120 resultados para cycled lighting
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The objective was to investigate whether the productivity of rabbit does can be improved, when natural photoperiod is decreasing, by adopting a supplemental lighting program. Three experiments were conducted involving two groups: control, submitted to the natural decreasing photoperiod, and supplemented with a lighting program which provided 14 h light/24 h beginning at 10 weeks of age. In the first experiment, 20 nulliparous does, 10 from each group, were euthanized 8 h after being presented to a buck; the overall number of follicles, whose diameter exceeded I mm, was determined macroscopically. The right ovaries were collected, histologically analyzed, and electronically measured. In the second experiment, 30 nulliparous does, 15 from each group, were presented to a buck (day 1). Receptive does were euthanized on day 8 to evaluate embryonic survival (number of normal embryos/ovulation rate). In the third experiment, 48 nulliparous does, 24 from each group, were followed from the first presentation to the buck until the weaning of the first litter. The effect of treatment on reproductive and body weight traits of does, and litter performance traits, at birth and weaning, was evaluated. The average number of follicles whose diameter exceeded 1 mm was higher in the treatment group (12.05 +/- 1.07 vs. 8.63 +/- 1.00, P=0.03 7). Receptive does of the treatment group had heavier ovaries relative to those of the control group (790 +/- 59 vs. 470 +/- 64 mg, P=0.004), whereas no treatment difference regarding this trait was found for non-receptive ones. Treatment had a favorable effect on pregnancy rate of total exposed and of receptive does (80.0% vs. 33.3%, P=0.01, and 92.3% vs. 50.0%, P=0.02, respectively). The number of underdeveloped embryos was lower (0.067 +/- 0.380 vs. 2.500 +/- 0.455, P=0.004), embryonic survival up to day 8, and uterus weight was higher in the treatment group (0.839 +/- 0.075 vs. 0.534 +/- 0.087, P=0.033 and 13.83 +/- 0.72 vs. 10.99 +/- 0.84, P=0.037, respectively). Number of presentations tended to be lower (1.32 +/- 0.17 vs. 1.75 +/- 0.16, P=0.077) and adjusted litter size in the first reproductive cycle tended to be higher (7.09 +/- 0.89 vs. 5.22 +/- 0.68, P=0.091) in the treatment group relative to the control.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work deals with a red phosphor. Y3BO6:Eu3+, and its corresponding poly(N-vinylpyrrolidone) (PVP)/Y3BO6:Eu3+ luminescent composite film suitable for applications in the next generation of Hg-free lamps based on near ultraviolet (UV) light emitting diodes (LEDs). Well crystallized samples of Y3BO6 powders with the Eu3+ content up to 20 mol% were prepared by the Pechini method. After structural, morphological and optical characterization, the best doping rate of Eu3+ in the matrix was determined to be 15 mol%. This optimal powder, which is highly friable, was easily ground into fine particles and homogeneously dispersed into a PVP polymer solution to give rise to a polymer phosphor composite. Structural and optical features of the composite film have been studied and compared to those of a pristine PVP film and Y3BO6:Eu3+ powder. All the characterization (XRD, SAXS, luminescence...) proved that the red phosphor particles are well incorporated into the polymer composite film which exhibited the characteristic red emission of Eu3+ under UV light excitation. Furthermore, photostability of the polymer/phosphor composite film under UV-LED irradiation was evaluated from exposure to accelerated artificial photoageing at wavelengths above 300 nm.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In 2010, an accident occurred in Americana-SP, Brazil, involving two trains and one bus on a Grade Crossing, when 10 people died and 17 were injured including workers. This paper aims to analyze the accident using the Model of Analysis and Prevention of Work Accidents (MAPA). The method provides observation of work, interviews and analysis of documents to understand precedents of the event in the following stages: to understand the usual work from the involved people, the changes occurred in the system, the operation of barriers, managerial and organizational aspects. By the end, measures are suggested to avoid new occurrences. The accident took place at night in a site with insufficient lighting. The working conditions of bus drivers, train operators and watchmen are inadequate. There were only symbolic barriers (visual and acoustic signals) triggered manually by watchman upon train operator radio communication. The fragility of the barrier system associated to poor lighting and short time to trigger the signaling seem to play a critical role in the event. Contrary to the official report which resulted in guilt of the bus driver, the conclusion of the paper emphasizes the fragility of the safety system and the need of level crossing reproject.
