82 resultados para high linear

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The determination of leukocyte alkaline phosphatasd (LAP) is used as an aid to diagnose many diseases in the laboratory. For example, it can be used to distinguish chronic myeloid leukemia (CML) from other myeloproliferative disorders (particularly myelofibrosis and polycythemia) and leukemoid reactions (LR). Traditionally, this test is performed with the use of subjective cytochemical assays that assign a score to the level of LAP. Here we present a nonsubjective, quantitative, sensitive, and inexpensive chemiluminescent technique that determines LAP based on the commercial reagent Immulite (R) (AMPPD). To validate this methodology, intact leukocytes obtained from 32 healthy subjects, nine CML patients, and nine LR patients were submitted to the optimized protocol. By measuring the light emission elicited by four concentrations of neutrophils, we were able to estimate the activity of LAP per cell (the slope of the curve obtained by linear regression). A high linear correlation was found between the chemiluminescent result (slope) and the cytochemical score. The slope for healthy individuals ranged between 0.61 and 8.49 (10(-5) mV.s/cell), with a median of 2.04 (10(-5) mV.s/cell). These results were statistically different from those of CML patients (range = 0.07-1.75, median = 0.79) and LR patients (range = 3.84-47.24, median 9.58; P < 0.05).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cada vez mais é crescente o uso do GPS (Global Positioning System ) em estudos da atmosfera terrestre. Neste artigo, a atmosfera superior da Terra, denominada ionosfera, foi estudada durante um período de alta atividade solar (ano de 2001) usando dados de receptores GPS de dupla freqüência localizados na região brasileira, pertencentes à RBMC (Rede Brasileira de Monitoramento Contínuo). A partir dos dados GPS foram calculados os valores de TEC (Total Electron Content - Conteúdo Total de Elétrons) da ionosfera. Adicionalmente foram incluídos no estudo dados de freqüência crítica da camada F2 advinda de Digissondas localizadas em São Luís/MA (3ºS; 44ºW) e Cachoeira Paulista/SP (22ºS; 45ºW), para fins de comparação. de uma forma geral, os resultados mostraram maiores valores de TEC durante os meses próximos aos equinócios e menores durante os meses de inverno. Quanto à variação diária do TEC, os menores valores foram verificados por volta das 4-6 HL (Hora Local) e os maiores durante o período da tarde, com valores um pouco maiores para São Luís. O segundo pico da anomalia equatorial foi verificado em Cachoeira Paulista nos meses próximos aos equinócios e verão. Na maioria dos meses, uma alta correlação linear foi verificada quando realizada a comparação entre os valores de freqüência crítica da camada F2 e os de TEC, principalmente para São Luís.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciência dos Materiais - FEIS

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper discusses a design approach for a high-Q low-sensitivity OTA-C biquad bandpass section. An optimal relationship is established between transconductances defining the differencebeta - gamma in the Q-factor denominator, setting the Q-sensitivity to tuning voltages around unity. A 30-MHz filter was designed based on a 0.35 mum CMOS process and V-DD=3.3 V. A range of circuit simulation supports the theoretical analysis. Q-factor spans from 20.5 to 60, while ensuring filter stability along the tuning range. Although a triode-operating OTA is used, the procedure can be extended to other types of transconductor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the use of probit and logit link functions for the genetic evaluation of early pregnancy using simulated data. The following simulation/analysis structures were constructed: logit/logit, logit/probit, probit/logit, and probit/probit. The percentages of precocious females were 5, 10, 15, 20, 25 and 30% and were adjusted based on a change in the mean of the latent variable. The parametric heritability (h²) was 0.40. Simulation and genetic evaluation were implemented in the R software. Heritability estimates (ĥ²) were compared with h² using the mean squared error. Pearson correlations between predicted and true breeding values and the percentage of coincidence between true and predicted ranking, considering the 10% of bulls with the highest breeding values (TOP10) were calculated. The mean ĥ² values were under- and overestimated for all percentages of precocious females when logit/probit and probit/logit models used. In addition, the mean squared errors of these models were high when compared with those obtained with the probit/probit and logit/logit models. Considering ĥ², probit/probit and logit/logit were also superior to logit/probit and probit/logit, providing values close to the parametric heritability. Logit/probit and probit/logit presented low Pearson correlations, whereas the correlations obtained with probit/probit and logit/logit ranged from moderate to high. With respect to the TOP10 bulls, logit/probit and probit/logit presented much lower percentages than probit/probit and logit/logit. The genetic parameter estimates and predictions of breeding values of the animals obtained with the logit/logit and probit/probit models were similar. In contrast, the results obtained with probit/logit and logit/probit were not satisfactory. There is need to compare the estimation and prediction ability of logit and probit link functions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive, precise, and specific high-performance liquid chromatographic (HPLC) method was developed for the assay of gatifloxacin (GATX) in raw material and tablets. