26 resultados para data accuracy
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The objective of this study was to evaluate and compare 3 impression techniques for osseointegrated implant transfer procedures.Materials and Methods: (1) Group Splinted with Acrylic Resin (SAR), impression with square copings splinted with prefabricated autopolymerizing acrylic resin bar; (2) Group Splinted with Light-Curing Resin (SLR), impression, with square copings splinted with prefabricated light-curing composite resin bar; (3). Group Independent Air-abraded (IAA), impression with independent square coping aluminum oxide air-abraded. Impression procedures were performed with polyether material, and the data obtained was compared with a control group. These were characterized by metal matrix (MM) measurement values of the implants inclination positions at 90 and 05 degrees in relation to the matrix surface. Readings of analogs and implant inclinations were assessed randomly through graphic computation AutoCAD software. Experimental groups angular deviation with MM were submitted to analysis of variance and means were compared through Tukey's test (P < 0.05).Results: There was no statistical significant difference between SAR and SLR experimental groups and MM for vertical and angulated implants. Group IAA presented a statistically significant difference for angulated implants.Conclusion: It was concluded within the limitations of this study, that SAR and SLR produced more accurate casts than IAA technique, which presented inferior results.
Resumo:
O objetivo deste trabalho e apresentar uma investigação preliminar da precisão nos resultados do sistema de localização geográfica de transmissores desenvolvido utilizando o software da rede brasileira de coleta de dados. Um conjunto de medidas de desvio Doppler de uma única passagem do satélite, considerando uma Plataforma de Coleta de Dados (PCD) e uma rede de estações de recepção terrestrês, e denominado uma rede de recepção de dados. Assim, a rede brasileira de coleta de dados com o uso de múltiplas estações de recepção permitira o incremento na quantidade de dados coletados com consequente melhora na precisão e na confiabilidade das localizações fornecidas. Consequentemente uma maior quantidade de localizações válidas e mais precisas. Os resultados e análises foram obtidos sob duas condições: na primeira foi considerada uma condição prática com dados reais e dados ideais simulados, para comparar os resultados considerando a mesma passagem do satélite, transmissor e duas estações de recepção conhecidas; na segunda foram consideradas as condições ideais simuladas a partir de medidas de um transmissor fixo, três estações de recepção e dois satélites. Os resultados utilizando a rede de recepção de dados foram bastante satisfatórios. O estudo realizado mostrou a importãncia da instalação de novas estações de recepção terrenas distribuídas no territorio nacional, para um aumento na quantidade de medidas e consequentemente uma maior quantidade de localizações válidas e mais precisas.
Resumo:
Geometric accuracy of a close-range photogrammetric system is assessed in this paper considering surface reconstruction with structured light as its main purpose. The system is based on an off-the-shelf digital camera and a pattern projector. The mathematical model for reconstruction is based on the parametric equation of the projected straight line combined with collinearity equations. A sequential approach for system calibration was developed and is presented. Results obtained from real data are also presented and discussed. Experiments with real data using a prototype have indicated 0.5mm of accuracy in height determination and 0.2mm in the XY plane considering an application where the object was 1630mm distant from the camera.
Resumo:
The purpose of this study was to determine the accuracy of mechanical torque devices in delivering target torque values in dental offices in Salvador, Brazil. A team of researchers visited 16 dental offices, and the clinicians applied torque values (20 and 32 Ncm) to electronic torque controllers. Five repetitions were completed at each torque value and data were collected. When 20 Ncm of torque was used, 62.5% of measured values were accurate (within 10% of the target value). For 32 Ncm, however, only 37.5% of these values were achieved. Several of the tested mechanical torque devices were inaccurate. Int J Prosthodont 2011;24:38-39.
Resumo:
Starting from the well established form of the Dirac action coupled to the electromagnetic and torsion field we find that there is some additional softly broken local symmetry associated with torsion. This symmetry fixes the form of divergences of the effective action after the spinor fields are integrated out. Then the requirement of renormalizability fixes the torsion field to be equivalent to some massive pseudovector and its action is fixed with accuracy to the values of coupling constant of torsion-spinor interaction, mass of the torsion and higher derivative terms. Implementing this action into the abelian sector of the Standard Model we establish the upper bounds on the torsion mass and coupling. In our study we used results of present experimental limits on four-fermion contact interaction (LEP, HERA, SLAC, SLD, CCFR) and TEVATRON limits on the cross section of new gauge boson, which could be produced as a resonance at high energy pp̄ collisions. © 1998 Elsevier Science B.V. All rights reserved.
