20 resultados para WM

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nove vacas Holandesas lactantes com 526 ± 5 kg de peso corporal (cinco predominantemente pretas e quatro predominantemente brancas), criadas em região tropical e manejadas em pastagens, foram observadas com os objetivos de determinar simultaneamente as taxas de evaporação cutânea e respiratória em ambiente tropical e desenvolver modelos de predição. Para a medição da perda de calor latente pela superfície corporal, utilizou-se uma cápsula ventilada e, para a perda por respiração, utilizou-se uma máscara facial. Os resultados mostraram que as vacas que tinham maior peso corporal (classe 2 e 3) apresentaram maiores taxas evaporativas. Quando a temperatura do ar aumentou de 10 para 36ºC e a umidade relativa do ar caiu de 90 para 30%, a eliminação de calor por evaporação respiratória aumentou de aproximadamente 5 para 57 W m-2 e a evaporação na superfície corporal passou de 30 para 350 W m-2. Esses resultados confirmam que a eliminação de calor latente é o principal mecanismo de perda de energia térmica sob altas temperaturas (>30ºC); a evaporação cutânea é a maior via e corresponde a aproximadamente 85% da perda total de calor, enquanto o restante é eliminado pelo sistema respiratório. O modelo para predizer o fluxo de perda de calor latente baseado em variáveis fisiológicas e ambientais pode ser utilizado para estimar a contribuição da evaporação na termorregulação, enquanto o modelo baseado somente na temperatura do ar deve ser usado apenas para a simples caracterização do processo evaporativo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se com este trabalho determinar as curvas de crescimento de aves de postura das linhagens semipesadas Hy Line Marrom (HLM) e Hisex Marrom (HSM) e leves Hy Line W36 (HLW36) e Hisex Branca (HSB). Foram utilizadas 300 aves de cada linhagem, distribuídas em um delineamento experimental inteiramente casualizado, com quatro repetições de 75 aves por tratamento. Semanalmente, foram avaliados o peso vivo (PV), o peso de pena (PP) e a composição corporal de proteína, gordura, cinzas e água. As curvas de crescimento foram determinadas aplicando-se os dados na função de Gompertz. As aves semipesadas foram mais tardias para PV que as leves, com taxas de crescimento corporal e pesos à maturidade (PM) maiores. Aves da linhagem HLW36 foram 64,23 g mais leves à maturidade que as HSB. As respostas obtidas para o crescimento das penas e deposição protéica foram semelhantes, todavia, os PM foram maiores para as aves marrons que para as brancas. No entanto, para estes componentes, as Hy Line tiveram maiores deposições que as Hisex. A taxa de peso de pena à maturidade foi menor na linhagem HLW36, tornando-a três dias mais tardia em comparação à HSB. A menor deposição protéica no final do período de crescimento da HSM possibilitou o desvio da energia ingerida para deposição de gordura, resultando em PM superestimado em relação às aves HLM. As aves da linhagem Hy Line foram mais tardias na composição de cinzas, apresentando PM superiores ao das aves Hisex. Entre as variáveis estudadas, os PM foram sempre maiores nas aves Hy Line, no entanto, a deposição de água corporal nas aves Hisex foi maior, assim como as taxas máximas à maturidade foram mais tardias, o que justifica a semelhança no ganho de peso entre as diferentes linhagens, visto que os demais componentes estudados foram maiores para as Hy Line.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho foi realizado para avaliar o crescimento e desempenho de duas linhagens de aves pescoço pelado. Foram utilizadas 400 aves, distribuídas em um delineamento inteiramente casualizado, os tratamentos consistiram de um esquema fatorial 2 x 2 (linhagens x sexo), com cinco repetições de 20 aves cada. Foram utilizadas aves Pescoço Pelado das linhagens Sasso e ISA Label. As aves receberam rações formuladas à base de milho e de farelo de soja para atender às exigências nutricionais. Foi determinado o ganho de peso (GP), o consumo de ração (CR) e a conversão alimentar (CA) aos 28, 56 e 84 dias de idade e o rendimento de carcaça e de partes aos 84 dias de idade. Não foi observada interação entre sexo e linhagem (P>0,05) para nenhuma das variáveis de desempenho analisadas. Para CR e GP houve diferenças significativas (P<0,05) entre as linhagens e entre os sexos nos três períodos. As aves da linhagem Sasso apresentaram desempenho superior à ISA Label. em relação aos parâmetros descritos da equação de Gompertz, as aves da linhagem Sasso apresentaram maior peso à maturidade (Pm) e tempo em que a taxa de crescimento é máxima (t*) e menor taxa de maturidade (b), indicando que as aves da linhagem ISA Label foram mais precoces para atingir a idade de máximo crescimento. As fêmeas demonstraram melhor aptidão para rendimento de peito e os machos para o rendimento de coxa e de sobra-coxa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foram estudados os efeitos da temperatura cutânea (Ts) sobre a taxa de termólise por evaporação cutânea (Es) de vacas Holandesas cronicamente expostas ao sol, considerando a pigmentação do pelame. Dezesseis vacas puras de origem foram medidas quanto à evaporação e à temperatura cutâneas às 13 h, após 6 horas de exposição ao sol, no mesmo local (flanco, pescoço e glúteo) e considerando separadamente as malhas negras e as brancas. A evaporação cutânea foi medida por meio de cápsula ventilada. Nas áreas negras a taxa de sudação (138,9 ± 8,5 g.m-2.h-1), a taxa de termólise por evaporação cutânea (93,3 ± 5,7 W.m-2) e a temperatura da superfície cutânea (33,1 ± 0,2°C) foram maiores que nas áreas brancas (109,5 ± 9,7 g.m-2.h-1, 73,6 ± 6,5 W.m-2 e 32,6 ± 0,2°C, respectivamente). Há uma relação exponencial entre evaporação e temperatura cutâneas, que pode ser representada pela equação Es = 31,5+3,67 exp{(Ts-27,9)/2,19115}, com coeficiente de determinação r²=0,68. A taxa de termólise por evaporação cutânea permanece quase constante (cerca de 48 