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was carried out by reversed-phase chromatography on a C18 absorbosphere column (250 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of acetic acid 50/o--acetonitrile-methanol (70 + 15 + 15, v/v/v) pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 287 nm. The calibration graph for GATX was linear from 4.0 to 14.0 mu g/mL. The interday and intraday precisions (relative standard deviation) were less than 1.05%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simple and rapid procedures were developed for the quantification of amfepramone hydrochloride and diazepam and mazindol and diazepam in tablets using high performance liquid chromatography (HPLC) with UV detection. These techniques provided conditions for the separation of each active ingredient from the complex matrices of the dosage forms by dilution or extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (70:10:20, v/v/v) as a mobile phase, Radial-Pak C-18 column (100 x 8 mm id, 4 mu m), a column temperature of 25+/-1 degrees C and detection at 255 nm. The calibration curves were linear over a wide concentration range (100-1000 mu g.mL(-1) to amfepramone hydrochloride and mazindol and 10-100 mu g.mL(-1) to diazepam) with good correlation factors of 0.9978, 0.9956 and 0.9997 for amfepramone hydrochloride, mazindol, and diazepam, respectively.Mean recoveries obtained from the two kinds of samples ranged from 83.2 to 102.5%, with coefficients of variation ranging from 1.0 to 6.1.These results demonstrated the efficiency of the proposed methods, as well as advantages such as simplicity and short duration of analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanol-water (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 mu g/mL. The values for interday and intraday precision (relative standard deviation) were < 1 %. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Engineers often face the challenge of reducing the level of vibrations experienced by a given payload or those transmitted to the support structure to which a vibrating source is attached. In order to increase the range over which vibrations are isolated, soft mounts are often used in practice. The drawback of this approach is the static displacement may be too large for reasons of available space for example. Ideally, a vibration isolator should have a high-static stiffness, to withstand static loads without too large a displacement, and at the same time, a low dynamic stiffness so that the natural frequency of the system is as low as possible which will result in an increased isolation region. These two effects are mutually exclusive in linear isolators but can be overcome if properly configured nonlinear isolators are used. This paper is concerned with the characterisation of such a nonlinear isolator comprising three springs, two of which are configured to reduce the dynamic stiffness of the isolator. The dynamic behaviour of the isolator supporting a lumped mass is investigated using force and displacement transmissibility, which are derived by modelling the dynamic system as a single-degree-of-freedom system. This results in the system dynamics being approximately described by the Duffing equation. For a linear isolator, the dynamics of the system are the same regardless if the source of the excitation is a harmonic force acting on the payload (force transmissibility) or a harmonic motion of the base (displacement transmissibility) on which the payload is mounted. In this paper these two expressions are compared for the nonlinear isolator and it is shown that they differ. A particular feature of the displacement transmissibility is that the response is unbounded at the nonlinear resonance frequency unless the damping in the isolator is greater than some threshold value, which is not the case for force transmissibility. An explanation for this is offered in the paper. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os atributos físicos do solo têm se mostrado de grade interesse para a agricultura contemporânea, uma vez que refletem decisivamente sobre a produtividade vegetal. em 2006, no campus da Faculdade de Engenharia de Ilha Solteira, Unesp, analisouse a produtividade do feijoeiro (PG) no sistema plantio direto irrigado, a resistência mecânica do solo à penetração (RP), a densidade do solo (DS) e as umidades gravimétrica (UG) e volumétrica (UV) em profundidade, num LATOSSOLO VERMELHO Distroférrico. O objetivo foi determinar as correlações lineares e espaciais, entre os atributos estudados, visando selecionar um indicador da qualidade física do solo de boa representatividade para a PG. Foi instalada a malha, para a coleta de dados contendo 135 pontos amostrais, numa área de 7.500 m². A correlação linear entre a produtividade de grãos com os atributos do solo foi baixa. As de melhor correlação com a PG foram a DS1 e RP1. Contudo, do ponto de vista espacial, houve significativa correlação inversa entre a PG e DS1. Portanto, no presente trabalho, dentre os atributos estudados, a DS, avaliada na camada de 0-0,10 m, apresentou-se como o melhor indicador da qualidade física de um Latossolo de Selvíria, quando destinado à produtividade de grãos de feijão.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Soil porosity influences plant development since root growth and crop yield are determined by the root depth. The objective of this study was to investigate the linear and spatial variability and correlations between common bean yield and soil porosity. The bean grain yield of the irrigated cultivar Carioca IAC was analyzed in the growing season 2004/2005, in Selviria-MS, as well as macroporosity (MA), microporosity (MI) and total porosity (TP), in a Dystroferric Red Latosol, at four depths: 1 (0.0-0.10 m), 2 (0.10-0.20 M), 3 (0.20-0.30 m) and 4 (0.30-0.40 m). Soil and plant data were collected in a geostatistical grid with 135 points spaced 10 m apart, covering an area of 50 x 150 m. The data of the studied attributes did not vary randomly and the values were intermediate to low. They followed well-defined spatial standards, reaching between 11.70-104.40 m. on the other hand, the linear correlation between the plant and soil attributes was low, due to the high number of observations. Grain yield had the best linear correlations with MA1b, MI1 and TP3. From the spatial point of view, the inverse correlation between PG and #TP2 was outstanding. At the sites where #TP2 diminished (0.030-0.045 m(3) m(-3)) the yield varied from 2,173 to 3,529 kg ha(-1) and where it increased (0.045-0.076 m(3) m(-3)), the yield was between 1,630 and 2,173 kg ha(-1). Therefore, the total soil porosity, evaluated in the 0.10-0.20 m layer (#TP2), indicated the importance of the contact root/soil and was in turn a satisfactory indicator of soil physical quality, with a view to the grain yield of irrigated common bean.