48 resultados para audiovisual equipment
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The author suggests a long-distance teaching on toxinology using the following media: conventional printed book, scientific electronic journal, video library and the Internet. These new media are discussed as new alternatives for long-distance learning without the teacher.
Resumo:
The aim of the present study is to assess the behaviour of different motivation methods on levels of oral hygiene among schoolchildren aged from 7 to 9 years in Araraquara, SP, Brazil. The methods tested were: indirect instruction using 'The Smiling Robot' (group I), indirect instruction through class presentation (group II) and direct instruction with macromodels (group III). A control group was also constituted, which received no kind of motivation (group IV). The O'Leary Plaque Index was used as the evaluation method, applied before the instruction and 30 days after application of the different methods. It was noted that the plaque index had not decreased in group IV only. In conclusion, all the motivation methods promoted significant decrease of plaque index and among these methods, the 'The Smiling Robot' was the one that provided the best results.
Resumo:
O uso de recursos audiovisuais no ensino de solos, como estímulo para os alunos, pode auxiliar na construção de um conhecimento crítico e reflexivo. Este trabalho objetivou analisar a contribuição do vídeo Conhecendo o Solo no ensino e na aprendizagem dessa temática no nível fundamental. Com o intuito de estimular os alunos a perceber a importância dos solos nos ambientes, esse vídeo foi aplicado como conteúdo de ensino. em seguida, foi aplicado um questionário, em que os alunos descreveram as principais ideias transmitidas por esse, especificando os pontos positivos e negativos do recurso utilizado. A análise do questionário revelou que o uso do vídeo foi um facilitador da aprendizagem. Porém, as respostas dos estudantes indicaram que alguns aspectos necessitam de adequações, como o dinamismo, a interatividade, a quantidade de informações e a narração. Mesmo assim, o recurso foi classificado pela maioria dos alunos como adequado, e o repertório de conteúdos apresentou similaridade com o exposto no vídeo, caracterizando-o como um recurso de influência positiva no processo de ensino e aprendizagem.
Resumo:
Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.
Resumo:
The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.
Resumo:
It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.
Resumo:
The origin of the concept of cultural heritage and its definition and applicability to the Brazilian scenery is analyzed, with a focus on audiovisual archives.
Design of personal protective equipment: To promote of Brazilian artefacts with ergonomic attributes
Resumo:
This research aims to investigate a topic sometimes overlooked among the research of ergonomics. Particularly, we treat the garments as personal protective equipment. In this study we abode on clothing produced and used in Brazil, making notes about the management of occupational safety for the use of such equipment. In turn, identify Relevant requirements for the design of personal protective equipment used in Brazil, in line with what is being studied in global forums on the subject. © 2013 Taylor & Francis Group.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)