43 resultados para burial depth

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Blowflies utilize discrete and ephemeral breeding sites for larval nutrition. After the exhaustion of food, larvae begin dispersing in search of sites to pupate or additional food sources, a process referred as postfeeding larval dispersal. Some of the most important aspects of this process were investigated in the blowfly Chrysomya albiceps, employing a circular arena to allow radial dispersion of larvae from the center. The results showed a positive correlation between burial depth and distance, and a negative correlation between distance and pupal weight. These results can be used in forensic entomology for the postmortem interval estimation of human corpses in medico-criminal investigations. (c) 2004 Elsevier B.V.. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blowflies use discrete and ephemeral substrates to feed their larva. After they run out of food, the larvae begin to disperse in order to find adequate places for pupation or additional food sources, a process named post-feeding larval dispersal. Briefly state the aspects and why they are important were studied in a circular arena of 25 cm in diameter and covered with wood shavings to a height of 40 cm allowing post-feeding dispersal from the center of the arena. Larvae of both Chrysomya albiceps and C. megacephala were used in five experiments for each species. For each pupa location, determined as distance from the center, depth, and weight were evaluated. Statistical tests were done to verify the relation between weight, depth and distance for pupation and for larvae of two species shows that the media distance is significantly different for two species and for C. megacephala this distance is greater than the distance for C. albiceps. The depth too is different for each species, as the larvae of C. megacephala buries deeper than C. albiceps. With relation of weight, there is no statistic evidence that have any difference between weights for pupation for each species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The parameter time-depth index (TDI) is applied in this study to quantify empirically the influence of burial history on sandstone porosity evolution. The TDI, expressed in kilometers per million years of age, is defined as the area in the burial history diagram enclosed by the burial curve of the reservoir and the axes of the diagram. In practice, reservoir depths during burial history are integrated at regular time intervals of 1 m.y. The calculations exclude present-day bathymetry or paleobathymetry. Sandstone reservoirs from several sedimentary basins along the Brazilian continental margin (Santos, Campos, Espírito Santo, Cumuruxatiba, Recôncavo, Sergipe, Alagoas, and Potiguar) were analyzed to investigate the evolution of porosity against TDI. These Upper Jurassic to Tertiary sandstones lie in depths of 700 to 4900 m, and are hydrocarbon charged (oil or gas). Average porosities of most of these reservoirs were obtained from core analysis, and a few porosity data were taken from well log interpretations. Detrital constituents of the sandstones are mainly quartz, feldspar, and granitic/gneissic rock fragments. Sandstones were grouped into three main reservoir types, based on composition (detrital quartz content) and grain sorting: Type I (average quartz content <50%) are very coarse grained to conglomeratic, poorly to very poorly sorted lithic arkoses. Rock fragments are mainly granitic/gneissic and coarse grained. Type II (average quartz content ranging from 50% to 70%) are fine- to coarse-grained (pebbles absent or occurring in small percentages), moderately sorted arkoses. Type III (average quartz content >80%) are fine to coarse, moderately to poorly sorted quartz arenites or subarkoses. Plots of average porosity against depth show great dispersion in porosity values; such dispersion is mostly due to differences in the reservoir burial histories. However, plotting porosity values against the TDI for individual reservoir types produces well-defined trends. The decrease in porosity is less marked in Type III reservoirs, intermediate in Type II, and faster in Type I. Such plots suggest that it is possible to make relatively accurate porosity predictions based on reservoir TDI, texture, and composition,: within the constraints of reservoir depth/age and basin tectonics analyzed in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stretch zone width (SZW) data for 15-5PH steel CTOD specimens fractured at -150 degrees C to + 23 degrees C temperature were measured based on focused images and 3D maps obtained by extended depth-of-field reconstruction from light microscopy (LM) image stacks. This LM-based method, with a larger lateral resolution, seems to be as effective for quantitative analysis of SZW as scanning electron microscopy (SEM) or confocal scanning laser microscopy (CSLM), permitting to clearly identify stretch zone boundaries. Despite the worst sharpness of focused images, a robust linear correlation was established to fracture toughness (KC) and SZW data for the 15-5PH steel tested specimens, measured at their center region. The method is an alternative to evaluate the boundaries of stretched zones, at a lower cost of implementation and training, since topographic data from elevation maps can be associated with reconstructed image, which summarizes the original contrast and brightness information. Finally, the extended depth-of-field method is presented here as a valuable tool for failure analysis, as a cheaper alternative to investigate rough surfaces or fracture, compared to scanning electron or confocal light microscopes. Microsc. Res. Tech. 75:11551158, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ETISO) concentration and compare the use of 3 BIS sensor positions in dogs.Animals-6 adult dogs.Procedures-Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ETISO concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET, so concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions).Results-The BIS and ETISO concentration were poorly correlated-, regardless of sensor positioning, mean BIS values did not change significantly as ETISO was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ.Conclusions and Clinical Relevance-In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the relationship between laser fluorescence values and sealant penetration depth on occlusal fissures. One hundred and sixty-six permanent molars were selected and divided into four groups, which were each treated using a different sealant (two clear and two opaque). The teeth were independently measured twice by two experienced dentists using two laser fluorescence devices-DIAGNOdent (LF and LFpen)-before and after sealing, and then thermoclycled. After measuring, the teeth were histologically prepared and assessed for caries extension. Digital photographs of the cut sealed sites were assessed, and the sealant penetration depth was measured. All 166 sites were measured by one of the examiners taking as limits the outer and inner surface of the sealant into the fissure. For each device (LF and LFpen) and each group, the difference between the values at baseline and after sealing was plotted against the sealant penetration depth and scatter plots were provided. It could be observed that most of the points were concentrated around the zero line, for both LF and LFpen in the four groups. In conclusion, there is no relation between changes in DIAGNOdent values and increasing of depth sealant penetration within the occlusal fissures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.