19 resultados para liquid waste
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Blends of synthetic and biodegradable polymers can be important in attaining material plastic degradation in the environment. Biodegradation using soil and chorume (liquid waste from landfill) microorganisms is a promising area these days. This paper intends to study the PVC/PCL blend degradation in soil using aerobic biodegradation (Bartha respirometer). The morphology and structural changes of the blends were studied by FTIR, scanning electron microscopy, differential scanning calorimetry and contact angle measurements. Blend films prepared by the casting of dichloroethane solutions were buried in a Bartha respirometer containing soil and soil plus chorume and kept there for 120 days. During this time CO2 evolution was measured from time to time. The results showed that PCL films degrade faster than PVC/PCL and PVC films.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The cassava processing industry generates wastewater named manipueira with a high organic content. Although considered a pollutant, manipueira can be used as substrate for fermentative processes including the cultivation of Geotrichum fragrans. This aerobic microorganism isolated from cassava wastewater has cyanide resistant respiration. Under cassava wastewater cultivation, G. fragrans produced fruit aroma volatile compounds. This study evaluated volatile compounds produced by G. fragrans in cassava liquid waste. The waste had a sugar composition composed of dextrin (2.6%), maltose (1.4%), sucrose (32.1%), glucose (38.3%), and fructose (25.6%). The average value of total sugars was 58.2 g l(-1), composed of 38.0 g l(-1) reducing and 20.2 g l(-1) non-reducing sugars. The chemical oxygen demand (COD) average value was 60 000 mg l(-1). G. fragrans used sugars (fructose and glucose) for energy generation reducing the COD value of the cassava wastewater by 40%. Biomass production of G. fragrans cultivated for 12 h in natural cassava liquid waste was 12.8 g l(-)1. The volatile compounds identified in the cassava liquid waste after 72 h cultivation were: 1-butanol, 3-methyl 1-butanol (isoamylic alcohol), 2-methyl 1-butanol, 1-3 butanodiol and phenylethanol; ethyl acetate, ethyl propionate, 2-methyl ethyl propionate and 2-methyl propanoic. The effect of substrate supplementation with glucose (50 g l(-1)), fructose (50 g l(-1)) and aqueous yeast extract (200 ml l(-1)) did not affect the qualitative and quantitative profiles of volatile compounds. These results indicate that the carbon (C) source utilized by microorganism was glucose or fructose, while nitrogen (N) supplementation was not necessary because the agent did not exhaust all the nitrogen of the wastewater. (C) 2003 Elsevier B.V. Ltd. All rights reserved.
Comportamento contrátil de barreiras selantes de solo estabilizado para base de lagoas de tratamento
Resumo:
Liners were proposed as subsoil contamination protection devices for waste disposal sites. In the rural environment, they can be used to construct pond bottoms for liquid waste treatment, but the construction needs to be quick and cheap. A good technical solution for these situations is the use of local soil compacted with low quantities of cement or lime, obtaining good properties for this purpose. These barriers need special care about their contraction behavior which may compromise its use. This work shows the results of contraction tests in sandy soil specimens and others stabilized with lime and with cement. Soil structure changes during cure time were checked using electronic scan microscopy. Results show maximum soil contraction of 0.648% for specimen with 14 days cure process. After twenty eight days of cure the contraction values were lower than 0.5%, which classifies the material as of low contraction. Electronic scan image shows significant material structure alteration up to seven days cure. Results show that studied mixtures had appropriate contraction behavior for liner usage.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The organic fraction of urban solid residues disposed of in sanitary landfills during the decomposition yields biogas and leachate, which are sources of pollution. Leachate is a resultant liquid from the decomposition of substances contained in solid residues and it contains in its composition organic and inorganic substances. Literature shows an increase in the use of thermoanalytical techniques to study the samples with environmental interest, this way thermogravimetry is used in this research. Thermogravimetric studies (TG curves) carried out on leachate and residues shows similarities in the thermal behavior, although presenting complex composition. Residue samples were collected from landfills, composting plants, sewage treatment stations, leachate, which after treatment, were submitted for thermal analysis. Kinetic parameters were determined using the Flynn-Wall-Ozawa method. In this case they show little divergence between the kinetic parameter that can be attributed to different decomposition reaction and presence of organic compounds in different phases of the decomposition with structures modified during degradation process and also due to experimental conditions of analysis.
Resumo:
A fast, simple, non-destructive method for the direct screening of polycyclic aromatic hydrocarbons (PAHs) in vegetable oil samples is proposed. The method uses a supercritical fluid extraction (SFE) system coupled on-line with a fluorimetric detector to determine PAHs. This special assembly avoids the main problems encountered in the determination of PAHs in complex matrices such as vegetable oils. PAHs are selectively extracted by using silica gel in the thimble and cleaned up by passage through a C18 column. Interferences are preferentially retained by the silica gel during the SFE process while PAHs are adsorbed in the C18 column and the remainder of the matrix is sent to waste. Finally, the C18 column is purged to remove residual CO2 gas and adsorbed PAHs are recovered by desorption with a solvent. The extracts from positive samples are subsequently analyzed by liquid chromatography (LC) with fluorescence detection. The proposed method allows the confirmation of vegetable oil safety and hence provides a new tool for consumer protection. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Injection metering systems are an important option for the development of pesticide application equipment, with advantages relating to minimising the need for disposal of unused pesticide, improving the ease of cleaning and optimising the accuracy of chemical application. For all injection systems, characteristics such as the steady-state accuracy of delivered dose, dose stability and the time response for dose step changes are related to the ability of the system to operate with different chemical formulations. A system designed to inject liquids should be able to accommodate changes in viscosity and density. The aim of this study was to develop a methodology for testing chemical injection systems using liquids with different viscosities. The experimental arrangement simulating applications with injection metering systems used dye and salt solutions as tracers. Tests were conducted to analyse the influence of salt on the characteristics of the water and a viscous solution. Results showed that the salt interfered with the dye stability in the water solution. In tests with a viscous test liquid, the salt was introduced at different steps during the mixing process, providing four different liquids to be analysed in terms of viscosity, density and pH. Some differences in liquid characteristics were found which could influence the performance of the injection systems.