38 resultados para direct digital radiograph
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.
Resumo:
O objetivo deste estudo foi avaliar a influência do cetoprofeno sobre o processo de reparação óssea em tíbias de ratos, por meio da análise da densidade óptica digital. Vinte ratos da linhagem Wistar foram divididos em 2 grupos: um grupo controle (sem tratamento) e um grupo tratado com cetoprofeno. Os procedimentos experimentais consistiram de: anestesia, cirurgia, administração do cetoprofeno e exame radiográfico. As imagens radiográficas foram adquiridas empregando-se o sensor digital Visualix GX-S-HDI™ e um aparelho de raios X. As radiografias foram realizadas nos períodos baseline (inicial), 7, 14, 21 e 30 dias pós-operatório, sendo a densidade óptica (DO) avaliada por meio do sistema Vix winTM 1.4. Os valores médios da leitura da do obtidos foram analisados estatisticamente por meio de ANOVA e teste de Tukey com nível de significância de 5%. No grupo controle, houve diferença estatisticamente significante (p=0,001) entre o tempo e a DO, enquanto no grupo tratado com cetoprofeno a diferença não foi estatisticamente significante (p=0,100). O grupo controle apresentou as menores proporções de do (%) no 1º e 7º dias e as maiores proporções de do (%) no 14º, 21º e 30º dias, com diferença estatisticamente significante (p=0,001). Não houve diferença estatisticamente significante (p=0,100) entre as proporções médias de do (%) no grupo tratado, independentemente do período de avaliação. Os achados deste trabalho sugerem que houve influência do cetoprofeno sobre o processo de reparo ósseo, uma vez que na primeira semana o medicamento proporcionou aumento na densidade óptica e provocou atraso na neoformação óssea após o 21º dia.
Resumo:
Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
Resumo:
The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/ onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems.
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.
Resumo:
The radiopacity of esthetic restorative materials has been established as an important requirement, improving the radiographic diagnosis. The aim of this study was to evaluate the radiopacity of six restorative materials using a direct digital image system, comparing them to the dental tissues (enamel-dentin), expressed as equivalent thickness of aluminum (millimeters of aluminum). Five specimens of each material were made. Three 2-mm thick longitudinal sections were cut from an intact extracted permanent molar tooth (including enamel and dentin). An aluminum step wedge with 9 steps was used. The samples of different materials were placed on a phosphor plate together with a tooth section, aluminum step wedge and metal code letter, and were exposed using a dental x-ray unit. Five measurements of radiographic density were obtained from each image of each item assessed (restorative material, enamel, dentin, each step of the aluminum step wedge) and the mean of these values was calculated. Radiopacity values were subsequently calculated as equivalents of aluminum thickness. Analysis of variance (ANOVA) indicated significant differences in radiopacity values among the materials (P<0.0001). The radiopacity values of the restorative materials evaluated were, in decreasing order: TPH, F2000, Synergy, Prisma Flow, Degufill, Luxat. Only Luxat had significantly lower radiopacity values than dentin. One material (Degufill) had similar radiopacity values to enamel and four (TPH, F2000, Synergy and Prisma Flow) had significantly higher radiopacity values than enamel. In conclusion, to assess the adequacy of posterior composite restorations it is important that the restorative material to be used has enough radiopacity, in order to be easily distinguished from the tooth structure in the radiographic image. Knowledge on the radiopacity of different materials helps professionals to select the most suitable material, along with other properties such as biocompatibility, adhesion and esthetic.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objectives:This study evaluated the influence of ovariectomy 8 weeks after implant placement on bone integrated to titanium implants.Materials and methods:Thirty-eight female rats were submitted to a titanium implant at the tibiae proximal methaphysis. After a healing period of 8 weeks the animals were randomly divided into three groups: control (CTL-10 animals), sham-operated (SHAM-14 animals) and ovariectomy (OVX-14 animals). The CTL group was then sacrificed in order to confirm integration of the implant. The SHAM group was submitted to fictitious surgery and the OVX group was submitted to bilateral ovariectomy. After 12 weeks post-implant placement, the SHAM and OVX groups were sacrificed. In order to confirm the systemic osteopenia in rats, a dual-energy X-ray absorptiometry (DXA) was performed. For the evaluation of bone density, digital radiographs were taken. The grey level of the bone adjacent to implant was measured using image software and the bone density was calculated at six points on both sides of the implant.Results:Densitometry measurements of the femur confirmed systemic bone mass loss in the OVX group. Individualized bone analyses of different regions surrounding the implant showed a significantly lower radiographic bone density (P < 0.05) in the cancellous region of the OVX group (77.48 +/- 23.39 grey levels) when compared with the CTL and SHAM groups (91.61 +/- 32.10 and 102.57 +/- 32.50 grey levels, respectively).Conclusions:The present study showed a decrease of the radiographic bone density in the cancellous region of bone around titanium implants placed 8 weeks before ovariectomy in rats.
Resumo:
This article presents a new method to detect damage in structures based on the electromechanical impedance principle. The system follows the variations in the output voltage of piezoelectric transducers and does not compute the impedance itself. The proposed system is portable, autonomous, versatile, and could efficiently replace commercial instruments in different structural health monitoring applications. The identification of damage is performed by simply comparing the variations of root mean square voltage from response signals of piezoelectric transducers, such as lead zirconate titanate patches bonded to the structure, obtained for different frequencies of the excitation signal. The proposed system is not limited by the sampling rate of analog-to-digital converters, dispenses Fourier transform algorithms, and does not require a computer for processing, operating autonomously. A low-cost prototype based on microcontroller and digital synthesizer was built, and experiments were carried out on an aluminum structure and excellent results have been obtained. © The Author(s) 2012.
Resumo:
Pós-graduação em Odontologia - FOAR