42 resultados para direct comparison method
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Both adalimumab [ADA] and infliximab [IFX] seem to be effective in the prevention of early postoperative endoscopic recurrence [EPER] after ileocaecal resection in Crohn's disease [CD] patients. There is lack of data with direct comparison between the two agents in the postoperative scenario. The aim of this study was to compare the rates of EPER in patients treated with ADA and IFX after ileocaecal resection for CD. This was a multicentre retrospective analysis of EPER rates in CD patients after ileocaecal resections, from seven referral centres in three countries. Endoscopic recurrence was defined as Rutgeerts' score ≥ i2. The patients were allocated according to treatment to two groups: ADA or IFX. The EPER rates were compared between the two treatment groups. Among the 168 patients included in the database, 96 received anti-tumour necrosis factor [TNF] agents after resection [37 in the ADA and 59 in the IFX groups] and were included in this comparative study. The groups were comparable in all baseline characteristics, mainly age, gender, previous resections, perianal CD, and mono or combination therapy. EPER was identified in 9/37 [24.32%] in the ADA group vs 16/59 [27.12%] in the IFX group [p = 0.815]. In this retrospective direct comparison between ADA and IFX therapy after ileocaecal resection, there was no significant difference between the two anti-TNF agents in terms of EPER rates. However, prospective randomised studies are needed to confirm these data and better define the role of each agent in the prevention of EPER.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background:It has been stated that mandibular overdentures are more satisfactory than conventional dentures, but problems relating to the use of retrospective ratings, lack of control group and sequential provision of treatment may compromise the findings.Objective:To establish a comparison between treatment with conventional complete dentures and implant-retained overdentures in elderly patients by conducting a literature review.Materials and methods:A search of English language peer-review literature was completed using Medline up to 2008 focusing on evidence-based research. Randomised clinical trials (RCTs) and longitudinal prospective studies were favoured in the review, using a general hierarchical classification. Articles that did not focus exclusively on the comparison of patient satisfaction between complete dentures and overdentures were excluded from further evaluation. The last search was conducted in February 2008. Key terms included quality of life, patient satisfaction, edentulism, complete denture and overdenture.Results:Among the 90 articles found in the initial search, 27 met the inclusion criteria. This included 18 RCTs and eight prospective and one cohort study. Most of the articles stated superiority of the mandibular implant-retained overdenture therapy over the conventional complete denture regarding patient satisfaction and quality of life.Conclusion:Even with implant treatment presenting higher patient satisfaction and improvement of quality of life, it was not possible to establish a direct comparison between the studies due to differences in adopted methodologies.
Resumo:
Cold-formed steel members are subject to failure caused by buckling, normally under loads smaller than those corresponding to partial or total yielding of the cross section. The buckling of members in bending can be classified as local or global, and the occurrence of one or the other type is expected by the members' geometric characteristics and by the constraints and load conditions. One of the local instability modes that can characterize a member's failure is distortional buckling of the cross section occurring on its own plane and involving lateral displacements and rotations. This paper presents and discusses the procedures and results obtained from experimental tests of cold-formed steel members under bending. Forty-eight beams were carried out on members in simple lipped channel, in pairs, with 6-meter spans and loads applied by concentrated forces at every 1/3 of the span. The thickness, width and dimensions, of the stiffeners were chosen so that the instability by distortion buckling of the cross section was the principal failure mode expected. The experimental results are compared with the obtained results by using the direct strength method.