40 resultados para aguas subterráneas

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Water management has in the watershed plans an important tool to plan the territory and adjust the activities develop over it to the natural resources availability. The incorporation of uncertainty analysis associated with hydrological modelling predictions is a manner to simulate scenarios and work with chances and probabilities that certain events happens inside these plans. Using stochastic methods is possible to consider uncertainty from estimations and even model it. Stochastic methods developed considerably during the last 30 years, but its applications to real-world problems have been limited, and did not turn into routine in hydrology. This paper brings an overview from eminent hydrologists about this subject and discuss the Brazilian and Paulista situation in the scope of groundwater monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The numeric simulation is an important tool applied in understanding the dynamics of groundwater flow. In a hydrogeological model the processes responsible for groundwater flow are described by numerical formulations that allow the simplification, representation and understanding of the dynamics of the Aquifer System. In this work, a steady state groundwater flow simulation of Urucuia Aquifer System (UAS) part of the Corrente river basin was conducted, using the finite element method through software FEFLOW, to understand the dynamics of groundwater flow and quantify the hydrologic balance. The aquifer system Urucuia lodges in the São Francisco hydrogeological province and corresponds to a set of interconnected aquifers that occur in rocks from Urucuia group in the Urucuia sub-basin described by Campos e Dardenne (1997). The system is a porous media one, in a shape of a thick table mountain, consisting essentially of sandstones. The Corrente river basin is located in UAS in Western State of Bahia and it's one of the main units to maintaining permanent flow (Q95) and average natural flow of the São Francisco river. The simulation performed in this work obtained the following results for the modelled region: horizontal hydraulic conductivity of 3 x 10-4 m/s and vertical one 6 x 10-5 m/s; maximum recharge of 345 mm and minimum of 85 mm/a. It was concluded that: (1) regional groundwater flow has eastbound; with an exception of the extreme northeast portion, where the flow has opposite direction; (2) there are smaller water side dividers with an approximate direction EW, that guide the flow of water to the drainage that cut the aquifer; and (3) the UAS at Corrente river basin can be understood as a free regional aquifer system, isotropic and homogeneous. Regionally, the small lithological variations present in the Urucuia group can be neglected and do not exhibit significant influences on the dynamics of ground water flow

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The water management in any area is highly important to the success of many business and also of life and the understanding of your relationship with the environment brings better control to its demand. I.e. hydrogeological studies are needed under better understanding of the behavior of an aquifer, so that its management is done so as not to deplete or harm it. The objective of this work is the numerical modeling in transient regime of a portion of the Rio Claro aquifer formation in order to get answers about its hydrogeological parameters, its main flow direction and also its most sensitive parameters. A literature review and conceptual characterization of the aquifer, combined with field campaigns and monitoring of local water level (NA), enabled the subsequent construction of the mathematical model by finite elements method, using the FEFLOW 6.1 ® computational algorithm. The study site includes the campus of UNESP and residential and industrial areas of Rio Claro city. Its area of 9.73 km ² was divided into 318040 triangular elements spread over six layers, totaling a volume of 0.25 km³. The local topography and geological contacts were obtained from previous geological and geophysical studies as well as profiles of campus wells and SIAGAS / CPRM system. The seven monitoring wells on campus were set up as observation points for calibration and checking of the simulation results. Sampling and characterization of Rio Claro sandstones shows up a high hydrological and lithological heterogeneity for the aquifer formation. The simulation results indicate values of hydraulic conductivity between 10-6 and 10-4 m / s, getting the Recharge/Rainfall simulation in transient ratio at 13%. Even with the simplifications imposed on the model, it was able to represent the fluctuations of local NA over a year of monitoring. The result was the exit of 3774770 m³ of water and the consequently NA fall. The model is considered representative for the...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A discussion about groundwater contamination is presented in this work. Contamination by agricultural activity, more specifically by pesticides is emphasized. Indirect and direct estimates could be used to predict pesticide behavior in soil, and consequently, to evaluate the potential of groundwater contamination. These results could be applied to advise about the possibility of groundwater contamination by pesticides, and to provide subsidies for making decisions more quickly and efficiently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cidade de Manaus está localizada numa região próxima ao centro da bacia Amazônica, cujo abastecimento de água é realizado pelas águas do Amazonas, sendo efetuado por captação da drenagem superficial do rio Negro e por poços tubulares, que exploram aqüíferos constituídos pela Formação Alter do Chão. Com o objetivo de investigar a hidroquímica das águas subterrâneas de Manaus, para caracterizar e avaliar a qualidade dos recursos hídricos em subsuperfície, aferiram-se os parâmetros físicos, físico-químicos e químicos das amostras de águas de poços tubulares selecionados. Os resultados obtidos dos parâmetros analisados mostraram que as águas estudadas