63 resultados para contrast enhancement

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background. Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. Method. A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n=7) or 15 min (group 2; n=7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview®; Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. Results. Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. Conclusion. Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Contrast enhancement enables the verification of several pathological conditions that lead to vascular changes and/or breakdown of the blood-brain barrier. Examples of diseases that cause these disorders are: neoplastic diseases, vascular communications, active inflammation and cerebral ischemia. Several contrast enhancements located peripherically to cerebral lobes, in the topography of brain sulci and gyri, were identified on tomographic scan of twelve healthy cats that had their health confirmed through history, general and neurologic physical examination and polymerase chain reaction for feline leukemia (FeLV) and immunodeficiency (FIV) virus. This study aims to describe the tomographic contrast enhancement findings, which showed an identical appearance to the pia mater and arachnoid enhancement, also called leptomeninges. This finding is generally considered related to leptomeningeal diseases such as meningitis and neoplastic disease. However, in dogs, the leptomeningeal enhancement has already been described in healthy animals. This finding has a great importance in the interpretation of tomographic images of these animals since, so far, in the presence of these enhancements, meningeal disorders were suggested. Thus, the verification of other tomographic findings and the combination with other diagnostic methods are of great importance for the diagnosis of leptomeningeal disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Relata-se o diagnóstico de linfoma primário no sistema nervoso central em um cão Labrador Retrievier, de 10 anos de idade, que apresentava episódios convulsivos, incoordenação nos membros posteriores, head tilt, ataxia e sensibilidade diminuída no lado esquerdo. Constataram-se alterações laterais esquerdas, como ausências de propriocepção e de posicionamento tátil, alterações posteriores nas provas de carrinho de mão e de reação ao pulo e diminuição da extensão da postura e hemilocomoção. No líquido cefalorraquidiano (LCR), houve predomínio de linfócitos atípicos, caracterizados pela presença de anisocitose e anisocariose, nucléolos evidentes e anisonucleose, basofilia e microvacuolização citoplasmáticas, mitoses atípicas e corpúsculos linfoglandulares, compatíveis com linfoma, confirmado pelo exame histológico e imunocitoquímico, o qual revelou origem T, com expressão CD3+ e CD79-. A tomografia computadorizada não foi conclusiva e evidenciou diversas áreas hipodensas e intensificação de contraste na região de sulcos e giros do parênquima encefálico. A coleta do LCR foi essencial na rapidez do diagnóstico definitivo, indicando a natureza rara desta lesão primária.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The association of unilateral trochlear nerve palsy with Claude Bernard-Horner syndrome represents a rare clinical condition. We present the case of a patient with this unusual presentation. The investigation performed implicated cerebrovascular disease as the underlying cause of the condition in this patient. © 2011 S. Karger AG, Basel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cerebellum is responsible for coordination and maintenance of the fine control of muscle contraction. In cases of a suspected cerebellar disorder, a computed tomography scan can be performed to identify structural change. The aim of this study is to describe the cerebellar tomographic attenuation values in healthy cats since this variable is considered of great importance in the evaluation of images obtained by this imaging modality. A simple and a contrast enhanced brain computed tomographic scan were performed in 15 adult cats with no history of neurological symptoms and negative for feline leukemia and immunodeficiency virus. After acquiring the image, the measurement of the average attenuation of a cerebellar area of 2 centimeters in diameter was obtained. The cerebellar tomographic attenuation showed a variation from 14.60 to 25.50 HU in the simple scan and from 25.50 to 33.40 HU in the enhanced phase. Most animals (73.33%) had precontrast cerebellar attenuation values within the stipulated limit for the brain in a previous study (20-41 HU). Four animals in this study (26.67%) had values lower than 20 HU, which can be explained by differences in cellular composition between these two regions. The average value of contrast enhancement was 4.91 HU, and in none of the animals an enhancement greater than 10 HU was observed, which is in agreement with previous studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We exploit the possibility of new configurations in three-body halo nuclei, Samba type (the neutron-core form a bound system) as a doorway to Borromean systems. The nuclei Be-12, B-15, N-23 and F-27 are of such nature, in particular N-23 with a half-life of 37.7 s and a halo radius of 6.07 fm is an excellent example of Samba-halo configuration. The fusion below the barrier of the Samba halo nuclei with heavy targets could reveal the so far elusive enhancement and a dominance of one-neutron over two-neutron transfers, in contrast to what was found recently for the Borromean halo nucleus He-6 + U-238.