269 resultados para endosseous implants

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Commercially pure titanium alloys are currently used as metallic biomaterials in implantology. Corrosion phenomena appear to play a decisive role in metallic implant long-term behavior. Thus, the goal of this study was to examine the genotoxic potential of corrosion eluates obtained from dental implants using Chinese ovary hamster cells in vitro by the single-cell gel (comet) assay. This technique detects deoxyribonucleic acid strand breaks in individual cells in alkaline conditions.Materials and Methods: the materials tested included 3 dental implants commercially available. Each of the tested materials was corroded in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. The Chinese ovary hamster cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37 degrees C.Results: None of the eluates was found to exhibit genotoxicity, regardless of the type of dental implant used.Conclusion: the results suggest that all dental implants tested in this study did not induce deoxyribonucleic acid breakage as depicted by the single-cell gel (comet) assay.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: This study tested the hypothesis that early integration of plateau root form endosseous implants is significantly affected by surgical drilling technique.Materials and Methods: Sixty-four implants were bilaterally placed in the diaphysial radius of 8 beagles and remained 2 and 4 weeks in vivo. Half the implants had an alumina-blasted/acid-etched surface and the other half a surface coated with calcium phosphate. Half the implants with the 2 surface types were drilled at 50 rpm without saline irrigation and the other half were drilled at 900 rpm under abundant irrigation. After euthanasia, the implants in bone were nondecalcified and referred for histologic analysis. Bone-to-implant contact, bone area fraction occupancy, and the distance from the tip of the plateau to pristine cortical bone were measured. Statistical analyses were performed by analysis of variance at a 95% level of significance considering implant surface, time in vivo, and drilling speed as independent variables and bone-to-implant contact, bone area fraction occupancy, and distance from the tip of the plateau to pristine cortical bone as dependent variables.Results: The results showed that both techniques led to implant integration and intimate contact between bone and the 2 implant surfaces. A significant increase in bone-to-implant contact and bone area fraction occupancy was observed as time elapsed at 2 and 4 weeks and for the calcium phosphate-coated implant surface compared with the alumina-blasted/acid-etched surface.Conclusions: Because the surgical drilling technique did not affect the early integration of plateau root form implants, the hypothesis was refuted. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69: 2158-2163, 2011

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the possibility of obtaining guided bone regeneration using a poly-tetrafluoroethylene (PTFE) nonporous barrier for 2 endosseous implants, partially inserted in tibiae of rabbits.Materials and Methods: Histologic characteristics of the interface between titanium implants (one group with titanium plasma-coated implants and the other group with acid-treated surfaces) and of the regenerated bone were also studied. Twenty screw-vent implants were placed in tibiae of 5 male New Zealand rabbits, 2 at the right side and 2 at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. At the experimental group the implants were with a PTFE nonporous barrier, whereas no barriers were used in contralateral implants. Animals were sacrificed 3 months after surgery and biopsy specimens were evaluated histologically and histomorphometrically under light microscopy. Student's t test was used for statistical analysis.Results: The histologic measurements showed a mean gain in bone height of 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control group, for the titanium plasma-spray and acid-treated implant surfaces, respectively.Conclusion: The results of the investigation revealed that the placement of implants protruding 3 nun from crestal bone defects may result in vertical bone augmentation using a nonporous PTFE barrier. (Implant Dent 2009;18:182-191)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Calcium phosphate-based bioactive ceramics in various physical and chemical formulations have been extensively utilized as biomaterials for bone regeneration/conduction. However, the determination of their in vivo temporal behavior from the short to long term in humans has been a challenge due to the lack of physical reference for morphologic and morphometric evaluation. The present study evaluated bone morphology and morphometry (bone-to-implant contact [BIC]) around plasma-sprayed hydroxyapatite (PSHA)-coated endosseous implants that were retrieved due to prosthetic reasons while successfully in function at the posterior region of the jaws from as early as 2 months to ~13 years after a 6-month healing period after placement. Bone morphology was evaluated by light microscopy, and BIC was determined using computer software. Irrespective of the time in vivo, lamellar bone was observed in close contact with the implant PSHA-coated surface and between plateaus. BIC ranged from ~35-95%, was highly directional, and Haversian-like osteonic morphology between plateaus was observed for most implants. The PSHA coating was present with little variation in thickness between the samples retrieved regardless of time in vivo. © 2010 by Begell House, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Previous studies have pointed out that the mere elevation of the maxillary sinus membrane promotes bone formation without the use of augmentation materials. Purpose: This experimental study aimed at evaluating if the two-stage procedure for sinus floor augmentation could benefit from the use of a space-making device in order to increase the bone volume to enable later implant installation with good primary stability. Materials and Methods: Six male tufted capuchin primates (Cebus apella) were subjected to extraction of the three premolars and the first molar on both sides of the maxilla to create an edentulous area. The sinuses were opened using the lateral bone-wall window technique, and the membrane was elevated. One resorbable space-making device was inserted in each maxillary sinus, and the bone window was returned in place. The animals were euthanatized after 6 months, and biopsy blocks containing the whole maxillary sinus and surrounding soft tissues were prepared for ground sections. Results: The histological examination of the specimens showed bone formation in contact with both the schneiderian membrane and the device in most cases even when the device was displaced. The process of bone formation indicates that this technique is potentially useful for two-stage sinus floor augmentation. The lack of stabilization of the device within the sinus demands further improvement of space-makers for predictable bone augmentation. Conclusions: It is concluded that (1) the device used in this study did not trigger any important inflammatory reaction; (2) when the sinus membrane was elevated, bone formation was a constant finding; and (3) an ideal space-making device should be stable and elevate the membrane to ensure a maintained connection between the membrane and the secluded space. © 2009 