33 resultados para Zinc electroplated steel wire
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Residual stresses play an important role in the fatigue lives of structural engineering components. In the case of near surface tensile residual stresses, the initiation and propagation phases of fatigue process are accelerated; on the other hand, compressive residual stresses close to the surface may increase fatigue life. In both decorative and functional applications, chromium electroplating results in excellent wear and corrosion resistance. However, it is well known that it reduces the fatigue strength of a component. This is due to high tensile internal stresses and microcrack density. Efforts to improve hard chromium properties have increased in recent years. In this study, the effect of a nickel layer sulphamate process, as simple layer and interlayer, on fatigue strength of hard chromium electroplated AISI 4340 steel hardness - HRc 53, was analysed. The analysis was performed by rotating bending fatigue tests on AISI 4340 steel specimens with the following experimental groups: base material, hard chromium electroplated, sulphamate nickel electroplated, sulphamate nickel interlayer on hard chromium electroplated and electroless nickel interlayer on hard chromium electroplated. Results showed a decrease in fatigue strength in coated specimens and that both nickel plating interlayers were responsible for the increase in fatigue life of AISI 4340 chromium electroplated steel. The shot peening pre-treatment was efficient in reducing fatigue loss in the alternatives studied.
Resumo:
Introduction: The purpose of this study was to use photoelastic analysis to compare the system of forces generated by retraction T-loop springs made with stainless steel and titanium-molybdenum alloy (TMA) (Ormco, Glendora, Calif) with photoelastic analysis. Methods: Three photoelastic models were used to evaluate retraction T-loop springs with the same preactivations in 2 groups. In group 1, the loop was constructed with a stainless steel wire, and 2 helicoids were incorporated on top of the T-loop; in group 2, it was made with TMA and no helicoids. Results: Upon using the qualitative analysis of the fringe order in the photoelastic model, it was observed that the magnitude of force generated by the springs in group 1 was significantly higher than that in group 2. However, both had symmetry for the active and reactive units related to the system of force. Conclusions: Both springs had the same mechanical characteristics. TMA springs showed lower force levels. (Am J Orthod Dentofacial Orthop 2011;140:e123-e128)
Resumo:
The aim of this study was to evaluate the tensile strength of orthodontic wires bonded onto the enamel with cyanoacrylate ester. To obtain the specimens, 120 human premolars (extracted for orthodontic or periodontal reasons) were included in acrylic blocks of rapid polymerization with three teeth each. Four groups were formed with ten specimens each. In the specimens, a dental splint model was made with cyanoacrylate ester and round stainless steel wire. In groups I, II and III, cyanoacrylate ester was used with round steel wires, with variation in diameter: 0.014 inches; 0.016 inches and 0.018 inches, respectively. In group IV, round steel wire 0.018 inches was used with photo polymerizing resin composite with previous acid etching. The adhesive force of the materials was measured in two points under the action of the tensiometer (ETM-USA). The number of loose wires was counted along with those that remained fixed according to the different levels of force applied because of the direction of the tensile force (vertical or horizontal) and the diameter of the wire used. The data obtained were first submitted to a descriptive analysis and then submitted to a statistical analysis (Friedman's Test and Dunn's Test of Multiple Comparison - Epi-info 3.2). Within the limitations of the experimental conditions presented, the cyanoacrylate ester or 'Super Bonder (R)' maintained bonded to enamel and steel wires (0.016 and 0.018 inches) during the tensile strength tests under different levels of applied forces.
Resumo:
The purpose of this study was to evaluate histologically, in dogs, the periodontal healing of 1-walled intraosseous defects in teeth that were subjected to orthodontic movement toward the defects. The defects were surgically created bilaterally at the mesial aspects of the maxillary second premolars and distal aspects of the mandibular second premolars of 4 mongrel dogs. One week after creating the defects, an orthodontic appliance was installed, and the teeth were randomly assigned to 1 of 2 treatment groups: those in the test group received a titanium-molybdenum alloy rectangular wire spring that performed a controlled tipping root movement, and those in the control group received a passive stainless steel wire. Active orthodontic movement of the test teeth lasted 2 months and was followed by a stabilization period of another 2 months, after which the animals were killed. Throughout the study, routine daily plaque control was performed on the dogs with a topical application of a 2% chlorhexicline gel. The results showed no difference between the groups, with some regularization of the defects and periodontal regeneration limited to the apical portion of the defects. Histometric analysis showed a significant difference in bone height; on average, it was 0.53 mm smaller in the test group. It was concluded that orthodontic movement does not interfere with the healing of 1-walled intraosseous defects, with the exception of the linear extent of new bone apposition.
