58 resultados para great saphenous vein
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]
Resumo:
Aim. Superficial thrombophlebitis (ST) ascending the lower limbs is a common disease, which may be associated with deep vein thrombosis (DVT) and pulmonary embolism (PE). The aim of this study was to investigate the prevalence of DVT and PE as complications of ascending ST of the lower limbs in the great saphenous vein (GSV) or SSV (SSV) and probable risk factors.Methods. For this study 60 consecutive patients were enrolled with ascending ST of the GSV or SSV, seen between 2000 and 2003 at a public hospital in Botucatu, SP, Brazil. All patients were assessed clinically, by venous Duplex scanning of the lower limbs to confirm ST and test for DVT, and by means of pulmonary scintigraphy to test for PE.Results. In 13 ST cases (21.67%) there was concomitant DVT and 17 ST patients (28.33%) also had PE. Eleven patients had a clinical status suggestive of DVT, but only in eight of these (61.5%), this clinical diagnosis was confirmed. Fourteen patients had a clinical status suggestive of PE, and this diagnosis was confirmed in six cases (35.30%). ST patients who also had DVT and/or PE were given anticoagulant treatment with heparin and warfarin. None of the variables studied was predictive of DVT or PE (P>0.05). However, the presence of varicose veins reduced the risk of patients having DVT (relative risk=9.09; 95%CI:1.75 - 50.00 and P=0.023).Conclusion. The prevalence rates of PE (28.3%) and DVT (21.6%) were elevated in this sample of ascending ST cases, indicating a need for detailed assessment of patients for signs of these complications, including for therapeutic management decision making. [Int Angiol 2009;28:400-8]
Resumo:
Superficial nerve injuries are very common during varicose vein surgery. In contrast, deep nerve injuries are rare and reported especially when surgery involves the small saphenous vein (SSV). The deep motor nerves most commonly injured are the tibial nerve and the peroneal nerve, which are directly or indirectly affected by extrinsic compression, stretching, or healing process involvement. In this report, two cases of common fibular nerve injury after SSV stripping are described, including treatment used and patient outcomes. Nerve damage mechanisms, anatomy, and prevention strategies are also discussed. In conclusion, fibular nerve damage may occur during SSV stripping. Preventive measures include careful preoperative ultrasonographic investigation of the anatomy of the vein, determining location of the saphenopopliteal joint, and careful dissection far from fibular nerve and restricted to the popliteal fossa.
Resumo:
The present study was undertaken to look for the effect of chloroethylclonidine (CEC) on prejunctional alpha-2 autoreceptors of the canine saphenous vein. The effect was tested on tritium overflow evoked by electrical stimulation from tissues preloaded with 0.2 μM 3H- norepinephrine. Yohimbine (3-300 nM) and CEC (1-125 μM) increased and UK- 14,304 reduced the overflow of tritium evoked by 300 pulses (1 Hz). The maximal increase of tritium overflow caused by yohimbine was much higher than that caused by CEC: 3.82 and 1.74 times, respectively. CEC (5 μM) abolished both the inhibition caused by UK-14,304 and the enhancement of tritium overflow caused by yohimbine. However, when CEC was added after yohimbine, it reduced the electrically evoked overflow of tritium, the maximal effect being a reduction of tritium overflow by 35%. Prazosin (1-100 nM) did not change either the inhibitory effect of UK-14,304 or the facilitatory effect of CEC. These results suggest that CEC acts on two different subtypes of prejunctional alpha-2 autoreceptors; on one of them it acts as an antagonist and increases the electrically evoked overflow of tritium (and inhibits both the effect of UK-14,304 and yohimbine); on the other it acts as an agonist and reduces the electrically evoked overflow of tritium. Alternatively, one can admit that CEC is able to inhibit alpha-2 autoreceptors, which causes an increase of the transmitter release, and to activate a nonadrenergic inhibitory receptor thus causing a reduction of the transmitter release.
