102 resultados para matrix effect
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Butyltin (BTs) quantification in environmental matrices can be affected by interfering species found primarily in complex matrices,such as sediment and biota tissues. This study investigated matrix effects in analytical procedures for butyltin (TBT,DBT and MBT) quantification and speciation in sediments and in two fish tissues (gill and liver) by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis. Unlike sediment samples,tissues exhibited a significant matrix effect,thus,the quantification should be made by curve over matrix to avoid quantification errors and loss of analytical accuracy. © 2013 Sociedade Brasileira de Química.
Resumo:
A performance trial was conducted with broiler chicks to Study the effect of phytase (PHY) supplementation in diets formulated With reduced AME, Ca, and P. The nutrient digestibility was determined during the 14- to 21-d and 28- to 35-d periods. The treatments consisted of 3 diets (NC1, NC2. NC3) differing ill nutrient content and each diet with Or without supplemental PHY (NC1, 0 oi 500; NC2, 0 or 750; NC3, 0 or 1,000 U of PHY/kg feed) and I positive control diet (PC). Compared with the PC diet. negative control diets (NC) resulted in lower AME and apparent ileal amino acid digestibility for some amino acids. Phytase Supplementation of the NC diets increased AME. apparent ileal amino acid digestibility, and apparent ileal crude protein digestibility. Phytase addition also increased mineral absorption in 2 1 - and 35-d-old broilers fed NC diets. Reduced nutrient digestibility appears to be I factor in the weight gain and feed intake results. Reducing Ca and P content reduced feed intake in a stepwise fashion in the NC diets. Phytase increased feed intake and generally improved nutrient digestibility, which resulted in an increase in digestible nutrient intake. Averaged across NC diets. PHY improved body weight. Bone-breaking strength was the most consistent predictor of Ca and P reduction. All NC diets had significantly lower bone-breaking strength than the PC. Phytase supplementation of the NC diets gave bone-breaking strengths that were comparable to the PC. Diets with PHY had the highest bioeconomic index.
Resumo:
Gas chromatography with mass spectrometry is frequently used for the quantification of many classes of substances, including alkylphenols. Alkylphenol polyethoxylates are nonionic surfactants used in a wide variety of industrial and consumer applications. Alkylphenol polyethoxylates can degrade to alkylphenols, which are endocrine disruptors. In analytical validation procedures, the most common parameters studied are the detection and quantification limits, linearity, and recovery; however, the matrix effects are sometimes neglected. Although some investigators have evaluated matrix effects, there is no consensus on how to evaluate them during method validation. In this study, the matrix effects of alkylphenol polyethoxylates (nonylphenol monoethoxylate, nonylphenol diethoxylate, octylphenol monoethoxylate, octylphenol diethoxylate) and alkylphenols (nonylphenol and octylphenol) were studied using solid phase extraction and gas chromatography-mass spectrometry analysis. For alkylphenol polyethoxylates, the matrix effects ranged from 16 to 4692%, whereas for alkylphenols (nonylphenol and octylphenol), the effects were insignificant. Therefore, constructing an analytical curve in the matrix for alkylphenol polyethoxylates is essential. © 2013 Copyright Taylor and Francis Group, LLC.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Enzyme-Linked Immunosorbent Assay (ELISA) has been evaluated by analyzing rich-humic water samples from tropical rivers. The samples were spiked with atrazine at ppb level Different pHs (4 to 9) and humic concentrations (2.5 to 40 mg L-1) were investigated. The assay performance showed a strong dependence on the pH values and amount of humic matter at low atrazine concentration. From all the conditions studied the low pH (pH 4) and high humic substances concentrations (40 mg L-1) showed the greatest influence. The IC50 value to control sample (no humic) diminished from 0.28 nmol L-1 to 0.64 nmol L-1 to humic acid solution. This effect is specially noted for the humic acid fractions, since fulvic acid fractions showed no significant change on the immunoassay results. Additionally, it has been demonstrated that at basic pH the matrix effect produced by the natural Brazilian water sample containing humic substances even at 40 mg L-1 disappears. Therefore, the ELISA method used to determine atrazine, can be employed to determine this pesticide in water samples containing humic substances without prior preparation.