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This work refers a comparison between a government’s index budget and another one which take into account the traditional method, in other words, taking real values practice in market as base. For its achievement will be used the design of a low standard single-family residence, quantifying all the materials needed for its construction with Prices Compositions Table for Budget, provided from the PINI publishing. After that, was made two budgets: one based on the SINAPI index costs, provided from Caixa Econômica Federal and calculated for the Brazilian Institute of Geography and Estatistics; and another based on the costs used in the SESC work in Birigui city, as well as values collected from building material stores in the same city. Finally, with both finalized budgets, will be drawn a direct comparison in order to verifying if the index can be use as parameter for budget calculations for low standard residences
Resumo:
The effects of atropine and methotrimeprazine on epinephrine-induced ventricular arrhythmias were evaluated in halothane-anesthetized dogs. Ten mixed-breed dogs were assigned to 3 treatments (saline, atropine, and methotrimeprazine) in a randomized complete block design. Anesthesia was induced and maintained with halothane (1.5 minimum alveolar concentration) in oxygen. Controlled ventilation was used throughout to maintain eucapnia. Saline, atropine (0.05 mg/kg, IV) or methotrimeprazine (0.5 mg/kg, IV) were administered and, 5 minutes later the arrhythmogenic dose of epinephrine (ADE) was measured by IV infusion of progressively increasing infusion rates of epinephrine, until the ventricular arrhythmia criterion was met (at least 4 ectopic ventricular contractions (EVCs) during a 15-second period). Data were analyzed using a student's t-test for ADE values and multivariate profile analysis for heart rate (HR), arterial blood pressure (ABP), and rate pressure product (RPP). The ADE increased in atropine- and methotrimeprazine-treated groups, whereas 1 and 4 animals from these groups did not develop any ventricular arrhythmia, respectively. Epinephrine induced multiform premature ventricular contractions (PVCs) in the atropine group, whereas ventricular escape beats were observed in the control and methotrimeprazine groups. Heart rate and RPP decreased, and ABP increased at the time of ADE observation in the control group. Epinephrine infusion in the atropine group caused marked increases in HR, ABP, and RPP, which were associated with pulsus alternans in 2 animals. It was concluded that 1) the presence of cholinergic blockade influences the type of ventricular arrhythmia induced by epinephrine; 2) increased ADE values recorded following atropine administration must be cautiously interpreted, since in this situation the PVCs were associated with signs of increased myocardial work and ventricular failure; and 3) the use of a broader arrhythmia criterion (EVCs instead of PVCs) may not allow a direct comparison between ADE values, since it includes ventricular arrhythmias mediated by different mechanisms.
Resumo:
OBJETIVO: Analisar, comparativamente, a obtenção minimamente invasiva com o uso do MINI-HARVEST® e com instrumental tradicional adaptado. MÉTODO: de junho de 1996 a janeiro de 1999, 63 pacientes submetidos à cirurgia de revascularização do miocárdio tiveram suas veias safenas retiradas segundo técnica minimamente invasiva. Nos 30 primeiros pacientes da série utilizou-se método de visão direta com auxílio de dois afastadores de Langenbeck, e nos 33 restantes utilizou-se o MINI-HARVEST®. RESULTADOS: A idade média dos pacientes era de 61 ± 8,75 anos, sendo 52 homens e 11 mulheres. Quarenta e cinco pacientes eram diabéticos, 45 apresentavam sobrepeso/obesidade, 25 eram tabagistas ativos, 32 apresentavam história pregressa de infarto do miocárdio. O tempo médio de retirada da veia safena com afastadores Langenbeck foi de 34,2 ± 8,14 minutos e com o MINI-HARVEST® de 39,20 ± 9,12 minutos. A extensão de veia retirada foi similar nos dois grupos, variando de 10 a 30 cm. Houve uma deiscência superficial no grupo com afastadores de Langenbeck. Houve necessidade de reversão para método tradicional de retirada em dois casos do grupo MINI-HARVEST® e um do grupo Langenbeck. A incidência de infarto transoperatório foi 4,5% (três) no grupo Langenbeck e 3,1%(dois) no grupo MINI-HARVEST®. CONCLUSÕES: Podemos concluir que o método de obtenção de veia safena minimamente invasivo sob visão direta é efetivo e seguro, tanto com o uso de instrumentos tradicionais adaptados para este fim, como com afastadores especialmente constituídos, ressaltando-se que o MINI-HARVEST® dispensa a presença de um auxiliar.