Resumo:
Three experiments were carried out to analyze the performance and egg quality of Japanese quails throughout the day when submitted to different lighting programs. In each experiment, birds were submitted to a period of 28 days for adaptation to the lighting program. During the following three days, each day - from 7 am to 7 pm or 9 pm - was divided into six or seven periods of two hours each, and the remaining hours corresponded to another single period. All birds were submitted to the same management practices, and received water and feed ad libitum. The experimental diet was formulated according to NRC (1994) standards. It was observed lower feed intake in the period of 9 pm to 7 am, and a higher incidence of lay from 3 pm to 7 pm, as opposite to hens, which peak of egg laying occurs during the morning. Some controversial results were found among experiments as to eggshell quality during the different periods of the day. Variation on the lighting program had little influence on the other performance and egg quality parameters.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Statement of problem. When clinical fractures of the ceramic veneer on metal-ceramic prostheses can be repaired, the need for remake may be eliminated or postponed. Many different ceramic repair materials are available, and bond strength data are necessary for predicting the success of a given repair system.Purpose. This study evaluated the shear bond strength of different repair systems for metal-ceramic restorations applied on metal and porcelain.Material and methods. Fifty cylindrical specimens (9 X 3 mm) were fabricated in a nickel-chromium alloy (Vera Bond 11) and 50 in feldspathic porcelain (Noritakc). Metal (M) and porcelain (P) specimens were embedded in a polyvinyl chloride (PVC) ring and received I of the following bonding and resin composite repair systems (n=10): Clearfil SE Bond/Clearfil AP-X (CL), Bistite II DC/Palfique (BT), Cojet Sand/Z100 (Q), Scotchbond Multipurpose Plus/Z100 (SB) (control group), or Cojet Sand plus Scotchbond Multipurpose Plus/Z100 (CJSB). The specimens were stored in distilled water for 24 hours at 37 degrees C, thermal cycled (1000 cycles at 5 degrees C to 55 degrees C), and stored at 37 degrees C for 8 days. Shear bond tests between the metal or ceramic specimens and repair systems were performed in a mechanical testing machine with a crosshead speed of 0.5 mm/min. Mean shear bond strength values (MPa) were submitted to 1-way ANOVA and Tukey honestly significant difference tests (alpha=.05). Each specimen was examined under a stereoscopic lens with X 30 magnification, and mode of failure was classified as adhesive, cohesive, or a combination.Results. on metal, the mean shear bond strength values for the groups were as follows: MCL, 18.40 +/- 2.88(b); MBT, 8.57 +/- 1.00(d); MCJ, 25.24 +/- 3.46(a); MSB, 16.26 +/- 3.09(bc); and MCJSB, 13.11 +/- 1.24(c). on porcelain, the mean shear bond strength values ofeach group were as follows: PCL, 16.91 +/- 2.22(b); PBT, 18.04 +/- 3.2(ab); PCJ, 19.54 +/- 3.77(ab); PSB, 21.05 +/- 3.22(a); and PCJSB, 16.18 +/- 1.71(b). Within each substrate, identical superscript letters denote no significant differences among groups.Conclusions. The bond strength for the metal substrate was significantly higher using the Q system. For porcelain, SB, Q, and BT systems showed the highest shear bond strength values, and only SB was significantly different compared to CL and CJSB (P <.05).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study evaluated the shear bond strength (SBS) and stability of commercially pure titanium (CP Ti)/repair material interfaces promoted by different repair systems. One hundred CP Ti cast discs were divided into five repair system groups: 1) Epricord (EP); 2) Bistite 11 DC (BT); 3) Cojet (CJ); 4) Scotchbond Multi-Purpose Plus (SB) (control group); and 5) Cojet Sand plus Scotchbond Multi-Purpose Plus (CJSB). The specimens were stored in distilled water for 24 hours at 37 degrees C, thermal cycled (5000 cycles, 5 degrees-55 degrees C) and stored under the same conditions for either 24 hours or six months (n=10). SBS was tested and the data were analyzed by two-way analysis of variance (ANOVA) and Tukey test (alpha=.05). Failure mode was determined with a stereomicroscope (20x). The repair system, storage time, and their interaction significantly affected the SBS (p<0.001). At 24 hours, CJSB exhibited the highest SBS value, followed by CJ. At six months, these two groups had similar mean SBS (p>0.05) and higher means in comparison to the other groups. For both storage times, BT presented the lowest SBS, while the EP and SB groups did not differ significantly from one another (p>0.05). There were no significant differences in SBS between the storage times for the groups EP and CJ (p>0.05). The groups BT, SB, and CJSB showed 100% adhesive failure, irrespective of storage time. The CJSB group showed the highest SBS at both storage times. At six months, the CJ group exhibited a similar SBS mean value when compared to the CJSB group. Water storage adversely affected the groups BT, SB (control group), and CJSB. Considering SBS values, stability, and the failure mode simultaneously, the CJ group showed the best CP Ti repair performance.
Resumo:
Objectives:Microleakage is a pre-stage of debonding between hard chairside relines and denture base acrylic resins. Therefore, it is important to assess them with regard to the longevity of the relined denture. This study investigated the effect of thermal cycling on the microleakage at the interface of three hard chairside reline resins and three denture base resins.Material and methods:Rectangular bars (12 mm x 3 mm x 3 mm) of Lucitone 550, Acron MC and QC 20 were made and relined with Kooliner, Tokuyama Rebase Fast II and Ufi Gel Hard, Lucitone 550, Acron MC and QC 20 resins. Specimens were divided into one control and two test groups (n = 10). In specimens of the control group, the microleakage was performed after the reline procedure. In Test Group 1, the specimens were stored for 24 h in distilled water at room temperature and in Test Group 2; the specimens were thermal cycled from 5 to 55 degrees C for 5000 cycles with a 30-s dwell time. Subsequently, all specimens were immersed in 50% silver nitrate solutions for 24 h. All specimens were sectioned longitudinally into three fractions and the lateral sections were examined (n = 20). Silver nitrate stain penetration was examined under a stereoscopic lens with x30 magnification, and the images were captured. Leica Qwin image analysis software was used to determine microleakage at the interface of the materials. Data were analysed using the Kruskal-Wallis test at a 95% level of significance.Results:For all cycles, there were no statistically significant differences between thermal cycled and non-thermal cycled groups (p > 0.05).Conclusion:It can be concluded that thermal cycling had no effect on the microleakage.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)