86 resultados para anaerobic conditions in sewer systems

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One-day-old broiler chicks received cecal microflora (CM) cultured under aerobic, anaerobic conditions, or both (mixed) and were then infected with Salmonella Enteritidis, in order to compare the efficacy of these different types of culture in terms of the number of chicks infected, cecal colonization and faecal excretion of the challenging bacteria. Regardless of culture type, CM always led to a smaller number of S. Enteritidis for any of the parameters studied compared to untreated chicks. Aerobic CM demonstrated better efficacy in reducing the number of infected chicks and cecal colonization by S. Enteritidis, followed by mixed CM. No difference was observed in faecal excretion of S. Enteritidis between the chicks that received different types of CM culture. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a new approach to minimize the losses in electrical power systems. This approach considers the application of the primal-dual logarithmic barrier method to voltage magnitude and tap-changing transformer variables, and the other inequality constraints are treated by augmented Lagrangian method. The Lagrangian function aggregates all the constraints. The first-order necessary conditions are reached by Newton's method, and by updating the dual variables and penalty factors. Test results are presented to show the good performance of this approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a new three-phase transformer modeling suitable for simulations in Pspice environment, which until now represents the electrical characteristics of a real transformer. It is proposed the model comparison to a three-phase transformer modeling present in EMTP - ATP program, which includes the electrical and magnetic characteristics. In addition, a set including non-linear loads and a real three-phase transformer was prepared in order to compare and validate the results of this new proposed model. The three-phase Pspice transformer modeling, different from the conventional one using inductance coupling, is remarkable for its simplicity and ease in simulation process, since it uses available voltage and current sources present in Pspice program, enabling simulations of three-phase network system including the most common configuration, three wires in the primary side and four wires in the secondary side (three-phases and neutral). Finally, the proposed modeling becomes a powerful tool for three-phase network simulations due to its simplicity and accuracy, able to simulate and analyze harmonic flow in three-phase systems under balanced and unbalanced conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermoeconomic Functional Analysis is a method developed for the analysis and optimal design of improvement of thermal systems (Frangopoulos, 1984). The purpose of this work is to discuss the cogeneration system optimization using a condensing steam turbine with two extractions. This cogeneration system is a rational alternative in pulp and paper plants in regard to the Brazilian conditions. The objective of this optimization consists of minimizing the global cost of the system acquisition and operation, based on the parametrization of actual data from a cellulose plant with a daily production of 1000 tons. Among the several possible decision variables, the pressure and temperature of live steam were selected. These variables significantly affect the energy performance of the cogeneration system. The conditions which determine a lower cost for the system are presented in conclusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aiming to assess the presence of selected anaerobic microorganisms in root canals of human teeth with chronic apical periodontitis, 25 central and lateral upper incisors presenting with radiographic evidence of chronic apical periodontitis were studied. The pulp chamber was opened under aseptic conditions and samples of the root canal content were collected with sterile absorbent paper points, which were placed and dispersed in test tubes containing reduced transport medium (RTF). Aliquots were dried on glass slides and stained by indirect immunofluorcscencc for detection of Actinomyces viscosus, Fusobacterium nucleatum, Porphyromonas gingivalis and Prevotella intermedia. The results showed a positive indirect immunofluorescence reaction in 24 of the 25 samples. Fourteen were positive for the specie Actinomyces viscosus, 12 for Prevotella intermedia, 10 for Fusobacterium nucleatum and 4 for Porphyromonas gingivalis. A semiquantitative assay was easily implemented for assessment of degree of infection by the organisms in individual cases. © Munksgaard, 1996.