101 resultados para incident angle

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stoichiometric Ba1-xSrxTiO3 (BST; x = 0.4) thin films were prepared by the polymeric precursor method. High quality polycrystalline films of BST with low roughness (approximate to 3 nm) were obtained from a Pt/Ti/SiO2/Si substrate deposited by spin-coating technique. Microstructure and morphological evaluation were done using grazing incident X-ray diffraction (GIXRD), scanning electron microscopy (SEM), and atomic force microscopy (AFM). Grazing incident angle XRD characterization of these films showed that BST phase crystallizes at 600 degrees C from an inorganic amorphous matrix. No intermediate crystalline phase was identified. A linear relationship between roughness and grain size was observed. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of polymeric precursors was employed in preparing SrTiO3 thin films by dip coating using Si (111) as substrate. Crack free films were obtained after sintering at temperatures ranging from 550 to 1000°C. The microstructure, characterized by SEM, shows the development of dense polycrystalline films with smooth surface and mean grain size of 52 nm, for films sintered at 1000°C. Grazing incident angle XRD characterization of these films shows that the SrTiO3 phase crystallizes from an inorganic amorphous matrix. No intermediate crystalline phase was identified.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A polymeric precursor solution was employed in preparing SrBi2Nb2O9 (SBN) powder and thin films dip coated onto Si(100) substrate. XRD results show that the SBN perovskite phase forms at temperatures as low as 600°C through an intermediate fluorite phase. This fluorite phase is observed for samples heat-treated at temperatures of 400 and 500°C. After heat treatment at temperatures ranging from 300 to 800°C, thin films were shown to be crack free. Grazing incident angle XRD characterization shows the occurrence of the fluorite intermediate phase for films also. The thickness of films, measured by MEV, was in the order of 80-100 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation has been made on the monthly and annual average diurnal evolution of the hourly diffuse radiation as well as its radiometric fractions on surfaces inclined at 12.85, 22.85 and 32.85° to face North, in climate conditions of Botucatu, São Paulo, Brazil (22.85° S and 48.43° W). Measurements were made between 04/1998 to 08/2001 for 22.85°; 09/2001 to 02/2003 for 12.85° and 01/2004 to 12/2007 for 32.85°, with concomitant measures in the horizontal. For all surfaces the diffuse radiation was obtained from different method. Assessment has been performed as well on the radiometric fractions obtained from the ratio of diffuse radiation and global radiation (KDH and KDβ) and between radiation and diffuse radiation at the top of the atmosphere (KʹDH and KʹDβ) for the horizontal and tilted surfaces in hourly partition. The diffuse radiation levels were dependent on variations in precipitation and cloudiness. There was an increase in the differences between the diffuse radiation and the radiometric fractions with the increment of the angle, and in horizontally, which affected higher levels of diffuse radiation in spring and summer. The values of KDH and KDβ present in an inverse behavior were compared to diffuse radiation and theydecreased in the southern passage due to the increase of the direct component in the total of incident radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliou-se a evolução anual das componentes global, direta e difusa da radiação solar incidente em superfícies inclinadas a 12,85; 22,85 e 32,85º, com face voltada ao Norte, em Botucatu-SP. Foram obtidas frações radiométricas para cada componente da radiação nas superfícies supracitadas, através de razões com a radiação global e a do topo da atmosfera. A sazonalidade foi avaliada através das médias mensais dos valores diários. As medidas ocorreram entre 04/1998 e 07/2001, em 22,85º; 08/2001 e 02/2003, em 12,85º; e de 03/2003 a 12/2007, em 32,85º, com medidas concomitantes no plano horizontal (referência). Os níveis das radiações global e direta nos planos inclinados foram inferiores no período de verão e superiores entre os equinócios, quando comparadas ao plano horizontal. A radiação difusa nas superfícies inclinadas foi inferior na maioria dos meses, com perdas de até 65%. Ocorreu uma tendência de aumento das diferenças entre as superfícies horizontal e inclinada com o incremento do ângulo em todas as componentes e frações da radiação incidente. A evolução anual das precipitações pluviométricas e da razão de nebulosidade afetou diretamente a transmissividade atmosférica das componentes direta e difusa na região.