74 resultados para laser communications with satellites

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. This study aimed to assess the apical surface morphology of maxillary central incisors resected 3.0 mm from the tooth apex using Zekrya burs or Er:YAG laser, with or without subsequent direct Nd:YAG laser irradiation (apical and buccal surfaces) and indirect irradiation (palatal surface).Study design. Forty maxillary central incisors were instrumented and obturated. The roots were divided into 4 groups according to the root resection method (Zekrya bur or Er: YAG laser -1.8 W, 450 mJ, 4 Hz, 113 J/cm(2)) and further surface treatment (none or Nd: YAG laser -2.0 W, 100 mJ, 20 Hz, 124 J/cm(2)). The teeth were prepared for SEM analysis. Scores ranging from 1 to 4 were attributed to cut quality and morphological changes. The data were analyzed by the Kruskal-Wallis test and by Dunn's test.Results. SEM images showed irregular surfaces on the apical portions resected with Zekrya burs, with smear layer and grooves in the resected dentine and slight gutta-percha displacement and plasticization. on the other hand, apicectomies carried out with Er: YAG laser showed morphological changes compatible with ablated dentine, with rough surfaces and craters. In spite of the presence of plasticized gutta-percha, with the presence of bubbles, an irregular adaptation of the filling material to the root walls was also observed. Direct Nd: YAG laser irradiation of the apical and buccal surfaces of the resected roots resulted in areas of resolidification and fusion in the dentine and cementum, with a vitrified aspect; indirect Nd: YAG laser irradiation of the palatal surfaces yielded a lower number of changes in the cementum, with irregular resolidification areas.Conclusions. There were no differences in terms of cut quality between the use of burs and Er: YAG laser or between the 2 surfaces (apical and buccal) treated with Nd: YAG laser with direct irradiation. However, morphological changes were significantly less frequent on surfaces submitted to indirect irradiation (palatal) when compared with those directly irradiated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e77-e82)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to evaluate the surfaces of commercially pure titanium (cp Ti) implants modified by laser beam (LS), without and with hydroxyapatite deposition by the biomimetic method (HAB), without (HAB) and with thermal treatment (HABT), and compare them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS), employing topographical and biomechanics analysis. Methods: Forty-five rabbits received 75 implants. After 30, 60, and 90 days, the implants were removed by reverse torque and the surfaces were topographically analyzed. Results: At 30 days, statistically significant difference (P < 0.05) was observed among all the surfaces and the MS, between HAB/HABT and AS and between HAB and LS. At 60 days, the reverse torque of LS, HAB, HABT, and AS differed significantly from MS. At 90 days, difference was observed between HAB and MS. The microtopographic analysis revealed statistical difference between the roughness of LS, HAB, and HABT when compared with AS and MS. Conclusions: It was concluded that the implants LS, HAB, and HABT presented physicochemical and topographical properties superior to those of AS and MS and favored the osseointegration process in the shorter periods. In addition, HAB showed the best results when compared with other surfaces. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refractive and profilometric measurements of lenses were performed through holography with a photorefractive Bi12TiO20 crystal as the recording medium. Two properly aligned diode lasers emitting in the red region were employed as light sources. Both lasers were tuned in order to provide millimetric and sub-millimetric synthetic wavelengths. The surfaces of the test lens were covered by a 25-μm opaque plastic tape in order to allow the lens profilometry upon illuminating them with a collimated beam. The resulting holographic images appear covered by interference fringes corresponding to the wavefront geometry of the wave scattered by the lens. For refractive index measurement a diffusely scattering flat surface was positioned behind the uncovered lens which was also illuminated by a plane wave. The resulting contour interferogram describes the form of the wavefront after the beam traveled back and forth through the lens. The fringe quantitative evaluation was carried out through the four-stepping technique and the resulting phase map and the Branch-cut method was employed for phase unwrapping. The only non-optical procedure for lens characterization was the thickness measurement, made