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The factors that have influence on the energy consumption of a small air conditioning system that are worth mentioning are the efficiencies of the compressor, evaporator and condenser, the form that the refrigerant flow is controlled, the fan model used, and climatic conditions. Within the climate issue, an interesting factor is that the relative humidity when it comes to the effect that it causes, especially in the performance of the air condenser, which generally is not considered in the projects. This study aims to evaluate the influence of humidity on the coefficient of system performance (COP), seeking to quantify their influence when it happens. The tests were performed on a testing bench, mounted at the Laboratory for Energy Efficiency (LAMOTRIZ) UNESP-Campus Guaratinguetá. In the study, the wet bulb temperature was ranged, keeping the rotation of the scroll compressor with application of a frequency inverter in its best performance. The test bench is provided with a supervisory system of data collection that is also able to control all functions of the bench. In the results, there was a significant influence, particularly when comparing high humidity conditions with low humidity, noting that only over 65% relative humidity is that significant changes are observed in the COP of the system. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to analyze the spatial distribution of dengue risk and its association with socio-environmental conditions. This was an ecological study of the counts of autochthonous dengue cases in the municipality of Campinas, São Paulo State, Brazil, in the year 2007, aggregated according to 47 coverage areas of municipal health centers. Spatial models for mapping diseases were constructed with Bayesian hierarchical models, based on Integrated Nested Laplace Approximation (INLA). The analyses were stratified according to two age groups, 0 to 14 years and above 14 years. The results indicate that the spatial distribution of dengue risk is not associated with socio-environmental conditions in the 0 to 14 year age group. In the age group older than 14 years, the relative risk of dengue increases significantly as the level of socio-environmental deprivation increases. Mapping of socio-environmental deprivation and dengue cases proved to be a useful tool for data analysis in dengue surveillance systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new procedure was developed in this study, based on a system equipped with a cellulose membrane and a tetraethylenepentamine hexaacetate chelator (MD-TEPHA) for in situ characterization of the lability of metal species in aquatic systems. To this end, the DM-TEPHA system was prepared by adding TEPHA chelator to cellulose bags pre-purified with 1.0 mol L-1 of HCl and NaOH solutions. After the MD-TEPHA system was sealed, it was examined in the laboratory to evaluate the influence of complexation time (0-24 h), pH (3.0, 4.0, 5.0, 6.0 and 7.0), metal ions (Cu, Cd, Fe, Mn and Ni) and concentration of organic matter (15, 30 and 60 mg L-1) on the relative lability of metal species by TEPHA chelator. The results showed that Fe and Cu metals were complexed more slowly by TEPHA chelator in the MD-TEPHA system than were Cd, Ni and Mn in all pH used. It was also found that the pH strongly influences the process of metal complexation by the MD-TEPHA system. At all the pH levels, Cd, Mn and Ni showed greater complexation with TEPHA chelator (recovery of about 95-75%) than did Cu and Fe metals. Time also affects the lability of metal species complexed by aquatic humic substances (AHS); while Cd, Ni and Mn showed a faster kinetics, reaching equilibrium after about 100 min, and Cu and Fe approached equilibrium after 400 min. Increasing the AHS concentration decreases the lability of metal species by shifting the equilibrium to AHS-metal complexes. Our results indicate that the system under study offers an interesting alternative that can be applied to in situ experiments for differentiation of labile and inert metal species in aquatic systems. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was conducted on the effects of acute administration of aminophylline on physiological variables in purebred Arabian horses submitted to incremental exercise test. Twelve horses were submitted to two physical tests separated by a 10-day interval in a crossover study. These horses were divided into two groups: control (C, n = 12) and aminophylline (AM, n = 12). The drug at 10 mg/kg body weight or saline was given intravenously, 30 minutes before the incremental exercise test. The treadmill exercise test consisted of an initial warmup followed by gradually increasing physical exigency. Blood samples were assayed for lactic acid, glucose, and insulin. Maximal lactic acidemia was greater (P = .0238) in the AM group. Both V-2 and V-4 (velocities at which lactate concentrations were 2 and 4 mmol/ L, respectively) were reduced in the AM group by 15.85% (P = .0402) and 17.76% (P = .0 109), respectively. At rest as well as at 4 minutes, insulinemia was greater in the AM group (P = .0417 and .0393), Glycemia group at times 8 was statistically lower in the Al (P = .0138) and 10 minutes (P = .0432). Use of ammophylline in horses during incremental exercise does not seem to be beneficial, because this drug has a tendency to cause hypoglycemia and to increase dependence on anaerobic glucose metabolism.