48 resultados para borehole carbon correction factor (avogadro units)

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Um método de correção de interferência espectral e de transporte é proposto, e foi aplicado para minimizar interferências por moléculas de PO produzidas em chama ar-acetileno e de transporte causada pela variação da concentração de ácido fosfórico. Átomos de Pb e moléculas de PO absorvem a 217,0005 nm, então Atotal217,0005 nm = A Pb217,0005 nm + A PO217,0005 nm. Monitorando o comprimento de onda alternativo de PO em 217,0458 nm, é possível calcular a contribuição relativa de PO na absorbância total a 217,0005 nm: A Pb217,0005 nm = Atotal217,0005 nm - A PO217,0005 nm = Atotal217,0005 nm - k (A PO217,0458 nm). O fator de correção k é a razão entre os coeficientes angulares de duas curvas analíticas para P obtidas a 217,0005 e 217,0458 nm (k = b217,0005 nm/b217,0458 nm). Fixando-se a taxa de aspiração da amostra em 5,0 ml min-1, e integrando-se a absorbância no comprimento de onda a 3 pixels, curvas analíticas para Pb (0,1 - 1,0 mg L-1) foram obtidas com coeficientes de correlação típicos > 0,9990. As correlações lineares entre absorbância e concentração de P nos comprimentos de onda 217,0005 e 217,0458 foram > 0,998. O limite de detecção de Pb foi 10 µg L-1. O método de correção proposto forneceu desvios padrão relativos (n=12) de 2,0 a 6,0%, ligeiramente menores que os obtidos sem correção (1,4-4,3%). As recuperações de Pb adicionado às amostras de ácido fosfórico variaram de 97,5 a 100% (com correção pelo método proposto) e de 105 a 230% (sem correção).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo do presente estudo foi verificar possíveis alterações nas proteínas de fase aguda em ovinos infectados experimentalmente com Trypanosoma vivax. Para tanto, foram utilizados oito ovinos machos, sendo quatro usados como controle e quatro infectados com 10(5) tripomastigotas de T. vivax. Colheram-se amostras de sangue em dois tempos antes da infecção e, posteriormente, aos 5, 7, 9, 11, 13, 15, 20, 30, 45, 60, 75, 90, 105 e 120 dias após a infecção (dpi); após centrifugação e aliquotização das amostras. As proteínas de fase aguda foram separadas por eletroforese em gel de acrilamida, contendo dodecil sulfato de sódio, e suas concentrações foram determinadas através de densitometria computadorizada. A dosagem de proteína total foi realizada pelo método colorimétrico do biureto. A contagem dos tripanossomas foi realizada diariamente, utilizando-se uma alíquota de 5 µL de sangue disperso em lâmina de microscopia, sob lamínula de 22 × 22 mm, contando-se os parasitos em 100 campos microscópicos, com objetiva de 40×, multiplicados pelo fator de correção do microscópio, e o resultado expresso em parasitos por mL de sangue. Para a análise estatística, empregou-se o teste de Wilcoxon a 5% de probabilidade. Foi observada a diminuição de diversas proteínas de fase aguda e aumento de antitripsina e transferrina que podem ser utilizadas para auxiliar no diagnóstico da infecção por T. vivax, principalmente na fase crônica da infecção.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Pesquisar um fator de correção para avaliação do erro refrativo sem a utilização da cicloplegia. MÉTODOS: Foram estudados 623 pacientes (1.246 olhos), de ambos os sexos, com idade entre 3 e 40 anos. As refratometrias estática e dinâmica foram obtidas usando-se o refrator automático Shin-Nippon Accuref-K 9001. A cicloplegia foi obtida com a instilação de uma gota de colírio ciclopentolato a 1%, com refratometria estática 30 minutos após. Os dados foram submetidos à análise estatística usando a técnica do modelo de regressão linear e modelo de regressão múltipla do valor dióptrico com e sem cicloplegia, em função da idade. RESULTADOS: A correlação entre valores dióptricos sem e com cicloplegia quanto ao erro astigmático variou de 81,52% a 92,27%. Quanto ao valor dióptrico esférico, a correlação foi menor (53,57% a 87,78%). O mesmo se observou em relação ao eixo do astigmatismo (28,86% a 58,80%). O modelo de regressão múltipla em função da idade mostrou coeficiente de determinação múltiplo maior para a miopia (86,38%) e astigmatismo (79,79%). O menor coeficiente foi observado para o eixo do astigmatismo (17,70%). CONCLUSÃO: Avaliando-se os erros refrativos com e sem cicloplegia, observou-se alta correlação nas ametropias cilíndricas. Foram desenvolvidas equações matemáticas como fator de correção para refratometrias dos pacientes sem cicloplegia, portadores de ametropias cilíndricas e esféricas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the reliability of the standing measurement of hand-to-foot bioimpedance compared with measurements made in the lying position.Research Methods and Procedures: In 205 volunteers 6 to 89 years of age, 111 males and 94 females from six ethnic groups, effects of posture, time, and age on hand-to-foot resistance were studied over a range of body size. The effect of time in a position on resistance was also recorded in a small subset (n = 10), and repeat measurements over 3 days at the same time of the day were recorded in another subset (n = 12).Results: Lying impedance was consistently higher than standing, with the relationship (resistance lying/resistance standing) for the children (5 to 14 years) being 1.031, progressing to a ratio of 1.016 in those >60 years. The time spent static in either position did change resistance measurements - a decrease of up to 9 Omega (mean 5 Omega, 1.0%) over 10 minutes of standing and an increase of up to 7 Omega (mean 3 Omega, 0.7%) with lying.Discussion: In the field, measurements of hand-to-foot bioimpedance can be made in the standing position, and, with appropriate adjustment, previously validated recumbent equations can be used. Given that errors in the measurement of height and weight also affect the reliability of the derivation of body fat from bioelectrical conductance, the errors that may arise from a more practical standing measurement rather than lying are minimal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new shadow-ring device for measuring diffuse solar radiation at the surface is presented. In this device the seasonal variation of shadow is followed by moving the detector horizontally. This unique