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistics equations and validations with groups of annual and monthly data were evaluated for global, direct and diffuse solar radiation components incident on the tilted surface to 12.85, 22.85 and 32.85 degrees with the face North, in climate and geographical conditions of Botucatu, SP. It was employed the fractions of three components of extraterrestrial radiation in correlation with the coefficient clearness index horizontal plane, in a database of April/1998 to December/2007, whose measures at different periods in three inclinations, however concomitant to the horizontal plane. Increasing the angle of the surface led to increased scattering of the daily values of clearness index for inclined and horizontal surfaces. In annual groups, the lower performances were observed in the estimation of inclined daily diffuse radiation, with maximum Root Mean Square Error to 3.89 MJ m(-2) d(-1) (43.65%) and adjustments around 62%. In estimates of global and direct components of solar radiation on inclined planes, both annual and monthly equations can be applied, with performance dependents to climatic conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small-angle X-ray scattering (SAXS) and electron paramagnetic resonance (EPR) have been carried out to investigate the structure of the self-aggregates of two phenothiazine drugs, chlorpromazine (CPZ) and trifluoperazine (TFP), in aqueous solution. In the SAXS studies, drug solutions of 20 and 60 mM, at pH 4.0 and 7.0, were investigated and the best data fittings were achieved assuming several different particle form factors with a homogeneous electron density distribution in respect to the water environment. Because of the limitation of scattering intensity in the q range above 0.15 angstrom(-1), precise determination of the aggregate shape was not possible and all of the tested models for ellipsoids, cylinders, or parallelepipeds fitted the experimental data equally well. The SAXS data allows inferring, however, that CPZ molecules might self-assemble in a basis set of an orthorhombic cell, remaining as nanocrystallites in solution. Such nanocrystals are composed of a small number of unit cells (up to 10, in c-direction), with CPZ aggregation numbers of 60-80. EPR spectra of 5- and 16-doxyl stearic acids bound to the aggregates were analyzed through simulation, and the dynamic and magnetic parameters were obtained. The phenothiazine concentration in EPR experiments was in the range of 5-60 mM. Critical aggregation concentration of TFP is lower than that for CPZ, consistent with a higher hydrophobicity of TFP. At acidic pH 4.0 a significant residual motion of the nitroxide relative to the aggregate is observed, and the EPR spectra and corresponding parameters are similar to those reported for aqueous surfactant micelles. However, at pH 6.5 a significant motional restriction is observed, and the nitroxide rotational correlation times correlate very well with those estimated for the whole aggregated particle from SAXS data. This implies that the aggregate is densely packed at this pH and that the nitroxide is tightly bound to it producing a strongly immobilized EPR spectrum. Besides that, at pH 6.5 the differences in motional restriction observed between 5- and 16-DSA are small, which is different from that observed for aqueous surfactant micelles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surfaces of silicon wafers implanted with N and C, respectively, and aluminum 5052 implanted with N alone by plasma immersion ion implantation WHO were probed by a nanoindentor and analyzed by the contact-angle method to provide information on surface nanohardness and wettability. Silicon nitride and silicon carbide are important ceramic materials for microelectronics, especially for high-temperature applications. These compounds can be synthesized by high-dose ion implantation. The nanohardness of a silicon sample implanted with 12-keV nitrogen PIII (with 3 X 10(17) cm(-2) dose) increased by 10% compared to the unimplanted sample, in layers deeper than the regions where the formation of the Si,N, compound occurred. A factor of 2.5 increase in hardness was obtained for C-implanted Si wafer at 35 keV (with 6 X 10(17) cm(-2) dose), again deeper than the SiC-rich layer, Both compounds are in the amorphous state and their hardness is much lower than that of the crystalline compounds, which require an annealing process after ion implantation. In the same targets, the contact angle increased by 65% and 35% for N- and C-implanted samples, respectively. Compared to the Si target, the nitrogen PIII-irradiated Al 5052 (wish 15 keV) showed negligible change in its hydrophobic character after ion implantation. Its near-surface nanohardness measurement showed a slight increase for doses of 1 X 10(17) cm(-2). We have been searching for an AlN layer of the order of 1000 A thick, using such a low-energy PIII process, but oxide formation during processing has precluded its synthesis. