18 resultados para detrusor underactivity

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the histopathological and immunohistochemical alterations induced by detrusor instability in the bladder of rabbits submitted to partial bladder outlet obstruction. Thirty male Norfolk rabbits were divided into 2 groups, a clinical control and a group with detrusor instability. Urine culture, cystometric study, histopathological and immunohistochemical analysis were performed in all animals prior to surgery (M1) and 4 weeks after-surgery (M2). Partial obstruction (G2) resulted in a 2.5 fold increment (p < 0.05) in bladder weight when compared to control (G1). Four weeks after surgery, 93% of animals in G2 developed cystitis. Partial obstruction resulted in detrusor instability at M2 and bladder capacity was significantly increased (p < 0.05) from M1 to M2. The incidence of mild to moderate mucosal and adventitious fibrosis at M2 was higher in G2 (p < 0.05) when compared to G1. Inflammatory reaction at M2 was statistically higher (p < 0.05) in G2. There was no difference in muscular hypertrophy between M1 and M2 in G1. However, 67% of G2 bladders showed a moderate to intense muscular hypertrophy at M2. Hyperplasia of the epithelium was also increased in G2 when M1 and M2 were compared (p < 0.05). Detrusor instability induced by partial bladder outlet obstruction caused significant histopathological and immunohistochemical alterations in the bladder of rabbits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A incontinência urinária adquirida é uma condição debilitante e, muitas vezes, incurável que acomete fêmeas castradas e raramente fêmeas inteiras ou machos. A manifestação clínica pode ocorrer em qualquer momento após a gonadectomia e resulta em graves problemas no manejo do paciente. Os mecanismos que desencadeiam a incontinência após ovariectomia envolvem decréscimo na pressão de fechamento uretral, alterações hormonais, aumento na deposição de colágeno na musculatura lisa da bexiga, diminuição na contratilidade do músculo detrusor e redução na resposta aos estímulos elétricos e ao carbachol. O diagnóstico é realizado pelo histórico do animal, pelo exame físico, pelos exames laboratoriais, pelo perfil de pressão uretral, pela ultrassonografia e pelas radiografias abdominais. O tratamento clínico envolve utilização de fármacos -adrenérgicos, estrógenos, análogos de GnRH e agentes antidepressivos. As técnicas cirúrgicas recomendadas correspondem à uretropexia, cistouretropexia, aplicação de colágeno na uretra e colpossuspensão. Melhor compreensão da etiologia, da fisiopatologia, dos métodos de diagnóstico e tratamentos é fundamental em razão do pouco conhecimento e da identificação dessa condição no Brasil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of intravaginal electrical stimulation (IES) on pelvic floor muscle (PFM) strength in patients with mixed urinary incontinence (MUI). Between January 2001 and February 2002, 40 MUI women (mean age: 48 years) were studied. Urge incontinence was the predominant symptom; 92.5% also presented mild stress urinary incontinence (SUI). Selection criteria were clinical history and urodynamics. Pre-treatment urodynamic study showed no statistical differences between the groups. Ten percent of the women in each group had involuntary detrusor contractions. Patients were randomly distributed, in a double-blind study, into two groups. Group G 1 (n=20), effective IES, and group G2 (n=20), sham IES, with follow-up at 1 month. The following parameters were studied: (1) clinical questionnaire, (2) examiner's evaluation of perineal muscle strength, (3) objective evaluation of perineal muscle by perineometry, (4) vaginal weight test, and (5) urodynamic study. The IES protocol consisted of three 20-min sessions per week over a 7-week period using a Dualpex Uro 996 at 4 Hz. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence, present in all patients before treatment, was reduced to 15% in G1 and 31.5% in G2 post-treatment. The subjective evaluation of PFM strength demonstrated a significant improvement in G1. Objective evaluation of PFM force by perineometer showed a significant improvement in maximum peak contraction post-treatment in both groups. In the vaginal weight test, there was a significant increase in average number of cone retentions post-treatment in both groups. With regard to satisfaction level, after treatment, 80% of the patients in G1 and 65% of the patients in G2 were satisfied. There was no statistically significant difference between the groups. There was a significant improvement in PFM strength from both effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy in treating MUI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background the aim of this study was to compare effective and sham intravaginal electrical stimulation (IES) in treating mixed urinary incontinence. Methods. Between January 2001 and February 2002, 40 women were randomly distributed, in a double-blind study, into two groups: group G1 (n = 20), effective IES, and group G2 (n = 20), sham IES, with follow up at one month. Different parameters was studied: 1. clinical questionnaire, 2. body mass index; 3. 60-min pad test; 4. urodynamic study. The protocol of IES consisted of three 20-min sessions per week over a seven-week period. The Dualpex Uro 996 used a frequency of 4 Hz. Results. