24 resultados para delivery time

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

An accurate estimate of machining time is very important for predicting delivery time, manufacturing costs, and also to help production process planning. Most commercial CAM software systems estimate the machining time in milling operations simply by dividing the entire tool path length by the programmed feed rate. This time estimate differs drastically from the real process time because the feed rate is not always constant due to machine and computer numerical controlled (CNC) limitations. This study presents a practical mechanistic method for milling time estimation when machining free-form geometries. The method considers a variable called machine response time (MRT) which characterizes the real CNC machine's capacity to move in high feed rates in free-form geometries. MRT is a global performance feature which can be obtained for any type of CNC machine configuration by carrying out a simple test. For validating the methodology, a workpiece was used to generate NC programs for five different types of CNC machines. A practical industrial case study was also carried out to validate the method. The results indicated that MRT, and consequently, the real machining time, depends on the CNC machine's potential: furthermore, the greater MRT, the larger the difference between predicted milling time and real milling time. The proposed method achieved an error range from 0.3% to 12% of the real machining time, whereas the CAM estimation achieved from 211% to 1244% error. The MRT-based process is also suggested as an instrument for helping in machine tool benchmarking.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivo: estudar as influências da diferença de pesos entre gêmeos, no nascimento, sobre o resultado perinatal. Métodos: analisaram-se, retrospectivamente, as informações referentes aos partos gemelares ocorridos na Maternidade do Hospital Regional de Clínicas de Sorocaba, SP, de julho de 1997 a junho de 1998. A amostragem foi composta de 89 mães e seus gêmeos, divididos em três classes de diferença de pesos ao nascer: com concordância (diferença <15%), discordância leve (de 15 a 25%) e discordância grave (>25%). As variáveis independentes analisadas foram essas três classes e as dependentes foram: baixo peso ao nascer, índice de Apgar menor que 7 no primeiro e quinto minuto, nascimentos pré-termo, tempo médio de internação do recém-nascido no berçário e coeficiente de mortalidade perinatal I. Para análise estatística utilizaram-se o teste de Kruskal-Wallis, complementado pelo teste de Hollander, e o teste de Blackwell. Resultados: a incidência de discordância de pesos entre pares de gêmeos foi de 30,3%, sendo 19,1% de discordância leve e 11,2% de discordância grave. Observamos nas classes, respectivamente, os números de gestações (62, 17 e 10) e de nascimentos pré-termo (32, 9 e 7). Para o primeiro e o segundo gêmeo, observamos: baixo peso ao nascer (39/41, 13/12 e 8/9), Apgar <7 no primeiro minuto (16/13, 3/7 e 2/3), Apgar menor que 7 no quinto minuto (4/4, 0/2 e 1/2), tempo médio (dias) de internação no berçário (3,7/3,7, 4,6/6,0 e 7,3/8,7) e coeficiente de mortalidade perinatal I (22,4/16,8, 0/16,8 e 5,6/5,6). Conclusões: o baixo peso ao nascer e nascimentos pré-termo foram mais freqüentes nos gêmeos da classe com discordância grave. Houve tendência ao agravamento progressivo do resultado perinatal, respectivamente, nas classes com concordância, discordância leve e discordância grave.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the advent of a global economy, Lean Six Sigma meets the demand of new production process that creates products within the customer’s specification without any wastage. The objectives of this work is to use the concepts Lean Manufacturing and Six Sigma parallel to minimize costs, increase the customer base, reduce the delivery time which implies an increase in the turnover of products on the shelves in a packaging company. We used the DMAIC method to continue working. The method DMAIC indicated the main failure modes that were fixed in the step improve. At this stage the tools of Lean Manufacturing gain tremendous value by optimizing processes with defects. The conclusion involves an increase in monthly billing, a corporate restructuring and, finally, a renewal in how to conduct the work of management

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The competition among companies nowadays, caused by globalization and with customers more and more demanding, makes the companies rethink their strategies for survival. To improve their competition the companies are adopting management tool to improve the manufacturing management, which is considered a key to success. The present study aimed to develop a method, based on techniques of theory of constraints and operational research, to ensure the best use of resources and best decision of a production line on a steel company, with focus in the customers’ delivery time, which is a requirement of the current market. The conclusion of this study is that the correct use of the management tools, such as theory of constraints and operational research, can ensure a long survival for the companies that duel for the market share, especially in regard to customers’ delivery time, that generates their satisfaction