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: as oclusopatias estão entre os principais problemas de saúde bucal em todo o mundo, juntamente com a cárie dentária e a doença periodontal, e vários índices têm sido utilizados para registrá-las. OBJETIVOS: verificar a prevalência de oclusopatias utilizando a Classificação de Angle e o Índice de Estética Dentária (DAI), sua severidade e a necessidade de tratamento ortodôntico registradas pelo DAI, e comparar os resultados de ambos os índices, visando correlacionar o padrão dos dados coletados e a viabilidade de utilizá-los de forma conjunta. MÉTODOS: a amostra consistiu de 734 escolares com idade de 12 anos, de ambos os sexos, da rede pública do município de Lins/SP. Foram realizados exames nos pátios das escolas com utilização de sondas IPC a olho nu. RESULTADOS: pela Classificação de Angle, encontrou-se 33,24% das crianças com oclusão normal e 66,76% com má oclusão. Pelo DAI, observou-se que 65,26% das crianças apresentavam-se sem anormalidades ou com más oclusões leves. A má oclusão definida esteve presente em 12,81%, a má oclusão severa foi observada em 10,90% e a muito severa ou incapacitante em 11,03%. A maioria das crianças (70,57%) apresentou relação molar normal, e o overjet maxilar anterior foi a alteração mais frequentemente observada. No cruzamento dos índices houve semelhanças e divergências. CONCLUSÃO: o DAI não foi sensível a alguns problemas de oclusão detectados pela Classificação de Angle, e a recíproca foi verdadeira, demonstrando que ambos os índices possuem pontos distintos na detecção das oclusopatias, podendo ser utilizados de forma reciprocamente complementar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: o presente trabalho tem o propósito de apresentar uma revisão da literatura acerca do tratamento da má oclusão de Classe II, divisão 1 de Angle, tendo a protrusão maxilar como o principal componente dessa má oclusão, durante a fase de crescimento e desenvolvimento craniofacial. Serão apresentadas as características de cada um desses aparelhos, os seus componentes, a forma adequada de utilização, os seus mecanismos de ação e, principalmente, os seus efeitos em todo o complexo dentofacial. CONCLUSÃO: nos casos em que se verifica apenas a protrusão maxilar, sem envolvimento mandibular, e se faz necessário o controle vertical, pode ser indicado o AEB, conjugado ao aparelho removível derivado do aparelho preconizado por Thurow. Já nas situações de combinação da protrusão maxilar com a retrusão mandibular, uma opção de tratamento é o ativador combinado à ancoragem extrabucal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo foi realizado com o propósito de avaliar respostas cefalométricas ao tratamento com aparelho extrabucal de Kloehn associado ao aparelho fixo edgewise convencional. Telerradiografias iniciais (T1) e finais (T2) de dois grupos de 30 pacientes tratados com estes aparelhos foram selecionadas e definidas pelo índice cefalométrico de Jarabak para determinação do padrão esquelético craniofacial. Os grupos foram denominados favorável (hipodivergente) e desfavorável (hiperdivergente). A idade média, no início do tratamento, foi de 11,03 anos e final de 14,72 com o tempo médio de tratamento de 3,6 anos para o grupo favorável. No grupo desfavorável a idade inicial foi de 11,51 anos e final de 15,17 anos com tempo médio de tratamento de 3,4 anos. Foi utilizado um sistema de análise de resposta de tratamento em coordenadas X e Y representativos dos movimentos dentários e das bases ósseas decompondo-os em seus vetores horizontais e verticais. Os resultados e respostas do tratamento foram analisados e comparados entre os grupos favorável e desfavorável utilizando o teste t-Student. Os resultados mostraram não haver diferenças estatisticamente significantes na resposta cefalométrica no tratamento com o aparelho extrabucal de Kloehn associados ao aparelho fixo edgewise quanto aos padrões faciais favorável e desfavorável. O tratamento promoveu uma restrição do deslocamento anterior maxilar e um menor deslocamento anterior mandibular. Quanto à movimentação dentária maxilar, houve uma restrição do movimento mesial e extrusivo dos molares superiores no grupo favorável, enquanto que o movimento dos dentes inferiores foi mínimo no sentido anterior e vertical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and unpredictable mandibular fractures to treat. Despite the evolution in the treatment of maxillofacial trauma and fixation methods, no single treatment modality has been revealed to be ideal for mandibular angle fractures. Several methods of internal fixation have been studied with great variation in complications rates, especially postoperative infections. Recently, new studies have shown reduction of postsurgical complications rates using three-dimensional plates to treat mandibular angle fractures. Nevertheless, only few surgeons have used this type of plate for the treatment of mandibular angle fractures. The aim of this clinical report was to describe a case of a patient with a mandibular angle fracture treated by an intraoral approach and a three-dimensional rectangular grid miniplate with 4 holes, which was stabilized with monocortical screws. The authors show a follow-up of 8 months, without infection and with occlusal stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)