AISI 420 flat workpieces submitted to the lapgrinding process. The best results, obtained after 10 minutes of machining, were: average surface roughness (Ra) 1.92 nm; 1.19 mu m flatness deviation of 25.4 mm diameter workpieces and mirrored surface finishing. Given the surface quality achieved, the lapgrinding process can be included among the ultra-precision finishing processes and, depending on the application, the steps of lapping followed by polishing can be replaced by the proposed abrasive process.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O objetivo deste estudo foi verificar o efeito da seleção das cargas e do modelo utilizado para a determinação da PC no ergômetro de braço. Participaram do estudo oito voluntários do sexo masculino, que praticavam atividade física regularmente e eram aparentemente saudáveis. Os sujeitos realizaram quatro testes com cargas constantes mantidas até a exaustão voluntária no ergômetro de braço UBE 2462-Cybex. As cargas foram individualmente selecionadas para induzir a fadiga entre 1 e 15 minutos. Para cada sujeito, a determinação da PC foi realizada através de dois modelos lineares: potência-1/tempo e trabalho-tempo. em cada um dos modelos, foram utilizadas todas as potências (1), as três maiores (2) e as três menores (3). As PC encontradas no modelo potência-1/tempo e trabalho-tempo para a condição 3 (177,5 + 29,5; 173,9 + 33,3, respectivamente) foram significantemente menores do que as da condição 2 (190,5 + 23,2; 183,4 + 22,3, respectivamente), não existindo diferenças destas com as da condição 1 (184,2 + 25,4; 176,4 + 28,8, respectivamente). As PC determinadas no modelo potência-1/tempo para as condições 1 e 2 foram significantemente maiores do que as determinadas no modelo trabalho-tempo, não existindo diferenças para a condição 3. Pode-se concluir que as cargas selecionadas e o modelo utilizado interferem na determinação da PC encontrada no ergômetro de braço, podendo interferir no tempo de exaustão durante o exercício submáximo realizado em cargas relativas a este índice.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to compare the power corresponding to maximal lactate steady state determined through continuous (MLSSC) and intermittent protocol with active recovery (MLSSI). Ten trained male cyclists (25 +/- 4 yr., 72.5 +/- 10.6 kg, 178.5 +/- 4.0 cm), performed the following tests on a cycle ergometer: (1) incremental test until voluntary exhaustion to determine the maximal power (Pmax); (2) two to five constant workload tests to determine MLSSC, and; 3) two to three constant workload tests to determine MLSSI, consisting on eight repetitions of four minutes interspersed by two minutes of recovery at 50% Pmax. The MLSSC (273.2 +/- 21.4 W) was significantly lower than MLSSI (300.5 +/- 23.9 W). With base on these data, it can be verified that the intermittent exercise mode utilized in this study, allows an increase of 10% approximately, in the exercise intensity corresponding to MLSS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to compare the power corresponding to maximal lactate steady state determined through continuous (MLSSC) and intermittent protocol with active recovery (MLSSI). Ten trained male cyclists (25 ± 4 yr, 72.5 ± 10.6 kg, 178.5 ± 4.0 cm), performed the following tests on different days on a cycle ergometer: (1) incremental test in order to determine the anaerobic threshold (AT) and maximal power (Pmax); (2) two to five constant workload tests to determine MLSSC, and; 3) two to three constant workload tests to determine MLSSI, consisting on 8 x 4 minutes bouts interspersed by two minutes of active recovery at 50% Pmax (i.e., 46 min of exercise protocol). MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. The workload corresponding to MLSSC (273.2 ± 21.4 W) was significantly lower than that corresponding to MLSSI (300.5 ± 23.9 W). With base on these data, it can be verified that the intermittent exercise mode utilized in this study, allows an increase of 10% approximately, in the exercise intensity corresponding to MLSS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: physical exercise has been recommended as a non-pharmacological, therapeutic strategy in the treatment of important cardiovascular risk factors. Objective: to analyze the impact of an exercise program, tailored to the reality of the Family Health Units (FHU), on body composition, cardiovascular risk factors and Framingham score in obese postmenopausal. Methods: 70 women between 50 and 79 years, sedentary, obese and without menstruating for at least twelve months, were randomly assigned to a trained group (TG) (n = 35) and an untrained (GnT) (n = 35). The GT took 20 weeks of a physical exercise program with three weekly sessions, consisting of monitoring activities and heating (10 minutes), 25 minutes of exercise flexibility and strength, 50 minute walk with intensity between 50-65% of VO2max and 5-minute cool-down. The GnT was instructed to maintain their normal activities. Results: TG showed significant reductions in body mass index (30,1+3,7 vs. 29,3+3,7; p=0,0001), waist circumference (93,3+10,3 vs. 89,1+10,4; p=0,0001), percentage of fat (54,2+2,9 vs. 53,2+3,3; p=0,0001), systolic blood pressure (128,0+14,6 vs. 119,2+10,3; p=0,0001), triglycerides (148,4+66,1 vs. 122,8+40,7; p=0,006), VLDL cholesterol (29,7+13,2 vs. 24,5+8,0; p=0,005) and Framingham score (13,08+4,0 vs. 11,77+4,1; p=0,010). In the untrained group were observed significant increases in the percentage of fat (55,0+4,0 vs. 57,0+3,8; p=0,0001), systolic blood pressure (128,6+10,5 vs. 133,7+12,0; p=0,001), fasting glucose (95,2+18,4 vs. 113,7+28,8; p=0,001) and Framingham score (12,82+3,2 vs. 13,91+4,0; p=0,043), but also decreases levels of HDL cholesterol (55,1+10,5 vs. 51,7+11,0; p=0,017). Conclusion: the exercise program, adapted to the conditions of FHU, was effective in reducing cardiovascular risk factors in obese postmenopausal women served by the SUS program.