characteristic facilitates its application for long and continuous periods of time. The blocking effect caused by the ring and other related geometric properties are formulated considering the diffuse solar radiation isotropic. The correction factor, shadow size, and ring-detector distance are derived as a function of radius and width of the ring, sun position, and local latitude. The largest blocking occurs during summer, when the ring-detector distance and the shadow width are the smallest, and it is compensated by a smaller blocking effect in the winter period. The performance of the new device is verified comparing daily values of diffuse solar radiation measured simultaneously with a similar device from Kipp & Zonen, Inc. The results show a very good agreement (within 2.5%) between both devices. The new device was also able to reproduce the radiometric properties of the local atmosphere based on 3-yr-long measurements of direct solar radiation using a pyrheliometer. The new device can be applied to estimate daily values of diffuse solar radiation at the surface in the range of 30degreesN-30degreesS with results comparable to other similar apparatuses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heat capacities of binary aqueous solutions of different concentrations of sucrose, glucose, fructose, citric acid, malic acid, and inorganic salts were measured with a differential scanning calorimeter in the temperature range from 5degreesC to 65degreesC. Heat capacity increased with increasing water content and increasing temperature. At low concentrations, heat capacity approached that of pure water, with a less pronounced effect of temperature, and similar abnormal behavior of pure water with a minimum around 30degreesC-40degreesC. Literature data, when available agreed relatively well with experimental values. A correction factor, based on the assumption of chemical equilibrium between liquid and gas phase in the Differential Scanning Calorimeter, was proposed to correct for the water evaporation due to temperature rise. Experimental data were fitted to predictive models. Excess molar heat capacity was calculated using the Redlich-Kister equation to represent the deviation from the additive ideal model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cost of maintenance makes up a large part of total energy costs in ruminants. Metabolizable energy (ME) requirement for maintenance (MEm) is the daily ME intake that exactly balances heat energy (HE). The net energy requirement for maintenance (NEm) is estimated subtracting MEm from the HE produced by the processing of the diet. Men cannot be directly measured experimentally and is estimated by measuring basal metabolism in fasted animals or by regression measuring the recovered energy in fed animals. MEm and NEm usually, but not always, are expressed in terms of BW0.75. However, this scaling factor is substantially empirical and its exponent is often inadequate, especially for growing animals. MEm estimated by different feeding systems (AFRC, CNCPS, CSIRO, INRA, NRC) were compared by using dairy cattle data. The comparison showed that these systems differ in the approaches used to estimate MEm and for its quantification. The CSIRO system estimated the highest MEm, mostly because it includes a correction factor to increase ME as the feeding level increases. Relative to CSIRO estimates, those of NRC, INRA, CNCPS, and AFRC were on average 0.92, 0.86, 0.84, and 0.78, respectively. MEm is affected by the previous nutritional history of the animals. This phenomenon is best predicted by dynamic models, of which several have been published in the last decades. They are based either on energy flows or on nutrient flows. Some of the different approaches used were described and discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine a shape factor to estimate area of leaflets of two peanut cultivars (IAC TATU ST, IAC RUNNER 886). Correlation studies were conducted involving real leaf area (Sf) and leaf length (C), maximum leaf width (L) and the product between C and L. For each cultivar was determined a form factor (f) by means of regression analysis between the product of the length by the width and the actual area of leaves and the correlation between leaf area estimated by the correction factor and direct measurement. All evaluated models (linear, exponential or geometric) provided good estimates of leaf area (above 87%). Linear models had the best fit, passing or not through the origin. From a practical viewpoint, it is suggested to use the linear model involving the C and L product, using a linear coefficient equal to zero, with values of factor f equal to 0.7111 and 0.7266 for IAC RUNNER 886 and IAC TATU ST, respectively. The method of dimensions is feasible for the estimation of leaf area for both peanut cultivars, for showing good r(2) values (0.97), with errors below 3%, even when used with independent data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A monitoring network of atmospheric electric field covering the Vale do Paraiba region was implemented. The sensors were located on different sites with different altitude and geographic topology. The present work reports the study carried on those sensors in order to verify the necessity of using some correction factor to the measured local electric field intensity due to effects of local environment. The measurements were done in continuous 24 hours per day with the data recorded on registers in each device accumulating information during a period of four months. The relation between the electric field values by each sensor was compared to the reference located on Sao Jose dos Campos city using the same period. In a graphical analysis using the local field intensity and the reference, the data were fitted to a straight line obtained by minimum square method. Variation up to 95% was observed between the field values in some sensors. Another method was proposed, comparing the mean values of the electric field in a function of time. The variation in some sensors reached up to 133%. We conclude that the variations are due to local atmospheric conditions and no correction factor is required on the electric field sensors

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)