13 resultados para cushion
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
In this paper, we demonstrate that the intrinsic electric field created by a poly(o-methoxyaniline) (POMA) cushion layer hinders the changes in molecular conformation of poly(p-phenylenevinylene) (PPV) in layer-by-layer with dodecylbenzene sulfonic acid (DBS). This was modeled with density functional theory (DFT) calculations where an energy barrier hampered molecular movements of PPV segments when they were subjected to an electric field comparable to that caused by a charged POMA layer. With restricted changes in molecular conformation, the PPV film exhibited Franck-Condon transitions and the photoexcitation spectra resembled the absorption spectra, in contrast to PPV/DBS films deposited directly on glass, with no POMA cushion. Other effects from the POMA cushion were the reduced number of structural defects, confirmed with Raman spectroscopy, and an enhanced PPV emission at high temperatures (300 K) in comparison with the films on bare glass. The positive effects from the POMA cushion may be exploited for enhanced opto-electronic devices, especially as the intrinsic electric field may assist in separating photoexcited electron-hole pairs in photovoltaic devices. © 2013 American Institute of Physics.
Resumo:
O objetivo deste estudo foi avaliar as alterações do aparato podotroclear de 22 cavalos da raça Quarto de Milha acometidos pela síndrome do navicular utilizando o acesso transcuneal. Esses equinos foram submetidos ao exame radiográfico e ultrassonográfico. No exame radiográfico foi observado a presença de invaginação sinovial de diferentes tipos, além de calcificação da bursa podotroclear e tendão flexor digital profundo, entesiófitos, osteófitos e alteração do limite córtico-medular. No exame ultrassonográfico observou-se alterações da bursa podotroclear, aderência e irregularidades nos bordos do tendão flexor digital profundo, diminuição do coxim digital, calcificação do ligamento sesamóide distal ímpar e irregularidade da superfície flexora do osso sesamóide distal. Todos os equinos que apresentavam alterações radiográficas também apresentaram alterações no exame ultrassonográfico compatíveis com a síndrome do navicular. O exame ultrassonográfico utilizando o acesso transcuneal foi um método prático e eficiente para avaliação das lesões do aparato podotroclear dos eqüinos, sendo um método complementar ao exame radiográfico.
Resumo:
Removal of excess seminal plasma is sometimes necessary to increase the quality and the longevity of cooled equine semen; moreover, this procedure is an indispensable step aiming to concentrate the sperm cells before freezing equine semen. Typically, the removal of seminal plasma is achieved by centrifugation; however, studies have shown that the force and duration of centrifugation can damage sperm cells and reduce the sperm recovery rate. Recently, new methodologies, such as cushion and filtration, have been described that aim to decrease the mechanical damage of centrifugation to sperm cells. This study aims to compare different methods for concentrating stallion semen.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: Intraperitoneal adhesions are common in equines, especially following exploratory celiotomy. Adhesiolysis is the treatment of choice for patients presenting postsurgical adhesions. Laparoscopic approach for adhesiolysis presents several advantageous aspects in human patients. The aim of the current study was to report a case of successful laparoscopic adhesiolysis in a mini pony horse. Case: A male Shetland Pony, weighing 140 kg, was admitted under complaint of right hind limb trauma and treated surgically for metatarsal fracture reduction. The patient has also had intermittent episodes of colic and was always treated clinically without major complications. The pony had no history of previous abdominal surgery and no episodes of acute abdomen were seen during hospital stay. Three months following ostheosynthesis, an exploratory laparoscopic approach was carried out to assess the possible cause or consequences of the episodes of acute abdomen. The patient was submitted to general anesthesia, positioned in dorsal recumbency and the abdomen was clipped and aseptically prepared for surgery. During the laparoscopic inspection, there were adhesions involving the ventral abdominal wall and a ventral mesogastric segment of duodenum. Laparoscopic adhesiolysis was performed using a two-port approach, by gently breaking the adhesion bands using meticulous traction with a 10-mm laparoscopic atraumatic Babcock forceps. Afterwards, the intestinal loop was rinsed with heparin sodium solution diluted in normal saline. The pneumoperitoneum was completely drained and the trocars sequentially withdrawn from the abdominal wall. The synthesis of the muscular layer was carried out using an interrupted cross mattress pattern, followed by synthesis of the skin with an interrupted cushion pattern. Total surgical time was 58 min. the patient was able to recover without complications. In the early postoperative period, the surgical recovery was considered excellent. No apparent adhesion involving the previously affected intestinal loop was found during the ultrasound exam following 15 days of surgery. Furthermore, the surgical wounds had healed completely, with no complications. Discussion: In the current case report, the primary cause of the acute abdomen episodes was not determined since the patient had never undergone abdominal surgery. It was hypothesized that an acute inflammation of the duodenal loop that was involved by the adhesion bands may have triggered the adhesiogenesis. Laparoscopy was efficient and presented a short operative time, due to magnification of image and adequate observation of structures surrounded by adhesion bands. Although the use of Babcock forceps is not usually recommended for adhesiolysis in the current literature, it was both effective in manipulating the bowel and performing the adhesiolysis. The heparin solution diluted in normal saline was effective in preventing the recurrence of new adhesions, which was evidenced by ultrasonography following 15 days. The laparoscopic approach usually minimizes the new formation of adhesions as trauma to the peritoneal surfaces is minimized by the use of delicate instruments, as observed in the current study. In addition, laparoscopy reduces the possibility of contact among the peritoneal surfaces and foreign bodies, such as gauze, glove powder and room air particles. Moreover, it maintains the abdominal surfaces in adequate humidity environment.
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Long term wheelchair usage has been related to a number of problems, among which pressure ulcers are one of most concern. The design of wheelchair seat cushions has been of increasing interest among researchers, as it can influence seat interface pressure and user's comfort. The aim of this study was to investigate the subjects' perception comfort, stability and body posture of six different commercially available wheelchair cushions. The evaluation was through a questionnaire, where the subjects rate their perceptions on a ten point visual analog scale after staying seated in the cushion for two minutes. The results shows that the RohoTM aircell cushion was preferred by the users, while the least preferred one was the water cushion. Individuals' subjective perceptions may compliment objective data on seat interface pressure, thus contributing to a more complete view of the users' experience during wheelchair cushion usage.
Resumo:
Cerebral paralysis is a chronic illness that affects the central nervous system. In this article the author describes the techniques used at CAOE (Odontological Center for Assistance to patients with special needs) to restraint CP patients during dental treatment, because they present some pathological reflexes which interfere in their odontological assistance. Also it shows how to perform a special physical restraint and how to keep the mouth open by using simple tools including a homemade one. All the devices used during the dental treatment in cerebral palsy patients, such as the physical restraint with bands or sheet to wrap them up, cylindrical pad or cushion made of a soft material, or simple tools including a homemade one to keep the mouth open are usually and safely used in CAOE. All these simple devices are necessary, because there are no available funds for the acquisition of expensive material or equipment. Despite of a shortage of resources we can easily and efficiently assist these patients.