102 resultados para coded aperture
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.
Resumo:
In this work, signal processing techniques are used to improve the quality of image based on multi-element synthetic aperture techniques. Using several apodization functions to obtain different side lobes distribution, a polarity function and a threshold criterium are used to develop an image compounding technique. The spatial diversity is increased using an additional array, which generates complementary information about the defects, improving the results of the proposed algorithm and producing high resolution and contrast images. The inspection of isotropic plate-like structures using linear arrays and Lamb waves is presented. Experimental results are shown for a 1-mm-thick isotropic aluminum plate with artificial defects using linear arrays formed by 30 piezoelectric elements, with the low dispersion symmetric mode S0 at the frequency of 330 kHz. © 2011 American Institute of Physics.
Resumo:
The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo deste trabalho foi determinar a posição e a profundidade de semeadura mais adequadas para a emergência de plântulas de açaizeiro. As sementes foram colocadas para germinar nas profundidades de 0; 3 e 6 cm e nas seguintes posições: sementes com a rafe perpendicular à superfície do substrato e poro germinativo para cima, rafe perpendicular e poro germinativo para baixo, rafe paralela à superfície e poro germinativo para baixo e rafe paralela à superfície e poro germinativo para cima. A emergência de plântulas de açaizeiro com a rafe perpendicular à superfície do substrato e poro germinativo para cima é a mais adequada, pois proporciona igual porcentagem e menor tempo médio de emergência. Profundidades iguais ou superiores a 3 cm são inadequadas para semeadura de Euterpe oleracea Mart.
Resumo:
Este trabalho teve como objetivo identificar zonas diferenciadas de manejo por meio de indicadores de fertilidade em Latossolos cultivados com cana-de-açúcar, utilizando-se a técnica de krigagem indicatriz, com vistas em buscar um aprimoramento na utilização de técnicas de agricultura de precisão. O estudo foi realizado em uma área de 90 ha pertencente a uma área maior de 1.900 ha, localizada em Jaboticabal, Estado de São Paulo, Brasil (21 ° 15 ' S e 48 ° 18 ' W). Na área experimental, foi estabelecida uma malha de amostragem regular de 50 m, com 420 pontos. em cada ponto, coletou-se uma amostra de solo, na qual foram determinados os teores de matéria orgânica, P, K disponíveis e o valor de V. Os dados obtidos para estas características do solo, assim como as combinações entre elas, foram codificados em valores indicadores 0 ou 1, conforme as variáveis apresentassem valores acima ou abaixo do valor de corte estabelecido, escolhido para cada variável, respectivamente. Os resultados propiciaram a confecção de mapas de probabilidade de cada variável (individual e combinada), o que possibilitou identificar regiões com diferentes níveis de fertilidade do solo na área experimental.
Resumo:
O sistema tradicional para estimativas de safra utiliza-se de relatórios técnicos de fontes diversas. A coleta de informações, se inicia antes da época do plantio e as estimativas são vendo ajustadas de acordo com o desenvolvimento das culturas. O trabalho em questão, pretende mostrar as possibilidades do filme infravermelho colorido na estimativa de safra para a cultura do milho. As informações quantitativas foram obtidas através da densitometria de transmissão. Os trabalhos foram conduzidos na Fazenda Experimental São Manuel da Faculdade de Ciências Agronômicas - Campus de Botucatu - UNESP. Os seis tratamentos consistiram em doses diferenciais de adubo, prevendo prováveis quedas em produção. A cultura foi fotografada com filme colorido (Kodak Ektachrome 64 ASA) e infravermelho colorido (Kodak Ektachrome Infrared Film) e a densidade ótica medida em um microdensitômetro de transmissão marca Weston, modelo 877 e abertura de 0,8 mm. Para avaliar a interação entre Produção e Densidade Ótica, utilizou-se das análises de correlação e regressão linear. A análise dos resultados permitiram as seguintes conclusões principais: a) Desde que se faça as necessárias calibrações, o filme infravermelho pode ser utilizado na estimativa de safra para a cultura do milho; b) A utilização do densitômetro de transmissão, para a interpretação quantitativa dos resultados, revelou-se importante sugerindo a aplicação do método em outros tipos de culturas.