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence was reduced to 15% in G1 and 31.5% in G2; there was no significant difference between the groups. In the analog wetness and discomfort sensation evaluations were reduced significantly in both groups. The pretreatment urodynamic study showed no statistical difference in urodynamic parameters between the groups. Ten percent of the women presented involuntary detrusor contractions. In the 60-min pad test, there was a significant reduction in both groups. In regards to satisfaction level, after treatment, 80% of G1 patients and 65% of G2 patients were satisfied. There was no statistically significant difference between the groups. Conclusion. Significant improvement was provided by effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVETo evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO).METHODSWe evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW.Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded.After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction.RESULTSThe UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g.We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups.CONCLUSIONDespite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Propose a new experimental model of bladder instability in rabbits after partial bladder obstruction. MATERIALS and METHODS: Thirty North Folk male rabbits, weighting 1,700 to 2,820 g (mean: 2,162 g) were studied. The animals were distributed in 2 experimental groups, formed by 15 rabbits each: Group 1 - clinical control. In this group there was no surgical intervention; Group 2 - bladder outlet obstruction. In this group, after anesthetizing the animal, urethral cannulation with Foley catheter 10F was performed and then an adjustable plastic bracelet was passed around the bladder neck. It was then adjusted in order to not constrict the urethra. The following parameters were studied in M1 - pre-operative period; M2 - 4 weeks post-operatively moments: 1)- urine culture; 2)- cystometric study; 3)- serum creatinine and BUN. RESULTS: Bladder weight was 2.5 times larger in the group with obstruction than in the control group. Cystometric evaluation showed a significant increase in maximal vesical volume in the final moment at Group G2. However, there was no statistically significant difference among the groups studied. There was no statistically significant difference between maximal detrusor pressure and vesical compliance in the different moments or in the studied groups. There was an absence of uninhibited detrusor contractions in all the animals in group 1, and involuntary contractions were detected in 93% of group 2 animals. There was no significant variation in BUN and serum creatinine either among the groups or in the same group. CONCLUSIONS: We observed in the group with obstruction a bladder weight 2.5 higher than normal bladders. We detected involuntary contractions in 93% of the animals in group 2, establishing this experimental model as appropriate to secondary bladder instability and partial bladder outlet obstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar a concordância dos diferentes parâmetros urodinâmicos comparados à cistometria simplificada, permitindo uma diminuição na relação custo-benefício no diagnóstico da incontinência urinária de esforço (IUE) na mulher. MÉTODOS: foram coletadas e avaliadas retrospectivamente as informações contidas dos prontuários de trinta pacientes acompanhadas, no período de janeiro de 2000 a março de 2001. Todas foram submetidas a exame físico geral e ginecológico. O estudo urodinâmico foi realizado pela técnica convencional, utilizando-se aparelho Dynograph Recorder R-611. A cistometria simplificada foi realizada com auxílio de um equipo em Y de PVC (pressão venosa central), conectado a um sonda de Foley 14 F, que permitia tanto a infusão de soro fisiológico como a captação da pressão intra-vesical. Foram analisados os parâmetros: volume residual, capacidade vesical, complacência, presença de contrações involuntárias do detrusor e perdas urinárias aos esforços. Para determinação da proporção de concordância entre os métodos foram utilizados o teste de concordância de Pearson e o teste de Wilcoxon, para amostras relacionadas. RESULTADOS: a média de idade foi de 50 anos, com extremos variando de 28 a 70 anos. O índice de concordância entre os estudos, na demonstração das perdas urinárias aos esforços, foi de 67%. Para a detecção das contrações involuntárias do detrusor, a proporção de concordância foi de 90%. A média do volume residual encontrado na cistometria simplificada foi de 16,8 ml contra 2 ml da urodinâmica convencional, com diferença significativa (p < 0,01). A média de capacidade vesical máxima no estudo urodinâmico foi de 440,5 ml, enquanto que, na cistometria simplificada, foi de 387 ml (p < 0,05). A complacência vesical foi, em média, significativamente maior na cistometria simplificada (43,0 ml/cmH2O) quando comparada ao estudo urodinâmico (31,5 ml/cmH2O), com p < 0,01. CONCLUSÃO: Avaliações preliminares sugerem que a propedêutica uroginecológica associada à cistometria simplificada é uma opção a ser considerada na avaliação clínica e pré-operatória de pacientes com IUE em substituição à urodinâmica convencional, particularmente onde esta última não se encontra disponível. A cistometria simplificada é um exame acessível que é capaz de detectar contrações involuntárias do detrusor, assim como identificar perdas urinárias com relativa sensibilidade, proporcionando ao examinador noções fidedignas do comportamento vesical.