Resumo:
Immunochemical methods have increased considerably in the past years, and many examples of small and large scale studies have demonstrated the reliability of the immunotechniques for control and monitoring gf contaminant residues in different kinds of samples. Application of the immunoassay (IA) methods in pesticide residue control is an area with enormous potential for growth. The most extensively studied IA is the enzyme-linked absorbent assay (ELISA), but several other approaches, that include radioimmunoassay and immunoaffinity chromatography, have been also developed recently. In comparison with classical analytical methods, IA methods offer the possibility of highly sensitive, relatively vapid, and cost-effective measurements. This paper introduces the general IAs used until now, focusing on their use in pesticide analysis, and discussing briefly the effects of interferences from solvent residues or matrix components on the IA performance. Numerous immunochemical methods commonly used for pesticide determination in different samples such as food, crop and environmental samples are presented.
Resumo:
Enzyme-linked immunosorbent assays (ELISAs) are the most extensively studied types of immunoassay and their application in pesticide residue monitoring is an area with enormous potential for growth. In comparison with classical analytical methods, ELISA methods offer the possibility of highly sensitive, relatively rapid, and cost-effective measurements. This review introduces the general ELISA formats used, focusing on their use in pesticide analysis. Identifying and studying the effects of interferences in immunoassays is an active area of research and we discuss the matrix effects observed in several studies involving e.g. food, crop and environmental samples. The procedures to eliminate the matrix interferences are briefly discussed. (C) 1998 Elsevier B.V. B.V.
Resumo:
A competitive enzyme-linked immunosorbent assay (ELISA) method for carbaryl quantitation in crop extracts was validated by liquid chromatography (LC) with diode array detection (DAD). For this purpose, six crops (banana, carrot, green bean, orange, peach and potato) were chosen for recovery and reproducibility studies. The general sample preparation included extraction with methanol followed by liquid-liquid partitioning and clean-up on Celite-charcoal adsorbent column of the vegetable extracts. ELISA samples consisted of a diluted LC extract in assay phosphate buffer (pH 7.5). The potential effect of methanol in these samples was evaluated. It was observed that a maximum content of 10% methanol present in the assay buffer could be tolerated without expressive losses in the ELISA performance. Under these conditions, a IC50 similar to 1.48 mu g l(-1) was obtained. A minimum matrix effect with a 1:50 dilution of the methanolic extracts in assay buffer was noticed, except for green bean samples that inhibited completely the assay. For the vegetable extracts, the ELISA sensitivities varied from 3.9 to 5.7 mu g l(-1), and good recoveries (82-96%) with R.S.D.s ranging from 5.7 to 12.1% were found. An excellent correlation between the LC-DAD and ELISA techniques was obtained. The confirmation of the carbaryl in less concentrated samples was achieved by LC-mass spectrometry interfaced with atmospheric pressure chemical ionisation. The [M + H](+)= 202 and [M + H-57](+)=145 ions, equivalent to the protonated molecular and l-naphthol ions, respectively, were used to carbaryl identification in these samples. (C) 1998 Elsevier B.V. B.V. All rights reserved.
Resumo:
A rapid and efficient method is described for the determination of thiabendazole and imazalil residues in lemons (peel and pulp). The procedure is based on the extraction with an hexane:ethyl acetate mixture (1:1, v/v) and gas chromatographic analysis using thermionic specific detection (TSD). The possibility of matrix effect was also studied. Mean recoveries from 8 replicates of fortified samples ranged from 79% to 109%, with relative standard deviation values between 2.4% to 12.8%. The detection and quantification limits of the method were 0.2 mg kg-1 and 0.5 mg kg-1, respectively.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)