86 resultados para mathematical modeling of PTO
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Based on the literature data from HT-29 cell monolayers, we develop a model for its growth, analogous to an epidemic model, mixing local and global interactions. First, we propose and solve a deterministic equation for the progress of these colonies. Thus, we add a stochastic (local) interaction and simulate the evolution of an Eden-like aggregate by using dynamical Monte Carlo methods. The growth curves of both deterministic and stochastic models are in excellent agreement with the experimental observations. The waiting times distributions, generated via our stochastic model, allowed us to analyze the role of mesoscopic events. We obtain log-normal distributions in the initial stages of the growth and Gaussians at long times. We interpret these outcomes in the light of cellular division events: in the early stages, the phenomena are dependent each other in a multiplicative geometric-based process, and they are independent at long times. We conclude that the main ingredients for a good minimalist model of tumor growth, at mesoscopic level, are intrinsic cooperative mechanisms and competitive search for space. © 2013 Elsevier Ltd.
Resumo:
Experiments of continuous alcoholic fermentation of sugarcane juice with flocculating yeast recycle were conducted in a system of two 0.22-L tower bioreactors in series, operated at a range of dilution rates (D (1) = D (2) = 0.27-0.95 h(-1)), constant recycle ratio (alpha = F (R) /F = 4.0) and a sugar concentration in the feed stream (S (0)) around 150 g/L. The data obtained in these experimental conditions were used to adjust the parameters of a mathematical model previously developed for the single-stage process. This model considers each of the tower bioreactors as a perfectly mixed continuous reactor and the kinetics of cell growth and product formation takes into account the limitation by substrate and the inhibition by ethanol and biomass, as well as the substrate consumption for cellular maintenance. The model predictions agreed satisfactorily with the measurements taken in both stages of the cascade. The major differences with respect to the kinetic parameters previously estimated for a single-stage system were observed for the maximum specific growth rate, for the inhibition constants of cell growth and for the specific rate of substrate consumption for cell maintenance. Mathematical models were validated and used to simulate alternative operating conditions as well as to analyze the performance of the two-stage process against that of the single-stage process.
Resumo:
The aim of this paper is to apply methods from optimal control theory, and from the theory of dynamic systems to the mathematical modeling of biological pest control. The linear feedback control problem for nonlinear systems has been formulated in order to obtain the optimal pest control strategy only through the introduction of natural enemies. Asymptotic stability of the closed-loop nonlinear Kolmogorov system is guaranteed by means of a Lyapunov function which can clearly be seen to be the solution of the Hamilton-Jacobi-Bellman equation, thus guaranteeing both stability and optimality. Numerical simulations for three possible scenarios of biological pest control based on the Lotka-Volterra models are provided to show the effectiveness of this method. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The conventional power flow method is considered to be inadequate to obtain the maximum loading point because of the singularity of Jacobian matrix. Continuation methods are efficient tools for solving this kind of problem since different parameterization schemes can be used to avoid such ill-conditioning problems. This paper presents the details of new schemes for the parameterization step of the continuation power flow method. The new parameterization options are based on physical parameters, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and transmission line power losses (real and reactive). The simulation results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are not only preserved but also improved.
Resumo:
In this study, the flocculation process in continuous systems with chambers in series was analyzed using the classical kinetic model of aggregation and break-up proposed by Argaman and Kaufman, which incorporates two main parameters: K (a) and K (b). Typical values for these parameters were used, i. e., K (a) = 3.68 x 10(-5)-1.83 x 10(-4) and K (b) = 1.83 x 10(-7)-2.30 x 10(-7) s(-1). The analysis consisted of performing simulations of system behavior under different operating conditions, including variations in the number of chambers used and the utilization of fixed or scaled velocity gradients in the units. The response variable analyzed in all simulations was the total retention time necessary to achieve a given flocculation efficiency, which was determined by means of conventional solution methods of nonlinear algebraic equations, corresponding to the material balances on the system. Values for the number of chambers ranging from 1 to 5, velocity gradients of 20-60 s(-1) and flocculation efficiencies of 50-90 % were adopted.
Resumo:
The aim of this paper is to study the cropping system as complex one, applying methods from theory of dynamic systems and from the control theory to the mathematical modeling of the biological pest control. The complex system can be described by different mathematical models. Based on three models of the pest control, the various scenarios have been simulated in order to obtain the pest control strategy only through natural enemies' introduction. © 2008 World Scientific Publishing Company.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Detailed monitoring of the groundwater table can provide important data about both short- and long-term aquifer processes, including information useful for estimating recharge and facilitating groundwater modeling and remediation efforts. In this paper, we presents results of 4 years (2002 to 2005) of monitoring groundwater water levels in the Rio Claro Aquifer using observation wells drilled at the Rio Claro campus of São Paulo State University in Brazil. The data were used to follow natural periodic fluctuations in the water table, specifically those resulting from earth tides and seasonal recharge cycles. Statistical analyses included methods of time-series analysis using Fourier analysis, cross-correlation, and R/S analysis. Relationships could be established between rainfall and well recovery, as well as the persistence and degree of autocorrelation of the water table variations. We further used numerical solutions of the Richards equation to obtain estimates of the recharge rate and seasonable groundwater fluctuations. Seasonable soil moisture transit times through the vadose zone obtained with the numerical solution were very close to those obtained with the cross-correlation analysis. We also employed a little-used deep drainage boundary condition to obtain estimates of seasonable water table fluctuations, which were found to be consistent with observed transient groundwater levels during the period of study.