Resumo:
A veia safena magna autóloga é o melhor substituto arterial nas revascularizações dos membros inferiores, importante na revascularização do miocárdio e pode ser utilizada nas cirurgias do sistema venoso e nos traumas das extremidades. A fleboextração aumenta os riscos de lesões linfáticas e neurológicas. Assim, no tratamento das varizes primárias dos membros inferiores por meio da cirurgia ou de outras técnicas, a preservação da safena é recomendável se ela for normal ou apresentar alterações que ainda permitam sua preservação pela correção da causa desencadeante. Tal correção pode ser feita por técnicas cirúrgicas. Entre elas, a cura hemodinâmica da insuficiência venosa em ambulatório (CHIVA) tem mostrado bons resultados. Recentemente, um ensaio clínico randomizado e controlado foi publicado comprovando sua eficácia. Outra técnica bastante utilizada é a da ligadura rasante da junção safenofemoral + crossectomia + ligadura das tributárias de crossa, com a qual se tem obtido resultados contraditórios. Finalmente, as técnicas que corrigem a insuficiência da safena reparando as valvas ostial e pré-ostial (valvoplastia externa) são mais fisiológicas. Um ensaio clínico internacional multicêntrico, randomizado e controlado, testando um novo dispositivo, está sendo realizado, com resultados iniciais favoráveis. Este estudo pretende fazer uma revisão sobre as técnicas utilizadas na preservação da safena magna.
Resumo:
Background: Cardiovascular diseases remain leaders as the major causes of mortality in Western society. Restoration of the circulation through construction of bypass surgical treatment is regarded as the gold standard treatment of peripheral vascular diseases, and grafts are necessary for this purpose. The great saphenous vein is often not available and synthetic grafts have their limitations. Therefore, new techniques to produce alternative grafts have been developed and, in this sense, tissue engineering is a promising alternative to provide biocompatible grafts. This study objective was to reconstruct the endothelium layer of decellularized vein scaffolds, using mesenchymal stem cells (MSCs) and growth factors obtained from platelets. Methods: Fifteen nonpregnant female adult rabbits were used for all experiments. Adipose tissue and vena cava were obtained and subjected to MSCs isolation and tissue decellularization, respectively. MSCs were subjected to differentiation using endothelial inductor growth factor (EIGF) obtained from human platelet lysates. Immunofluorescence, histological and immunohistochemical analyses were employed for the final characterization of the obtained blood vessel substitute. Results: The scaffolds were successfully decellularized with sodium dodecyl sulfate. MSCs actively adhered at the scaffolds, and through stimulation with EIGF were differentiated into functional endothelial cells, secreting significantly higher quantities of von Willebrand factor (0.85 μg/mL; P < .05) than cells cultivated under the same conditions, without EIGF (0.085 μg/mL). Cells with evident morphologic characteristics of endothelium were seen at the lumen of the scaffolds. These cells also stained positive for fascin protein, which is highly expressed by differentiated endothelial cells. Conclusions: Taken together, the use of decellularized bioscaffold and subcutaneous MSCs seems to be a potential approach to obtain bioengineered blood vessels, in the presence of EIGF supplementation. © 2013 Society for Vascular Surgery.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.
Resumo:
OBJETIVO: Analisar, comparativamente, a obtenção minimamente invasiva com o uso do MINI-HARVEST® e com instrumental tradicional adaptado. MÉTODO: de junho de 1996 a janeiro de 1999, 63 pacientes submetidos à cirurgia de revascularização do miocárdio tiveram suas veias safenas retiradas segundo técnica minimamente invasiva. Nos 30 primeiros pacientes da série utilizou-se método de visão direta com auxílio de dois afastadores de Langenbeck, e nos 33 restantes utilizou-se o MINI-HARVEST®. RESULTADOS: A idade média dos pacientes era de 61 ± 8,75 anos, sendo 52 homens e 11 mulheres. Quarenta e cinco pacientes eram diabéticos, 45 apresentavam sobrepeso/obesidade, 25 eram tabagistas ativos, 32 apresentavam história pregressa de infarto do miocárdio. O tempo médio de retirada da veia safena com afastadores Langenbeck foi de 34,2 ± 8,14 minutos e com o MINI-HARVEST® de 39,20 ± 9,12 minutos. A extensão de veia retirada foi similar nos dois grupos, variando de 10 a 30 cm. Houve uma deiscência superficial no grupo com afastadores de Langenbeck. Houve necessidade de reversão para método tradicional de retirada em dois casos do grupo MINI-HARVEST® e um do grupo Langenbeck. A incidência de infarto transoperatório foi 4,5% (três) no grupo Langenbeck e 3,1%(dois) no grupo MINI-HARVEST®. CONCLUSÕES: Podemos concluir que o método de obtenção de veia safena minimamente invasivo sob visão direta é efetivo e seguro, tanto com o uso de instrumentos tradicionais adaptados para este fim, como com afastadores especialmente constituídos, ressaltando-se que o MINI-HARVEST® dispensa a presença de um auxiliar.