Resumo:
Until mid 2006, SCIAMACHY data processors for the operational retrieval of nitrogen dioxide (NO2) column data were based on the historical version 2 of the GOME Data Processor (GDP). On top of known problems inherent to GDP 2, ground-based validations of SCIAMACHY NO2 data revealed issues specific to SCIAMACHY, like a large cloud-dependent offset occurring at Northern latitudes. In 2006, the GDOAS prototype algorithm of the improved GDP version 4 was transferred to the off-line SCIAMACHY Ground Processor (SGP) version 3.0. In parallel, the calibration of SCIAMACHY radiometric data was upgraded. Before operational switch-on of SGP 3.0 and public release of upgraded SCIAMACHY NO2 data, we have investigated the accuracy of the algorithm transfer: (a) by checking the consistency of SGP 3.0 with prototype algorithms; and (b) by comparing SGP 3.0 NO2 data with ground-based observations reported by the WMO/GAW NDACC network of UV-visible DOAS/SAOZ spectrometers. This delta-validation study concludes that SGP 3.0 is a significant improvement with respect to the previous processor IPF 5.04. For three particular SCIAMACHY states, the study reveals unexplained features in the slant columns and air mass factors, although the quantitative impact on SGP 3.0 vertical columns is not significant.
Resumo:
The contents of some nutrients in 35 Brazilian green and roasted coffee samples were determined by flame atomic absorption spectrometry (Ca, Mg, Fe, Cu, Mn, and Zn), flame atomic emission photometry (Na and K) and Kjeldahl (N) after preparing the samples by wet digestion procedures using i) a digester heating block and ii) a conventional microwave oven system with pressure and temperature control. The accuracy of the procedures was checked using three standard reference materials (National Institute of Standards and Technology, SRM 1573a Tomato Leaves, SRM 1547 Peach Leaves, SRM 1570a Trace Elements in Spinach). Analysis of data after application of t-test showed that results obtained by microwave-assisted digestion were more accurate than those obtained by block digester at 95% confidence level. Additionally to better accuracy, other favorable characteristics found were lower analytical blanks, lower reagent consumption, and shorter digestion time. Exploratory analysis of results using Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) showed that Na, K, Ca, Cu, Mg, and Fe were the principal elements to discriminate between green and roasted coffee samples. ©2007 Sociedade Brasileira de Química.
Resumo:
The aim of this study was to evaluate the dimensional changes of denture bases made from different resins after different storage periods. For this purpose, 25 sets of plaster models/resin bases were prepared using 4 acrylic resins submitted to two types of polymerization: 1- QC-20 submitted to polymerization by microwave energy; 2- QC-20 submitted to polymerization by water hot bath; 3- Vipi Cril submitted to polymerization by water hot bath; 4- Vipi Wave submitted to polymerization by microwave energy; and 5- Onda Cryl submitted to polymerization by microwave energy. After polymerization, the specimens were sectioned for accuracy readings using a comparison microscope. Readings were taken at 3 points: the crests of the right (A) and left (B) ridges, and the median region of the palate, in 4 different periods. The data obtained were submitted to two-way ANOVA and Tukey's test at 5% significance level. The greatest distortions were found in the posterior palatal region of the base (M), with statistically significant difference (p<0.05) for the studied resins. All acrylic resins presented dimensional changes and the storage period influenced these alterations.
Resumo:
The aim of this study was to evaluate whether digitized images obtained from occlusal radiographs taken with low or over dose of radiation could be improved with the aid of computer software for digital treatment. Thirteen occlusal radiographs of a dry skull were taken employing 13 different exposure times. The radiographs were digitized and then manipulated with the program for image editing. 143 evaluations were performed by specialists in dental radiology who classified radiographs as appropriate or not appropriate for interpretation. Test Z was used for statistical analysis of the data and the results showed that it is possible to manipulate digitized radiographic images taken with 75% of the ideal exposure time and to make them suitable for interpretation and diagnosis. Conversely, it was concluded that the over exposed images, 57.50% above the standard exposure time, were inadequate.
Resumo:
In this work, a new approach for supervised pattern recognition is presented which improves the learning algorithm of the Optimum-Path Forest classifier (OPF), centered on detection and elimination of outliers in the training set. Identification of outliers is based on a penalty computed for each sample in the training set from the corresponding number of imputable false positive and false negative classification of samples. This approach enhances the accuracy of OPF while still gaining in classification time, at the expense of a slight increase in training time. © 2010 Springer-Verlag.