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The gas turbine (GT) is known to have: low cost of capital over the amount of energy, high flexibility, high reliability, short delivery time, commissioning and commercial operation at the beginning and quick departure. The gas turbine is also recognized for its superior environmental performance, manifested in air pollution containment and reducing greenhouse gases (Mahi, 1994). Gas turbines in simple cycle mode (SC) have long been used by utilities to limited power generation peak. In addition, manufacturing facilities use gas turbines for power generation units on site, often in combination with the process of heat production, such as hot water and steam process. In recent years, the performance of industrial gas turbines has been improved due to significant investments in research and development, in terms of fuel to electricity conversion efficiency, plant capacity, availability and reliability. The greater availability of energy resources such as natural gas (NG), the significant reduction of capital costs and the introduction of advanced cycles, have also been a success factor for the increased use of gas turbines to load applications base (Poulikas, 2004). Open Cycle Gas Turbine with a greater degree of heat to the atmosphere may alternatively be used to produce additional electricity using a steam cycle, or to compose a cogeneration process. The combined cycle (CC) uses the heat from the gas turbine exhaust gas to increase the power output and increase the overall efficiency of more than 50% second (Najjar, 2001). The initial discovery of these cycles in the commercial power generation market was possible due to the development of the gas turbine. Only from the 1970s that gas turbine inlet temperature and therefore the exhaust gas temperature was sufficiently high to allow a better efficiency in the combined cycle ... (Complete Abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drug delivery systems are essential components of drugs controlled release. In the last decades, several drug delivery technologies have emerged including capsules, liposomes. microparticles, nanoparticles, and polymers. These components must be biocompatible, biodegradable, and display a desired biodistribution providing a long-term availability of the therapeutic at specific target over time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To achieve effective drug concentration at the intended site for a sufficient period of time is a requisite desired for many drug formulations. For drugs intended to ocular delivery, its poor bioavailability is due to pre-corneal factors. Most ocular diseases are treated by topical drug application in the form of solution, suspension and ointment. However, such dosage forms are no longer sufficient to combat some ocular diseases. Intravitreal drug injection is the current therapy for disorders in posterior segment. The procedure is associated with a high risk of complications, particularly when frequent, repeated injections are required. Thus, sustained-release technologies are being proposed, and the benefits of using colloidal carriers in intravitreal injections are currently under investigation for posterior drug delivery. This review will discuss recent progress and specific development issues relating to colloidal drug delivery systems, such as liposomes, niosomes, nanoparticles, and microemulsions in ocular drug delivery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High amylose cross-linked to different degrees with sodium trimetaphosphate by varying base strength (2% or 4%) and contact time (0.5-4 h) was evaluated as non-compacted systems for sodium diclophenac controlled release. The physical properties and the performance of these products for sodium diclophenac controlled release from non-compacted systems were related to the structures generated at each cross-linking degree. For samples at 2% until 2 h the swelling ability, G' and eta* values increased with the cross-linking degree, because the longer polymer chains became progressively more entangled and linked. This increases water uptake and holding, favoring the swelling and resulting in systems with higher viscosities. Additionally, the increase of cross-linking degree should contribute for a more elastic structure. The shorter chains with more inter-linkages formed at higher cross-linking degrees (2%4h and 4%) make water caption and holding difficult, decreasing the swelling, viscosity and elasticity. For 2% samples, the longer drug release time exhibited for 2%4h sample indicates that the increase of swelling and viscosity contribute for a more sustained drug release, but the mesh size of the polymeric network seems to be determinant for the attachment of drug molecules. For the 4% samples, smaller meshes size should determine less sustained release of drug. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drug delivery systems based on natural polysaccharides, such as chitosan (CS) and pectin (PC), rather than on synthetic polymers, have been widely studied. Some reasons for that are low toxicity and costs and high biodegradability of the formers. A multiparticulate system based on CS and PC was developed in our laboratories, including the addition of an enteric polymer, cellulose acetate phtalate (CAP). Such improvement promoted stronger gastric and enteric resistances, as assessed in vitro, making the systems more selective to enzymatic degradation in the colon. Although in vitro dissolution tests can simulate some properties concerning the gastrointestinal transit (GT), collaborating to characterize the systems behavior in the biological fluids, frequently they do not result in satisfactory in vitro/in vivo correlations. The objective of this work was to follow in vivo the GT of the particles developed by means of AC biosusceptometry (ACB), a non-invasive and of low cost methodology. The particles containing ferrite in powder form were prepared by complex coacervation using an ideal 3:1:1 mass ratio for PC:CS:CAP. The magnetic particles were administered to healthy volunteers by oral route. The GT was monitored by using multi-sensor ACB system and the signal acquisition was performed every IS min until the colonic region was reached. By means of ACB technique, it was possible to acquiring images generated by the magnetic particles within the whole gastrointestinal tract including the colonic region. Variable particles transit times were observed among the volunteers, but without interference on the mapping of the particles until the colonic region. The particles were able to produce magnetic field strong enough to generate signals adequate for mapping the particles. The results suggest that integral particles reached the colon, after they resisted against gastric and enteric media. Studies associating transit time and in vivo drug release are in development in order to confirm the efficiency of the systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We compared the pharmacokinetics of intraosseous (IO) drug delivery via tibia or sternum, with central venous (CV) drug delivery during cardiopulmonary resuscitation (CPR).Methods: CPR of anesthetized KCl arrest swine was initiated 8 min post arrest. Evans blue and indocyanine green, each were simultaneously injected as a bolus with adrenaline through IO sternal and tibial needles, respectively, n = 7. In second group (n = 6) simultaneous IO sternal and IV central venous (CV) injections were made.Results: Peak arterial blood concentrations were achieved faster for sternal IO vs. tibial IO administration (53 +/- 11 s vs. 107 +/- 27 s, p = 0.03). Tibial IO dose delivered was 65% of sternal administration (p = 0.003). Time to peak blood concentration was similar for sternal IO and CV administration (97 +/- 17 s vs. 70 +/- 12 s, respectively; p = 0.17) with total dose delivered of sternal being 86% of the dose delivered via CV (p = 0.22).Conclusions: IO drug administrations via either the sternum or tibia were effective during CPR in anesthetized swine. However, IO drug administration via the sternum was significantly faster and delivered a larger dose. (C) 2011 Elsevier B.V. All rights reserved.