Resumo:
O trauma do seio frontal não é raro, correspondendo a 8% das fraturas faciais. Pode afetar a lâmina anterior e/ou posterior, com ou sem envolvimento do ducto nasofrontal. Tem alto potencial para complicações e seu manejo ainda é controvertido em algumas situações. OBJETIVO: Apresentar a epidemiologia, o diagnóstico e tratamento clínico e cirúrgico de 24 pacientes com fratura do seio frontal. MATERIAL E MÉTODOS: Estudo retrospectivo, não randomizado, de 24 pacientes com fratura de seio frontal operados no Hospital das Clínicas da Faculdade de Medicina de Botucatu, São Paulo, Brasil. RESULTADOS: Dos 24 pacientes, 16 tinham fraturas da lâmina externa e 8, da lâmina interna e externa. em 2 casos havia lesão do ducto nasofrontal. Vinte (83,4%) pacientes tiveram fraturas faciais associadas e em 13 (54,2%) foram observadas complicações intracranianas. A incisão em asa de borboleta, abaixo da sobrancelha, foi empregada na maioria dos casos cirúrgicos com bom resultado estético. Fixação dos fragmentos ósseos com diferentes materiais (fio de aço, mononylon, miniplacas de titânio) e, se necessário, reconstrução da tábua anterior com material aloplástico ou osso parietal. CONCLUSÃO: A causa principal das fraturas do seio frontal é acidente com veículos. O tratamento depende de sua complexidade, pois comumente há lesões cranioencefálicas associadas. As técnicas cirúrgicas utilizadas são as incisões, retalho bicoronal ou na sobrancelha, infra-orbital (em asa de borboleta), associadas à cirurgia endoscópica em casos de infecção fístula liquórica e complicações orbitárias.
Resumo:
This study analyzed mineral trioxide aggregate (MTA) as a root canal filling material for the immediate reimplantation of monkey teeth. Four adult capuchin monkeys Cebus apella were used, which had their maxillary and mandibular lateral incisors on both sides extracted and reimplanted after 15 min. During the extra-alveolar period, the teeth were kept in saline solution and after reimplantation retention was performed with a stainless steel wire and composite resin for 14 days. After 7 days, the reimplanted teeth were submitted to endodontic treatment with biomechanics up to file n. 30 and irrigation with a saturated solution of calcium hydroxide [Ca(OH)(2)], and then divided into two study groups: group I - root canal filled with a Ca(OH)(2) paste, and group II - root canal filled with MTA. Radiographic follow up was performed at 30, 60 and 90 days postoperatively, and after 180 days the animals were killed and specimens were processed for histomorphological analysis. The results revealed that most specimens of both groups presented organized periodontal ligament with no inflammation. The resorptions observed were surface resorptions and were repaired by cementum. Both MTA and Ca(OH)(2) were good root canal filling materials for immediately reimplanted teeth, providing good repair and also allowing biological sealing of some lateral canals. There was no significant difference between the study groups (alpha = 29.60%).
Resumo:
There occurs a biological response of the tissues of dental support, in answer to the external physiological forces and those realized during clinical treatments with orthodontical purposes. These forces differ from the first ones because they are continuous and time dependent. A great dental mobility is related to the degree of tissue organization of the periodontium system and the orthodontical movement must utilize this exceptional capacity of renewal and adaptation of the periodontium structures adequately. Therefore, through histological means a search was made to evaluate the succession of alterations of the periodontium system after the application of an orthodontical force on the molars of young rats and to interpret the standards of horizontal mobility and their consequences on the periodontium structures, biologically. An orthodontic force was applied on young rats utilizing steel wire placed in a ring form on a contact point between the first and second lower molars. The animals were sacrificed after 30 minutes, 1, 2, 6, 12, 24, 48, 72, 96 and 168 hours after the placement of the metal ring. After technical preparation, the microscopic slides were examined and the results were compared. In all the sections there was evidence of an intense metabolic activity. A gradual evolution of modification on the phenomenons had occurred.