Resumo:
The objective of this study was to estimate the spatial distribution of work accident risk in the informal work market in the urban zone of an industrialized city in southeast Brazil and to examine concomitant effects of age, gender, and type of occupation after controlling for spatial risk variation. The basic methodology adopted was that of a population-based case-control study with particular interest focused on the spatial location of work. Cases were all casual workers in the city suffering work accidents during a one-year period; controls were selected from the source population of casual laborers by systematic random sampling of urban homes. The spatial distribution of work accidents was estimated via a semiparametric generalized additive model with a nonparametric bidimensional spline of the geographical coordinates of cases and controls as the nonlinear spatial component, and including age, gender, and occupation as linear predictive variables in the parametric component. We analyzed 1,918 cases and 2,245 controls between 1/11/2003 and 31/10/2004 in Piracicaba, Brazil. Areas of significantly high and low accident risk were identified in relation to mean risk in the study region (p < 0.01). Work accident risk for informal workers varied significantly in the study area. Significant age, gender, and occupational group effects on accident risk were identified after correcting for this spatial variation. A good understanding of high-risk groups and high-risk regions underpins the formulation of hypotheses concerning accident causality and the development of effective public accident prevention policies.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I- 100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
The venom of Crotalus durissus terrificus snakes presents various substances, including a serine protease with thrombin-like activity, called gyroxin, that clots plasmatic fibrinogen and promote the fibrin formation. The aim of this study was to purify and structurally characterize the gyroxin enzyme from Crotalus durissus terrificus venom. For isolation and purification, the following methods were employed: gel filtration on Sephadex G75 column and affinity chromatography on benzamidine Sepharose 6B; 12% SDS-PAGE under reducing conditions; N-terminal sequence analysis; cDNA cloning and expression through RT-PCR and crystallization tests. Theoretical molecular modeling was performed using bioinformatics tools based on comparative analysis of other serine proteases deposited in the NCBI (National Center for Biotechnology Information) database. Protein N-terminal sequencing produced a single chain with a molecular mass of similar to 30 kDa while its full-length cDNA had 714 bp which encoded a mature protein containing 238 amino acids. Crystals were obtained from the solutions 2 and 5 of the Crystal Screen Kit (R), two and one respectively, that reveal the protein constitution of the sample. For multiple sequence alignments of gyroxin-like B2.1 with six other serine proteases obtained from snake venoms (SVSPs), the preservation of cysteine residues and their main structural elements (alpha-helices, beta-barrel and loops) was indicated. The localization of the catalytic triad in His57, Asp102 and Ser198 as well as S1 and S2 specific activity sites in Thr193 and Gli215 amino acids was pointed. The area of recognition and cleavage of fibrinogen in SVSPs for modeling gyroxin B2.1 sequence was located at Arg60, Arg72, Gln75, Arg81, Arg82, Lis85, Glu86 and Lis87 residues. Theoretical modeling of gyroxin fraction generated a classical structure consisting of two alpha-helices, two beta-barrel structures, five disulfide bridges and loops in positions 37, 60, 70, 99, 148, 174 and 218. These results provided information about the functional structure of gyroxin allowing its application in the design of new drugs.
Resumo:
Objetivou-se com este trabalho determinar o período de convivência anterior à interferência das plantas daninhas (PAI) e o período anterior ao dano no rendimento econômico (PADRE) na cultura do feijão, em diferentes espaçamentos (0,45 e 0,60 m) e densidade de plantas (10 e 15 plantas m-1). Os tratamentos foram constituídos de períodos de convivência entre a cultura e as plantas daninhas (0 a 10, 0 a 20, 0 a 30, 0 a 40, 0 a 50, 0 a 60, 0 a 70 e 0 a 80 dias), mais uma testemunha sem convívio com as plantas daninhas. Adotou-se o delineamento experimental de blocos casualizados, com quatro repetições. Os períodos anteriores à interferência (PAI) da cultura foram de 23, 27, 13 e 19 dias após emergência, e os períodos anteriores ao dano no rendimento econômico (PADRE), de 10, 9, 8 e 8 dias, para os tratamentos com espaçamento de 0,45 m e densidades de semeadura de 10 e 15 plantas m-1 e para aqueles com espaçamento de 0,60 m e densidades de semeadura de 10 e 15 plantas m-1, respectivamente, o que reduziu a produtividade de grãos em 63, 50, 42 e 57%, respectivamente, com a presença das plantas daninhas durante todo o ciclo do feijoeiro.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)