Resumo:
O emprego da trombectomia na angioplastia primária demonstra bons resultados clínicos e angiográficos imediatos, por meio de redução da embolização distal e do fenômeno do no-reflow e otimização da perfusão miocárdica. Essa técnica, principalmente usada em artérias coronárias, em raras oportunidades é descrita quando empregada em pontes de safena aortocoronarianas. Relatamos o caso de um paciente de 67 anos com infarto agudo do miocárdio relacionado a oclusão de ponte de safena e submetido a trombectomia com bons resultados.
Resumo:
The coronary sinus was investigated in 34 normal adult dogs, in order to verify its formation, tributaries, length and the valves, as well as the relationship of the venous walls to the epicardium and to the myocardium. The valve of the coronary sinus was observed in only 4 cases (1.7 %). In 30 cases (98.3 %) the ostium of the coronary sinus was lacking a valve. The valve of Vieussens double, was found at the level of the transition between the great cardiac vein and the coronary sinus, as well as others parietal venous valves. A comparison with the human pattern was made, particularly regarding the action of the valve of the coronary sinus and the formation of the sinus.
Resumo:
The authors studied the formation, tributaries, lenght and the ostium of the coronary sinus, as well as the relationship of the venous walls to the myocardium and to the epicardium. The observations were made out of 143 hearts of subjects of different ages, and it was found that the most frequent display of the coronary sinus valve was a semilunar form (52 adults, 15 youngsters, 2 children, 3 newborn); it was also found valves in a cribiform or septal form. The absence of the valve of coronary sinus was noted in 53 cases (42 adults, 9 youngsters, 2 newborn). The valve of Vieussens was found, in some cases, at the level of the transition between the great cardiac vein and the coronary sinus, as well as others single or double parietal venous valves. The action of the valve of coronary sinus is also discussed by the authors.
Resumo:
The coronary sinusin fetuses ofzebu-crossedbovinesis studiedbyvasculardissectionsand radiographs. There aretwopredominant patterns offormation of thecoronary sinus: bydirect continuation of theleft azygos vein, from thegreat cardiac vein, and by theunion of thegreat cardiac veinwith theleft azygos vein. The first patternappeared in17animals,while thesecondpatternformation of thecoronary sinuswas found in13animals. Regarding sex there was nodifference between thepatterns shown.The main tributariesof the coronaryveinincattleare representedby the followingvessels: great cardiac vein, middle cardiac vein, veins of the faceof theleft ventricle andatrium, obliqueveinof left atrium.The great cardiac veinisseen asadirect continuation of theinterventricular veinparaconal. From these results, it appears thatthe standardvenousfetalbovineheartis predominantlyconfluentthe coronary sinus. Onlyasmall number ofvesselsare directlyconfluentto theright atrium ofbovine heart.
Resumo:
Mesenchymal stem cells (MSCs) are adult multipotent cells with fibroblastoid morphology and adherent to plastic. Furthermore, they can be obtained from different sources. Besides bone marrow, these cells are taken from umbilical cord blood, umbilical vein, saphenous vein, peripheral blood, arteries, liver and fetal pancreas, placenta, dental pulp and adipose tissue. MSCs derived from adipose tissue are important because of the abundant number of cells that can be obtained from this tissue, easy access and little discomfort to the patient. This study compared two techniques for obtaining MSCs from adipose tissue: mechanical dissociation (MD) and enzymatic digestion (ED). We also analyzed the inter-species cross-reactions using commercial monoclonal antibodies directed against surface antigens of stem cells from different species: mouse, horse, rabbit, monkey and human. We found that MD technique is favorable in relation to ED within 15 days of culture, and ED is more efficient in the first days of culture. The data also showed that MD causes less damage to cellular DNA. About inter-species cross-reactions, the monoclonal antibody A69 directed against stem cells from rabbits, which can be used in veterinary medicine, particularly in research involving horses