82 resultados para digital forensic tool testing

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In the international scientific literature, there are few studies that emphasize the presence or absence of hair in forensic facial reconstructions. There are neither Brazilian studies concerning digital facial reconstructions without hair, nor research comparing recognition tests between digital facial reconstructions with hair and without hair. The miscegenation of Brazilian people is considerable. Brazilian people, and, in particular, Brazilian women, even if considered as Caucasoid, may present the hair in very different ways: curly, wavy or straight, blonde, red, brown or black, long or short, etc. For this reason, it is difficult to find a correct type of hair for facial reconstruction (unless, in real cases, some hair is recovered with the skeletal remains). Aims and methods: This study focuses on the performance of three different digital forensic facial reconstructions, without hair, of a Brazilian female subject (based on one international database and two Brazilian databases for soft facial-tissue thickness) and evaluates the digital forensic facial reconstructions comparing them to photographs of the target individual and nine other subjects, employing the recognition method. A total of 22 assessors participated in the recognition process; all of them were familiar with the 10 individuals who composed the face pool. Results and conclusions: The target subject was correctly recognized by 41% of the 22 examiners in the International Pattern, by 32% in the Brazilian Magnetic Resonance Pattern and by 32% in the Brazilian Fresh Cadavers Pattern. The facial reconstructions without hair were correctly recognized using the three databases of facial soft-tissue thickness. The observed results were higher than the results obtained using facial reconstructions with hair, from the same skull, which can indicate that it is better to not use hair, at least when there is no information concerning its characteristics. © 2013 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A calorimetria Exploratória Diferencial (DSC) foi utilizada para estudar o comportamento térmico de amostras de cabelo e verificar a possibilidade de identificar um indivíduo com base nas curvas DSC de um banco de dados. Amostras de cabelo de estudantes e funcionários do Instituto de Química de Araraquara UNESP, foram obtidas para construir um banco de dados. Procurou-se assim identificar de um indivíduo sob incógnita, utilizando-se a curva DSC deste banco de dados.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetivou-se, com o trabalho, avaliar dois métodos de estimativa da área foliar, em plantas de laranja Pêra, pela análise da imagem digital obtida com scanner e câmera fotográfica digital. Para determinar a área das folhas, um grupo de discos foi colocado sobre um leitor de scanner, sendo que a imagem obtida foi armazenada. Os mesmos grupos de discos foram fixados sobre cartolina branca e fotografados com câmera fotográfica digital. As imagens obtidas da câmera fotográfica e do scanner foram processadas utilizando ferramentas de um editor de imagem que permite a contagem de pixels de determinada cor, no caso verde. Para a comparação dos métodos, os discos foram submetidos a integrador óptico de área foliar modelo LICOR-3100, utilizando os mesmos agrupamentos. Foram coletadas 20 folhas (cinco em cada quadrante da planta) por parcela de um experimento para comparação de fertilizantes comerciais e doses de zinco, aplicados via foliar, em plantas de sete anos de idade. O experimento foi composto de sete tratamentos e quatro repetições, num total de 28 parcelas. Os dois métodos apresentaram alta correlação com a área estimada pelo integrador óptico de área, considerado como método de referência. O método da análise da imagem obtida com câmera fotográfica, na resolução de 5.0 megapixel, foi mais precisa quando comparada à área estimada pelo integrador óptico de área.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work is an example of the improvement on quantitative fractography by means of digital image processing and light microscopy. Two techniques are presented to investigate the quantitative fracture behavior of Ti-4Al-4V heat-treated alloy specimens, under Charpy impact testing. The first technique is the Minkowski method for fractal dimension measurement from surface profiles, revealing the multifractal character of Ti-4Al-4V fracture. It was not observed a clear positive correlation of fractal values against Charpy energies for Ti-4Al-4V alloy specimens, due to their ductility, microstructural heterogeneities and the dynamic loading characteristics at region near the V-notch. The second technique provides an entire elevation map of fracture surface by extracting in-focus regions for each picture from a stack of images acquired at successive focus positions, then computing the surface roughness. Extended-focus reconstruction has been used to explain the behavior along fracture surface. Since these techniques are based on light microscopy, their inherent low cost is very interesting for failure investigations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB (R)/SINIULINK (R) models to structural VHDL-AMS descriptions. The tool developed, named (MSSV)-S-2, reads a SIMULINK (R) model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the SystemVision (TM). To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB (R)/SIMULINK (R). The VHDL-AMS code generated automatically by (MSSV)-S-2, (MATLAB (R)/SIMULINK (R) to SystemVision (TM)), was then simulated in the SystemVision (TM). The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study.Materials and Methods: Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI).Results: The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99).Conclusion: Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Root resorption can cause damage in orthodontic patients. Digital subtraction radiography (DSR) is a useful resource for the detection of mineral losses. The purpose of this study was to compare the efficacy of digital radiography (DR) and DSR in detecting simulated external root resorption. Examiner agreement between the 2 techniques was also evaluated. Methods: Root resorptions of various sizes were simulated on the apical and lingual aspects of 49 teeth from 9 dry human mandibles. The teeth were radiographed in standardized conditions. The radiographs were registered with Regeemy Image Registration and Mosaicking (version 0.2.43-RCB, DPI-INPE, Sao Jose dos Campos, São Paulo, Brazil) and subtracted with Image Tool (University of Texas Health Science Center at San Antonio). The subtracted images and the digital radiographs were evaluated by 3 oral radiologists. Results: No statistically significant differences were found for the methods in the detection of apical root resorptions, independently from lesion size, and of lingual resorptions of 1.2 mm or greater. DSR was significantly better than DR for detection of lingual resorptions up to 1 mm. Resorptions less than 0.5 mm were not precisely detected by either method. DSR provided better intraexaminer and interexaminer agreement than did DR. Conclusions: Both methods are precise for detection of apical root resorptions as small as 0.5 mm and lingual resorptions of 1 mm or more. However, DSR frequently performed better than did DR. (Am J Orthod Dentofacial Orthop 2011;139:324-33)