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The biological principles of osseointegration caused the rehabilitation treatment with osseointegrated implant become a safe, well alternative accepted by the dental community for the high success rate, allowing the preparation of functional and aesthetic prostheses in edentulous and partial patients. We passed the initial phase of functional vision for an aesthetic approach, too, depending on the demands of the patient and the quest for excellence by professionals. Over these last years, implant treatment has undergone many changes in surgical and prosthetic protocols. The less invasive surgical techniques and the development of restorative materials, especially ceramics allow the prosthetic rehabilitation of high functional quality and aesthetics. The installation of implants in sockets immediately after extraction of teeth involved by fracture, periodontal disease, endodontic lesions, is part of the arsenal of techniques for rehabilitating a number of advantages that we get to the outcome of multidisciplinary treatment. For this, we must consider several criteria in its planning as a fundamental unit, adjacent teeth, multiple losses, system, form and number of implants, type of retention of the prosthesis components, the patient expectation of the outcome perspective, gingival biotype, standard of ridge resorption, the smile line, etc. occlusal analysis. With the three-dimensional placement of the implant can immediately join the biological processes of repair of the socket, implant osseointegration, speeding treatment time. Much has been made by companies in the surface treatment of endosseous implants to be osseointegration shortened and restorative procedures started earlier, bringing benefits to the patient and professional. Among the main advantages we can emphasize the preservation of the structures adjacent to the teeth replaced, minor resorption of bone tissue involved... (Complete abstract click electronic access below)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate the correlations between clinical-radiographical aspects and histomorphometric-molecular parameters of endosseous dental implant sites in humans. Material and methods: The study sample consisted of bone implant sites from the jawbones of 32 volunteers, which were classified according to two different systems: (1) based only on periapical and panoramic images (PP); (2) as proposed by Lekholm & Zarb (L&Z). Bone biopsies were removed using trephine during the first drilling for implant placement. Samples were stained with haematoxylin-eosin (HE), and histomorphometric analysis was performed to obtain the following parameters: trabecular thickness (Tb.Th), trabecular number, bone volume density (BV/TV), bone specific surface (BS/BV), bone surface density and trabecular separation (Tb.Sp). In addition, immunohistochemistry analysis was performed on bone tissue samples for the proteins, Receptor activator of nuclear factor kappa-B (RANK), RANK ligand (RANKL), osteoprotegerin (OPG) and Osteocalcin (OC). Also, the determination of the relative levels of gene expression was performed using Reverse transcription-real-time Polymerase Chain Reaction (RT-PCR). Results: PP and L&Z classification systems revealed a moderate correlation with BV/TV, BS/BV, Tb.Th and Tb.Sp. L&Z's system identified differences among bone types when BV/TV, BS/BV, Tb.Th and Tb.Sp were compared. A weak correlation between PP/L&Z classifications and the expression of bone metabolism regulators (RANK, RANKL, OPG e OC) was found. The analysis of mRNA expression showed no difference between the bone types evaluated. Conclusions: Our results suggest that PP and L&Z subjective bone-type classification systems are related to histomorphometric aspects. These data may contribute to the validation of these classifications. Bone remodelling regulatory molecules do not seem to influence morphological aspects of the jawbone © 2011 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this literature review is to discuss the use of dental implants in growing patients and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended to wait for the completion of dental and skeletal growth, except for severe cases of ectodermal dysplasia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The oral rehabilitation by dental implants in patients with diabetes remains a controversial issue. The aim of this study was to evaluate the influence of diabetes mellitus and insulin therapy on the bone healing around dental implants using torque removal. Twenty-seven rabbits were randomly divided into 3 groups with 9 animals each: control (C) group, induced diabetic (D) group, and insulin-treated diabetic (ITD) group (10 U/day). After 1 week, one implant was inserted at the tibial metaphysis of the animals. The glucose levels were periodically evaluated through the glucose-oxidase enzymatic method. The animals were killed at 4, 8, and 12 weeks after surgery and the biomechanical test was performed using a torque manometer. Statistically significant differences regarding the removal torque of the implant could not be found at 4 weeks (P = 0.2) among groups. Group C showed statistically higher values than groups D and ITD at the experimental periods of 8 (P = 0.0001 and P = 0.0002, respectively) and 12 weeks (P = 0.0053 and P = 0.001, respectively). There were no statistical differences between D and ITD groups in any of the experimental periods. Diabetes mellitus has negatively influenced the mechanical retention of implants placed at the tibial metaphysis of rabbits. Therapy with insulin did not induce any changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (R a = 1.38 ± 0.23 μm) when compared to that of the MS (R a = 0.33 ± 0.06 μm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants. © 2009 Sociedade Brasileira de Pesquisa Odontológica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article reports the 9-year clinical outcome of the two-stage surgical rehabilitation of a severely atrophic edentulous maxilla with a metal-resin fixed denture supported by implants anchored in the zygomatic bone and the maxilla. After clinical and radiographic examination, zygomatic implants were inserted bilaterally and four standard implants were placed in the anterior region of the maxilla. Six months later, the implants were loaded with a provisional acrylic resin denture, and the definitive implant-supported metal-resin fixed denture was provided 1 year after implant placement. After 9 years of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. In the present case, the rehabilitation of severe maxillary atrophy using the zygomatic bone as a site for implant anchorage provided good long-term functional and esthetic results. Therefore, with proper case selection, correct indication, and knowledge of the surgical technique, the use of zygomatic implants associated with standard implants offers advantages in the rehabilitation of severely resorbed maxillae, especially in areas with inadequate bone quality and volume, without needing an additional bone grafting surgery, thereby shortening or avoiding hospital stay and reducing surgical morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules.Methods In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into ultrasound'' and control'' groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light.Results Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization.Conclusion The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.