Resumo:
Objective: To analyze the effects of thermal cycling on the microtensile shear bond strength of a self-etching and a conventional pit and fissure sealants to dental enamel. Material and Method: Twenty-four healthy human molars extracted for orthodontic reasons, were sectioned in the mesio-distal direction and divided into two groups (n=24) according to the sealant to be applied: GI - conventional sealant Climpro (3M/ESPE) and GII - self-etching sealant Enamel Loc (Premier Dental). The sealants were applied on flattened enamel in matrixes 1 mm in diameter, in accordance with the manufacturers' recommendations. The specimens were stored in distilled water at 37°C for 24 hours. After this, half the samples of both groups were submitted to 500 thermal cycles in 30s baths at temperatures between 5 and 55°C. Forty-eight hours after the samples were made, the microtensile shear test was performed in an Instron 4411 test machine, with a stainless steel wire with a cylindrical cross section of 0.2mm in diameter at a constant speed of 0.5mm/s. The bond strength values were submitted to ANOVA for 2 factors and the fracture patterns were examined under an optical microscope at 65X magnification. Results: Thermal cycling did not influence the bond strength of the two sealants. The conventional sealant Climpro presented a statistically higher microtensile shear bond strength (11.72MPa, 11.34MPa with and without cycling, respectively) than the self-etching sealant Enamel Loc (5.92MPa, 5.02MPa with and without cycling, respectively). Fracture pattern analysis showed the occurrence of 100% of adhesive failures for Enamel Loc, while the conventional sealant Climpro presented 95% of adhesive failures and 5% of mixed failures. Conclusion: The conventional sealant presented higher microtensile shear bond strength to dental enamel in comparison with the self-etching sealant. Thermal cycling did not affect the bond strength of the sealants used in this study. © 2011 Nova Science Publishers, Inc.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose of this article is to demonstrate an application of the design of block experiments via analysis and multiple linear regression in the investigation of a steel thermal treatment process with multiple responses. The study aimed to design statistical models to predict the mechanical properties in SAE 9254 draw steel wires, with diameters of 2.00 mm and 6.50 mm, after quench hardening and tempering. For this purpose, process input variables (wire diameter, processing speed, tempering temperature and polymer concentration) were investigated regarding their influence on the material tensile strength, yield point and hardness. The results revealed that the mechanical properties of the steel wire are significantly influenced by the selected variables, and analysis of variance (ANOVA) was employed to validate the design of the statistical models. Multiple linear regression allowed for an appropriate representation of the process, and graphical analysis was found to be very useful in displaying the behavior of the multiple responses.
Resumo:
The aim of this study was to evaluate the biocampatibility of the commercial nylon band used as bone cerclage, comparing with traditional metal cerclage wires. Twenty one rabbits and fifteen rats, healthy and without orthopedics problems were used. A commercial nylon band and a surgical stainless steel wire 0 were used in right (SN) and left (SA) rabbits's hindlimb, respectively. Otherwise, on rats SN was on the left hindlimb, and SA on the right hindlimb. Both experimental species were divided into three groups according to the end of the evaluation period. Clinical, radiographic, macroscopic and histologically evaluation were performed at 30, 60 and 150 days postoperatively. All the animals showed normal limb function differences between groups were not observed at clinical and macroscopic evaluation. On both species, radiographic changes were slightly higher on SN. Histological differences were not observed in both species. Nylon bands do not cause foreign body reaction and other histological changes in rabbits and rats.
Resumo:
O tratamento endodôntico é uma etapa importante do protocolo de atendimento do reimplante dentário e tem uma relação direta com o aparecimento das reabsorções radiculares, maior causa de perda dos dentes reimplantados. O objetivo do trabalho foi analisar o processo de reparo no reimplante tardio de dente de macaco, utilizando o hidróxido de cálcio (Ca(OH)2) e o MTA como materiais obturadores de canal. Cinco macacos Cebus apella adultos tiveram seus incisivos laterais superiores e inferiores, direito e esquerdo, extraídos e deixados em meio ambiente por 60 minutos. Decorrido esse período, foi realizado o preparo biomecânico dos canais e os dentes foram divididos em dois grupos experimentais: grupo I - canal preenchido com pasta de Ca(OH)2 e grupo II - canal preenchido com MTA (Angelus®). Após o selamento da abertura coronária com ionômero de vidro, o ligamento periodontal foi removido e os dentes imersos em solução de fluoreto de sódio 2%, pH 5,5, por 10 minutos. Em seguida, os alvéolos foram irrigados com soro fisiológico e os dentes reimplantados e contidos por 30 dias com fio de aço e resina composta. A eutanásia dos animais foi realizada 60 dias após o reimplante. Os espécimes de ambos os grupos apresentaram reabsorção por substituição e pontos de anquilose ao longo dos três terços radiculares e ausência de reabsorção inflamatória. Não houve diferença significante entre os dois grupos com relação à reabsorção por substituição, porém a quantidade de anquilose foi significativamente maior no grupo do Ca(OH)2. Baseado nesses resultados conclui-se que o MTA pode ser uma opção clínica viável para a obturação de dentes tardiamente reimplantados que necessitam de um longo período de curativo com hidróxido de cálcio.