Resumo:
Toxoplasmosis is a worldwide distributed zoonosis that affects man and most warm-blooded animals, with a great economic impact in animal and public health. Serum samples from nine 9-banded armadillos, three 6-banded armadillos, three coatimundis, two opossums and one nutria were submitted for anti-Toxoplasma gondii antibody detection by means of a modified direct agglutination method. Encephalic tissue of three 6-banded armadillos, one 9-banded armadillo, one coatimundi and one nutria were digested in acid pepsin solution and inoculated into Swiss mice for parasite isolation. Only one serum sample from a nine-banded armadillo and two from six-banded armadillos reacted producing titers equal to 256, 512 and 512, respectively. T gondii was isolated in two 6-banded armadillos, one of which was not positive in the serological test. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
What can we learn from solar neutrino observations? Is there any solution to the solar neutrino anomaly which is favored by the present experimental panorama? After SNO results, is it possible to affirm that neutrinos have mass? In order to answer such questions we analyze the current available data from the solar neutrino experiments, including the recent SNO result, in view of many acceptable solutions to the solar neutrino problem based on different conversion mechanisms, for the first time using the same statistical procedure. This allows us to do a direct comparison of the goodness of the fit among different solutions, from which we can discuss and conclude on the current status of each proposed dynamical mechanism. These solutions are based on different assumptions: (a) neutrino mass and mixing, (b) a nonvanishing neutrino magnetic moment, (c) the existence of nonstandard flavor-changing and nonuniversal neutrino interactions, and (d) a tiny violation of the equivalence principle. We investigate the quality of the fit provided by each one of these solutions not only to the total rate measured by all the solar neutrino experiments but also to the recoil electron energy spectrum measured at different zenith angles by the Super-Kamiokande Collaboration. We conclude that several nonstandard neutrino flavor conversion mechanisms provide a very good fit to the experimental data which is comparable with (or even slightly better than) the most famous solution to the solar neutrino anomaly based on the neutrino oscillation induced by mass.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A novel supermolecule constituted by four mu(3)-oxo-triruthenium acetate clusters coordinated to manganese(III)-meso -tetra(4-pyridil)porphyrin acetate ([MnTPyP]CH3COO) has been synthesized. Characterization has been performed by UV-Vis and H-1 NMR spectroscopy. The electrochemical behavior (cyclic voltammetry and spectroelectrochemistry) in N,N'-dimethylformamide has been analyzed in terms of five redox processes: three related to peripheral clusters (Ru-IV,Ru-III,Ru-III/Ru-III,Ru-III,Ru-III/Ru-III,Ru-II,Ru-II) and two centered on the Mn-porphyrin core ((MnP)-P-III/(MnP)-P-II/(MnP2-)-P-II). A direct comparison has been performed between MnTCP and MnTPyP as catalysts for the cyclooctene and cyclohexane oxidation reactions. The improved selectivity exhibited by the supramolecular catalyst for cyclohexane oxidation has been ascribed to electronic effects on the oxomanganese(V) porphyrin species induced by the four peripheral clusters, in the formal (RuRuRuIII)-Ru-IV-Ru-III oxidation state. (C) 2000 Elsevier B.V. S.A. All rights reserved.
Resumo:
The present review describes mainly the history of SnO2-based voltage-dependent resistors, discusses the main characteristics of these polycrystalline semiconductor systems and includes a direct comparison with traditional ZnO-based voltage-dependent resistor systems to establish the differences and similarities, giving details of the basic physical principles involved with the non-ohmic properties in both polycrystalline systems. As an overview, the text also undertakes the main difficulties involved in processing SnO2- and ZnO-based non-ohmic systems, with an evaluation of the contribution of the dopants to the electronic properties and to the final microstructure and consequently to the system's non-ohmic behavior. However, since there are at least two review texts regarding ZnO-based systems [Levinson, L. M., and Philipp, H. R. Ceramic Bulletin 1985;64:639; Clarke, D. R. Journal of American Ceramic Society 1999;82:485], the main focus of the present text is dedicated to the SnO2-based varistor systems, although the basic physical principles described in the text are universally useful in the context of dense polycrystalline devices. However, the readers must be careful of how the microstructure heterogeneity and grain-boundary chemistry are capable to interfere in the global electrical response for particular systems. New perspectives for applications, commercialization and degradation studies involving SnO2-based polycrystalline non-ohmic systems are also outlined, including recent technological developments. Finally, at the end of this review a brief section is particularly dedicated to the presentation and discussions about others emerging non-ohmic polycrystalline ceramic devices (particularly based on perovskite ceramics) which must be deeply studied in the years to come, specially because some of these systems present combined high dielectric and non-ohmic properties. From both scientific and technological point of view these perovskite systems are quite interesting. (c) 2007 Elsevier Ltd. All rights reserved.