by a dial caliper. Exact ray tracing calculation was performed in order to establish a relation between the output wavefront geometry and the lens parameters like radii of curvature, thickness and refractive index. By quantitatively comparing the theoretical wavefront geometry with the experimental results relative uncertainties bellow 3% for refractive index and 1 % for focal length were obtained. © 2008 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: the objective of this study was to determine if the zona thinning (ZT) technique improved the rates of implantation and clinical pregnancy for patients aged, greater than or equal to38 years submitted to an ICSI program.Methods: A total of 100 patients submitted to ICSI and aged, greater than or equal to38 years were divided in a prospective and randomized manner into two groups: Group I - patients submitted to ZT (n = 50); a laser diode with 1.48 mum wavelength (Fertilaser) was used for the ZT procedure with 1-2 irradiations of 10 ms applied to four different positions on the zona pellucida (ZP) of each embryo to thin 60-90% of the ZP (each point with a 15-20 mum length of ZT). Group II - patients with no ZT (n = 50). In both groups, embryo transfer was performed on the second or third day.Results: the age of Group I patients (39.8 +/- 1.3) did not differ (p = 0.67) from that of Group II patients (40 +/- 1.9). The number of oocytes retrieved at metaphase II from Group I (6.4 +/- 4.2) and Group II (6.8 +/- 5) was similar (p = 0.94). Normal fertilization rates and cleavage rates were similar (p = 0.78 and p = 0.63, respectively) for Group I (71.5 +/- 22% and 96.7 +/- 11%) and Group II (73.5 +/- 19.7% and 96 +/- 11%, respectively). The number of embryos transferred was similar (p = 0.53) for the two groups (Group I = 3.1 +/- 1.3; Group II = 2.9 +/- 1.1). The thickness of the ZP of Group I embryos (16.9 +/- 2.4 mum) did not differ (p = 0.97) from that of Group II embryos (16.9 +/- 2.3 mum). The rates of embryo implantation and clinical pregnancy per embryo transfer were similar (p = 0.67, p = 0.61) for Group I (7 and 16%, respectively) and for Group II (8.2 and 22%, respectively).Conclusions: These results suggest that ZT in the population aged, 38 years may have no impact on ICSI success rates. However, this conclusion is limited to a situation in which length of the laser ZT was less than or equal to 20 mum and the laser was applied to four different positions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface and biomechanical analysis of titanium implant surfaces modified by laser beam with and without hydroxyapatite. Titanium implants with 3 different surfaces were inserted into the tibias of 30 rabbits: group I (GI) machined surface (control group), group II irradiated with laser (GII), and group III irradiated with laser and hydroxyapatite coating applied-biomimetic method (GIII). Topographical analysis with scanning electron microscopy was made before surgery in the tibia. These rabbits were distributed into 2 periods of observation: 4 and 8 weeks postsurgery, after which biomechanical analysis (removal torque) was conducted. Statistical analysis used the Student-Newman-Keuls method. Surface showed roughness in GII and GIII. Biomechanical analysis demonstrated values with significant differences in GII and GIII. Titanium implants modified by laser irradiation can increase osseointegration during the initial phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ranula is a mucous extravasation cyst which appears as a swelling in the submental and submandibular regions. Several surgical techniques to manage ranula have been described in the literature, these techniques include the CO2 laser radiation excision. Four patients were treated for intraoral ranula in the floor of the mouth by marsupialization with carbon dioxide laser radiation with defocused beam, continuous mode and 4 watts of power. There were no complications and no recurrences have occurred to date. The results showed that carbon dioxide laser radiation gives optimal results with no need for suture and good wound healing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been suggested that low-level laser therapy (LLLT) can modulate inflammatory processes. The aim of this experiment was to investigate what effects red laser irradiation with two different wavelengths (660 nm and 684 nm) on carrageenan-induced rat paw edema and histology. Thirty two male Wistar rats were randomly divided into four groups. One group received a sterile saline injection, while inflammation was induced by a sub-plantar injection of carrageenan (1 mg/paw) in the three other groups. After 1 h, LLLT was administered to the paw in two of the carrageenan-injected groups. Continuous wave 660 nm and 684 nm red lasers respectively with mean optical outputs of 30 mW and doses of 7.5 J/cm(2) were used. The 660 nm and 684 nm laser groups developed significantly (P < 0.01) less edema (0.58 ml [SE +/- 0.17] ml and 0.76 ml [SE +/- 0.10] respectively) than the control group (1.67 ml [SE +/- 0.191) at 4 h after injections. Similarly, both laser groups showed a significantly lower number of inflammatory cells in the muscular and conjunctive sub-plantar tissues than the control group.We conclude that both 660 nm and 684 nm red wavelengths of LLLT are effective in reducing edema formation and inflammatory cell migration when a dose of 7.5 J/cm(2) is used. