51 resultados para floating wire
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The end magnets of the IFUSP race-track microtron booster, second stage of the electron accelerator under construction at the Linear Accelerator Laboratory, are presented. They deflect, focus and return the beam to the accelerating section. Details about the project are discussed, Poisson code was used to give the final geometry of the end magnets. The end magnets incorporate auxiliary pole pieces (clamps) which create a reverse fringe field region that avoids the beam vertical defocusing and reduces the horizontal displacement produced by extended fringe fields (EFF). The small gap height used for the clamps provided reverse field distributions with fringe fields of short extensions, avoiding the traditional use of inactive clamps. Measurements and calculations concerning particle trajectories and reverse field distribution are presented. The floating wire technique, employing an original procedure to register orbits, was used to corroborate the calculated beam trajectories and represents a good experimental option in the lack of the accelerator beam. The experimental results showed agreement of about 0.1% with the calculations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A 15-month-old DSH cat was presented with facial deformity secondary to multiple oral and maxillofacial fractures after being struck by an automobile. Multiple wires and dental acrylics were used for fracture repair.
Resumo:
A new methodology for tree seedling production (Aquaforest system) based on a continuous floating subirrigation system was developed and tested using creeks with different nutrient levels. Eucalyptus grandis seedlings were produced in water from polluted and clean creeks, and compared to conventional tree nursery production. The growth variables analyzed in the seedling phase were: survival, height, diameter, shoot and root dry weight, leaf area, and root/shoot ratio. Water and substrate were analyzed, as well as leaf nutritional status. Plant survival was 100% in all treatments. Height and diameter were greater in the higher nutrient water treatment. Leaf area and dry weight of plants produced in the higher nutrient water treatment were similar to those of the control. The results showed that polluted water can represent a good nutrient source. The preliminary results show that the Aquaforest system can be a viable alternative for tree seedling production. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded neutral and another in delta, in parallel to the load. The mathematical development has been proposed in previous work [3]. In this paper, however, the methodology was adapted to accept different power factors for the system to be compensated. on the other hand, the determination of the compensation susceptances is based on the instantaneous values of the load currents. The results are obtained using the MatLab - Simulink environment.
Resumo:
The objective of the study was to evaluate the effect of different concentrations of nitrogen and phosphorus on the growth of the free-floating aquatic macrophytes Eichhornia crassipes, Pistia stratiotes, and Salvinia molesta. The plants were cultured in 2,000-l outdoor concrete tanks. Triplicate tanks, with a continuous flow of effluent from culture ponds containing Nile tilapia, were used for each plant type (n = 3). The plant material was collected monthly from 0.25 m(2) floating quadrats, at the two ends of the tanks (higher nutrient concentrations near the inflow and lower nutrient concentrations near the outflow). In low nutrient concentrations, the maximum relative growth rates (RGRs) for E. crassipes (0.016/day) and P. stratiotes (0.016/day) were significantly lower (P <= 0.05) than for S. molesta (0.029/day). There were no significant differences between the RGRs of S. molesta in the different nutrient concentrations. Eichhornia crassipes and P. stratiotes had their growth limited by nitrogen and phosphorus concentrations. The increase in plant density during the experiment probably also affected the growth of these species. In this context, E. crassipes and P. stratiotes can cause problems in nutrient-rich waterbodies, but under these experimental conditions their growth was limited by nitrogen and/or phosphorus concentrations. The growth of S. molesta was not influenced by the different nutrient concentrations.
Resumo:
We comment on the recent results [Phys. Rev. B 70, 235314 (2004)] showing the dispersion relations of single-particle and collective excitations in quantum wires in the presence of the Rashba spin-orbit interaction (SOI). We claim that those calculations performed in the absence of SOI, and used as a strong reference to the interacting case, are unlikely to be correct. We show the correct omega-q plane of the system in the absence of Rashba SOI.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In the present work we study a long superconducting wire with a columnar defect in the presence of an applied magnetic field. The cross section of the cylinder is assumed to be circular. The field is taken uniform and parallel to the cylinder axis. We use the London theory to investigate the vortex lattice inside the wire. Although this theory is valid in the limit of low vortex density, that is, when the nearest neighbor vortex distance is much larger than the coherence length, we can obtain a reasonable qualitative description of lattice properties. We calculate: (1) the vortex lattice structure using the simulated annealing technique; (2) the magnetization curve as a function of the applied field.
Resumo:
The neutral wire in most existing power flow and fault analysis software is usually merged into phase wires using Kron's reduction method. In some applications, such as fault analysis, fault location, power quality studies, safety analysis, loss analysis etc., knowledge of the neutral wire and ground currents and voltages could be of particular interest. A general short-circuit analysis algorithm for three-phase four-wire distribution networks, based on the hybrid compensation method, is presented. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. A generalised fault analysis method is applied to the distribution network for conditions with and without embedded generation. Results obtained from several case studies on medium- and low-voltage test networks with unbalanced loads, for isolated and multi-grounded neutral scenarios, are presented and discussed. Simulation results show the effects of neutrals and system grounding on the operation of the distribution feeders.
Resumo:
This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded neutral and other in delta, in parallel to the load. The mathematical development has been proposed in previous work [3]. In this paper, however, the determination of the compensation susceptances is based on the instantaneous values of load currents. The results are obtained using the MatLab-Simulink enviroment
Resumo:
The neutral wire in most power flow software is usually merged into phase wires using Kron's reduction. Since the neutral wire and the ground are not explicitly represented, neutral wire and ground currents and voltages remain unknown. In some applications, like power quality and safety analyses, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of special interest. In this paper, a general power flow algorithm for three-phase four-wire radial distribution networks, considering neutral grounding, based on backward-forward technique, is proposed. In this novel use of the technique, both the neutral wire and ground are explicitly represented. A problem of three-phase distribution system with earth return, as a special case of a four-wire network, is also elucidated. Results obtained from several case studies using medium- and low-voltage test feeders with unbalanced load, are presented and discussed.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We investigate the flux penetration patterns and matching fields of a long cylindrical wire of circular cross section in the presence of an external magnetic field. For this study we write the London theory for a long cylinder both for the mixed and Meissner states, with boundary conditions appropriate for this geometry. Using the Monte Carlo simulated annealing method, the free energy of the mixed state is minimized with respect to the vortex position and we obtain the ground state of the vortex lattice for N=3 up to 18 vortices. The free energy of the Meissner and mixed states provides expressions for the matching fields. We find that, as in the case of samples of different geometry, the finite-size effect provokes a delay on the vortex penetration and a vortex accumulation in the center of the sample. The vortex patterns obtained are in good agreement with experimental results.