são excelentes para consumo humano e industrial, por situarem-se dentro dos limites de potabilidade estabelecidos pela legislação vigente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Springwater samples were collected at Aguas da Prata, an important spa in São Paulo State, Brazil. The U-238 and U-234 isotopes were evaluated for Platina, Paiol, Villela, Prata-Radioativa, Prata-Nova, Boi, Vitoria, and Prata-Antiga springs. An inverse logarithmic correlation was found between U-234/U-238 activity ratio and Rn-222 content of the studied waters, which was related to different solution mechanisms of Rn-222 and U-234 nuclides at the rock-water interface. A linear correlation also exists between the U-234/U-238 activity ratios of the studied waters and total dissolved solids, ionic strength, CO2 partial pressure, and index of base exchange, which indicates that the enhancement of U-234 in solution increases with the degree of weathering in the aquifers, A higher U-234/U-238 activity ratio was found to be directly related to a higher value of dissolution rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Thermal Corridor of Uruguay River is located in the triple border of Argentine, Brazil and Uruguay, and shows an intense economic thermal tourism activity, mainly based on groundwaters from Guarani Aquifer System (GAS). Recent studies have pointed out the occurrence of high concentrations of arsenic (>10 μg/L) in GAS groundwater in this area. The complex geological and hydrogeological framework in the area is associated to the Paraná Basin geological evolution south of the Assuncion-Rio Grande Arch; it encompass paleozoic marine sequences and continental sequences permian/eotriassic to mesozoic in age, which are covered by basaltic lavas of Serra Geral Formation. Iron oxide coatings have been described in sandstones of Buena Vista and Sanga do Cabral formations, which underlie GAS units. Arsenic occurrence is associated to sodium bicarbonate groundwater with pH values over 8.0. Arsenic is released to groundwater by desorption from iron oxides/hydroxides, as result of the higher pH of these waters, indicating that arsenic is released from the units that underlie GAS units. Increase in chromium and uranium concentrations are also related to high pH groundwaters, thus indicating special care on using groundwater from this region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improper use of pesticides can lead to significant environmental impacts such as, contamination of environmental compartments, being the aquatic compartments the most vulnerable. In this context, the spatialization of pesticides concentrations estimative in groundwater provides important insights for decision making in managing and monitoring pesticides use. This study aimed to spatialize estimatives of groundwater contamination by Tebuthiuron, from different irrigation depths in the Rio Pardo basin, Pardinho-SP, Brazil. The simulations were performed using the ARAquá computer system, considering 0mm, 200 mm and 400 mm annual irrigation depths. Geostatistical techniques were used to obtain the spatial distribution of the simulated estimative. Tebuthiuron maps estimating concentration in groundwater were obtained by Kriging interpolation method, and indicated the areas with high potential for groundwater contamination. Considering all the simulations, it was concluded that there was no risk of groundwater contamination by Tebuthiuron in the study area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agriculture is an activity in which there is the possibility of using lower quality water and reuse appears as an alternative for irrigation. However, the negative environmental effects of reuse must be understood. The objective of the present work was to verify the potential of groundwater contamination by nitrogen duo to drip irrigation with effluent from domestic wastewater treatment. Three crop cycles of lettuce cv. Raider were conducted, the first between October and November 2009, the second in April and May 2010 and the third one in June and July 2010. The use of effluents was compared with potable water at accumulated water depths of 98.8 mm for the first, 98.4 mm for the second and 119 mm for the third cycle. Soil percolate concentrations of nitrate, nitrite and ammonia were studied at 0.25 m and 0.50 m depths in a completely randomized design. Percolate concentrations of nitrite and ammonia in soil irrigated with effluents showed no groundwater contamination risk. Nitrate however, caused concern, albeit with similar concentrations for both effluent and potable water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wastewater discharge produces impacts on receiving water bodies. Nutrients as P produce implications on lentic systems because they accelerate the eutrophication processes. Several technologies for P removal from the wastewater have been used: physic chemical treatment systems with important effects by coagulant products addition; biological processes based on anaerobic and aerobic conditions with great implications on the required volume; natural systems as stabilization ponds and irrigation require bigger areas and post-treatment processes. The aerobic fluidized bed reactors with internal circulation (AFBRIC) are compact options with high concentrations of active biomass that have demonstrated their capacity for organic matter and N removal. For sewage from the wastewater pumping station of Ilha Solteira city and effluents of a recirculation aquaculture system (RAS) for semi-intensive tilapia farming, the reactive P and total P removal efficiency in three AFBRIC with 250 mm external tube diameter and different internal tube diameter (ITD), for two different support media at different concentrations was evaluated. The average reactive P removal efficiency for domestic wastewater to hydraulic retention time (HRT) of 3 hours and 125 mm ITD reactor varied from 25,6 to 38,4% and with 150 mm ITD reactor varied from 27,5 to 32,5%; the average total P removal for the RAS wastewater at a HRT of 0,19 hours and 100 mm ITD was of 32,7%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)