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet laser instrumentation of root surfaces on the morphology of fibroblasts from continuous lineage. Method and materials: Dentinal slices with 4 mm(2) of surface area were obtained from teeth extracted for severe periodontal involvement. Specimens were assigned to one of three treatment groups: group 1, application of the laser with an energy level of 250 mJ at 103 pulses per second; group 2, application of the laser with an energy level of 80 mJ at 166 pulses per second; and group 3, similar to group 2, but with concomitant water irrigation of the device. The specimens were incubated in multiwell plates containing cell culture media. After 24 hours, the specimens were submitted to routine preparation for scanning electron microscopy. Three independent and blind examiners used photomicrographs to evaluate the morphology of the fibroblasts: 0 = without cells; 1 = flat cells; 2 = round cells; and 3 = combination of round and flat cells. Results: Statistical analysis indicated that there were significant differences among treatment groups and that group 3 was significantly different from groups 1 and 2. Conclusion: There was no difference between groups 1 and 2 in the morphology of fibroblasts. Laser instrumentation with concomitant irrigation impaired the adhesion of fibroblasts to dentinal surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet laser instrumentation of root surfaces on the morphology of fibroblasts from continuous lineage. Method and materials: Dentinal slices with 4 mm2 of surface area were obtained from teeth extracted for severe periodontal involvement. Specimens were assigned to one of three treatment groups: group 1, application of the laser with an energy level of 250 mJ at 103 pulses per second; group 2, application of the laser with an energy level of 80 mJ at 166 pulses per second; and group 3, similar to group 2, but with concomitant water irrigation of the device. The specimens were incubated in multiwell plates containing cell culture media. After 24 hours, the specimens were submitted to routine preparation for scanning electron microscopy. Three independent and blind examiners used photomicrographs to evaluate the morphology of the fibroblasts: 0 = without cells; 1 = flat cells; 2 = round cells; and 3 = combination of round and flat cells. Results: Statistical analysis indicated that there were significant differences among treatment groups and that group 3 was significantly different from groups 1 and 2. Conclusion: There was no difference between groups 1 and 2 in the morphology of fibroblasts. Laser instrumentation with concomitant irrigation impaired the adhesion of fibroblasts to dentinal surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (R a = 1.38 ± 0.23 μm) when compared to that of the MS (R a = 0.33 ± 0.06 μm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants. © 2009 Sociedade Brasileira de Pesquisa Odontológica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have used our new pulsed CO(2) laser, operating both on regular and hot bands, to excite the (13)CD(3)OH methanol isotopomer. This has lead to the observation of 13 new high-threshold far-infrared laser emissions (also identified as terahertz laser lines), with frequencies in the range between 24.11 and 102.56 cm(-1) (0.72-3.07 THz). The absorption transitions leading to these new FIR laser emissions have been located by observing the optoacoustic absorption spectra around the CO(2) emissions. Here, we present these new far-infrared laser lines, characterized in wavelength, polarization, offset relative to the center of the pumping CO(2) laser transition, relative intensity, and optimum operation pressure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hemangioma of urinary tract are unusual, being about 2 % of all hemangiomas. We present a case of a glans penis hemangioma. There is controversy concerning their treatment and outcome. Our patient was treated with a Neodymium : Yag laser irradiation, with complete morphological recuperation.