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationships among avian uncoupling protein (avUCP) mRNA expression, heat production, and thyroid hormone metabolism were investigated in 7-14-day-old broiler chicks (Gallus gallus) exposed to a low temperature (cold-exposed chicks, CE) or a thermoneutral temperature (TN). After 7 days of exposure, CE chicks exhibited higher heat production (+83%, P < 0.01), avUCP mRNA expression (+20%, P < 0.01), and circulating triiodothyronine (T-3) levels (+104%, P = 0.07) for non-statistically different body weights and feed intake between 3 and 7 days of exposure as compared to TN chicks. Plasma thyroxine (T-4) concentration was clearly decreased in CE chicks (-33%, P = 0.06). The lower hepatic inner-ring deiodination activity (-47%) and the higher renal outer-ring deiodination activity (+75%) measured in CE compared to TN chicks could partly account for their higher plasma T3 concentrations. This study describes for the first time the induction of avUCP mRNA expression by low temperature in chickens, as it has been previously shown in ducklings, and supports the possible involvement of avUCP in avian thermogenesis. (C) 2003 Elsevier B.V. (USA). All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cellulose was extracted from lignocellulosic fibers and nanocrystalline cellulose (NC) prepared by alkali treatment of the fiber, steam explosion of the mercerized fiber, bleaching of the steam exploded fiber and finally acid treatment by 5% oxalic acid followed again by steam explosion. The average length and diameter of the NC were between 200-250 nm and 4-5 nm, respectively, in a monodisperse distribution. Different concentrations of the NC (0.1, 0.5, 1.0, 1.5, 2.0 and 2.5% by weight) were dispersed non-covalently into a completely bio-based thermoplastic polyurethane (TPU) derived entirely from oleic acid. The physical properties of the TPU nanocomposites were assessed by Fourier Transform Infra-Red spectroscopy (FTIR), Thermo-Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC), X-Ray Diffraction (XRD), Dynamic Mechanical Analysis (DMA) and Mechanical Properties Analysis. The nanocomposites demonstrated enhanced stress and elongation at break and improved thermal stability compared to the neat TPU. The best results were obtained with 0.5% of NC in the TPU. The elongation at break of this sample was improved from 178% to 269% and its stress at break from 29.3 to 40.5 MPa. In this and all other samples the glass transition temperature, melting temperature and crystallization behavior were essentially unaffected. This finding suggests a potential method of increasing the strength and the elongation at break of typically brittle and weak lipid-based TPUs without alteration of the other physico-chemical properties of the polymer. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen-deficient TiO2 films with enhanced visible and near-infrared optical absorption have been deposited by reactive sputtering using a planar diode radio frequency magnetron configuration. It is observed that the increase in the absorption coefficient is more effective when the O-2 gas supply is periodically interrupted rather than by a decrease of the partial O-2 gas pressure in the deposition plasma. The optical absorption coefficient at 1.5 eV increases from about 1 x 10(2) cm(-1) to more than 4 x 10(3) cm(-1) as a result of the gas flow discontinuity. A red-shift of similar to 0.24 eV in the optical absorption edge is also observed. High resolution transmission electron microscopy with composition analysis shows that the films present a dense columnar morphology, with estimated mean column width of 40nm. Moreover, the interruptions of the O-2 gas flow do not produce detectable variations in the film composition along its growing direction. X-ray diffraction and micro-Raman experiments indicate the presence of the TiO2 anatase, rutile, and brookite phases. The anatase phase is dominant, with a slight increment of the rutile and brookite phases in films deposited under discontinued O-2 gas flow. The increase of optical absorption in the visible and near-infrared regions has been attributed to a high density of defects in the TiO2 films, which is consistent with density functional theory calculations that place oxygen-related vacancy states in the upper third of the optical bandgap. The electronic structure calculation results, along with the adopted deposition method and experimental data, have been used to propose a mechanism to explain the formation of the observed oxygen-related defects in TiO2 thin films. The observed increase in sub-bandgap absorption and the modeling of the corresponding changes in the electronic structure are potentially useful concerning the optimization of efficiency of the photocatalytic activity and the magnetic doping of TiO2 films. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4724334]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)