Resumo:
The purpose of this paper was to evaluate attributes derived from fully polarimetric PALSAR data to discriminate and map macrophyte species in the Amazon floodplain wetlands. Fieldwork was carried out almost simultaneously to the radar acquisition, and macrophyte biomass and morphological variables were measured in the field. Attributes were calculated from the covariance matrix [C] derived from the single-look complex data. Image attributes and macrophyte variables were compared and analyzed to investigate the sensitivity of the attributes for discriminating among species. Based on these analyses, a rule-based classification was applied to map macrophyte species. Other classification approaches were tested and compared to the rule-based method: a classification based on the Freeman-Durden and Cloude-Pottier decomposition models, a hybrid classification (Wishart classifier with the input classes based on the H/a plane), and a statistical-based classification (supervised classification using Wishart distance measures). The findings show that attributes derived from fully polarimetric L-band data have good potential for discriminating herbaceous plant species based on morphology and that estimation of plant biomass and productivity could be improved by using these polarimetric attributes.
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
OBJECTIVES: To estimate oculometric parameters of Graves' ophthalmopathy in comparison to healthy eyes using digital photography and digital image analysis.INTRODUCTION: Graves' ophthalmopathy is the main cause of eye proptosis. Because these protrusions cause clinically perceived distortions in orbital architecture, digital photographs can be used to detect and quantify these changes.METHODS: We carried out a cross-sectional study comprising 12 healthy volunteers and 15 Graves' ophthalmopathy patients with the purpose of evaluating the use of simple, non-invasive digital photography to estimate oculometric parameters of Graves' ophthalmopathy and compare them with the parameters of unaffected eyes. Facial photographs of cases and controls were taken in a standardized manner. Oculometric parameters were compared between the groups and then correlated to proptometer measures.RESULTS: All estimated oculometric variables showed significant differences between the groups, in particular with regard to mediopupilar aperture, lateral height, distance from the iris edge to the lateral boundary of the palpebral fissure, and distance from the higher point of the iris to the lateral limit of the palpebral fissure. The product of medial aperture and horizontal palpebral fissure also revealed greater discrepancy between the groups. Proptometer measures showed significant linear correlation between the distance from the iris edge to the lateral boundary of the palpebral fissure and between the distance from the higher point of the iris to the lateral limit of palpebral fissure (p<0.05).CONCLUSIONS: Comparative analysis of oculometric parameters in Graves' ophthalmopathy suggests that eye proptosis is related to an asymmetric increase in lateral oculometric measures. Standardized digital photographs can be used in clinical practice to objectively estimate oculometric parameters of Graves' ophthalmopathy patients.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study evaluated the assumption that there are morphological differences between the natural anterior dentition of men and women. The goal of the study was to determine the gender of patients based on the appearance of the anterior teeth in photographs. Materials and Methods: Laymen and observers from different specialties were asked to determine the gender of individuals based on the shape and arrangement of anterior teeth. Forty anterior dentition photographs of dental students of both genders (20 women, 20 men) between 18 and 26 years old were selected, coded, and randomly arranged in an album. The albums were delivered to five groups of observers: general practitioners (recently graduated dentists), prosthodontists, orthodontists, restorative dentists (specialists in cosmetic and restorative dentistry), and laymen (control group). The observers evaluated the photographs twice at 1-week intervals. Results: The average correctly identified values in women and men were 57.6% and 58.8%, respectively. There was no statistical difference between observers and between each group of professionals and the laymen group (p > 0.05). An intraobserver agreement was not observed between the evaluations (kappa =-0.01). Conclusion: The results of this limited study indicated that it was not possible to differentiate gender by viewing photographs of anterior teeth.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of this study is to investigate the patterns of shell utilization in Petrochirus diogenes in the Ubatuba region, SP, Brazil. Hermit crabs were obtained from 1993 to 1996 with the aid of a shrimp fishery boat equipped with two double-rigged trawling nets. Shells were identified and weighed, and their maximum aperture width was measured. Hermit crabs were weighed, and their shield length was recorded. A total of 634 P. diogenes specimens, occupying shells of 12 gastropod species, was obtained. The shells of Tonna galea, Zidona dufresnei and Strombus pugilis were the most frequently occupied, the first marked by its larger aperture width and lower average weight. Small hermit crabs inhabited a wide variety of gastropod shells due to their higher availability. However, the utilization of T. galea shells became predominant as the crabs attained larger sizes. Differences in weight and aperture width are known to encourage certain shell utilization patterns and may affect growth and reproduction of hermit crabs.