W.m-2) até que a temperatura cutânea atinge aproximadamente 31°C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Walker's 256 carcinoma changes its behaviour as a consequence of various factors. In this paper the authors compare the evolution of 2 lines of the tumor: WM 16 (muscular) and Christ Hospital (ascitic) both inoculated intramuscularly. Animals receiving line WM 16 had a severe rapidly progressive evolution dying around day 14 after inoculation with diffuse metastases to lymph nodes (65% of animals), kidneys (53%), spleen (50%), lungs (46.5%), liver (45%), bone marrow (44.8%), in 56% of the animals there were circulating tumoral cells. Animals receiving the Christ Hospital line survived up to 40 days, metastases were limited to lungs (48.7%) and lymph nodes (31.7%) and only in 2 of 45 animals circulating tumoral cells were observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The photo-Fenton process using potassium ferrioxalate as a mediator was investigated for the photodegradation of dichloracetic acid (DCA) and 2,4-dichlorophenol (DCP) in aqueous medium using solar light as source of irradiation. The influence of the solution depth, the light intensity and the effect of stirring the solution during irradiation process were evaluated using DCA as a model compound. A negligible influence of stirring the solution was observed when the concentration of ferrioxalate (FeOx) was 0.8 mM and solution depth was 4.5 or 14 cm. The optimum FeOx concentration determined for solution depths between 4.5 and 14 cm was 0.8 mM considering total organic carbon (TOC) removal during DCA irradiation. The high efficiency of the photo-Fenton process was demonstrated on summer days, when only 10 min of exposition (around noon) were sufficient to completely destroy the organic carbon of a 1.0 mM DCA solution in the presence of 0.8 mM FeOx and 6.0 mM H2O2 using a solution depth of 4.5 cm. It was observed that the photodegradation efficiency increases linearly with the solar light intensity up to values around 15 Wm-2 but this linear relationship does not hold above this value showing a square root dependence. The photodegradation of a solution of DCP/FeOx showed a lower TOC removal rate than that observed for DCA/FeOx, achieving ∼90% after 35 min irradiation under 19 Wm-2, while under this light intensity, the same TOC removal of DCA/FeOx was achieved in only 10 min irradiation. © 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Genetic correlations of selection indices and the traits considered in these indices with mature weight (MW) of Nelore females and correlated responses were estimated to determine whether current selection practices will result in an undesired correlated response in MW. Genetic trends for weaning and yearling indices and MW were also estimated. Data from 612,244 Nelore animals born between 1984 and 2010, belonging to different beef cattle evaluation programs from Brazil and Paraguay, were used. The following traits were studied: weaning conformation (WC), weaning precocity (WP), weaning muscling (WM), yearling conformation (YC), yearling precocity (YP), yearling muscling (YM), weaning and yearling indices, BW gain from birth to weaning (BWG), postweaning BW gain (PWG), scrotal circumference (SC), and MW. The variance and covariance components were estimated by Bayesian inference in a multitrait analysis, including all traits in the same analysis, using a nonlinear (threshold) animal model for visual scores and a linear animal model for the other traits. The mean direct heritabilities were 0.21 ± 0.007 (WC), 0.22 ± 0.007 (WP), 0.20 ± 0.007 (WM), 0.43 ± 0.005 (YC), 0.40 ± 0.005 (YP), 0.40 ± 0.005 (YM), 0.17 ± 0.003 (BWG), 0.21 ± 0.004 (PWG), 0.32 ± 0.001 (SC), and 0.44 ± 0.018 (MW). The genetic correlations between MW and weaning and yearling indices were positive and of medium magnitude (0.30 ± 0.01 and 0.31 ± 0.01, respectively). The genetic changes in weaning index, yearling index, and MW, expressed as units of genetic SD per year, were 0.26, 0.27, and 0.01, respectively. The genetic trend for MW was nonsignificant, suggesting no negative correlated response. The selection practice based on the use of sires with high final index giving preference for those better ranked for yearling precocity and muscling than for conformation generates only a minimal correlated response in MW. © 2013 American Society of Animal Science. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article, the authors aim to present a critical review of recent MRI studies addressing white matter (WM) abnormalities in Alzheimer's disease (AD) and mild cognitive impairment (MCI), by searching PubMed and reviewing MRI studies evaluating subjects with AD or MCI using WM volumetric methods, diffusion tensor imaging and assessment of WM hyperintensities. Studies have found that, compared with healthy controls, AD and MCI samples display WM volumetric reductions and diffusion tensor imaging findings suggestive of reduced WM integrity. These changes affect complex networks relevant to episodic memory and other cognitive processes, including fiber connections that directly link medial temporal structures and the corpus callosum. Abnormalities in cortico-cortical and cortico-subcortical WM interconnections are associated with an increased risk of progression from MCI to dementia. It can be concluded that WM abnormalities are detectable in early stages of AD and MCI. Degeneration of WM networks causes disconnection among neural cells and the degree of such changes is related to cognitive decline. © 2013 2013 Expert Reviews Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Environmental monitoring of aquatic systems is an important tool to support policy makers and environmental managers' decisions. Long-term, continuous collection of environmental data is fundamental to the understanding of an aquatic system. This paper aims to present the integrated system for environmental monitoring (SIMA), a long-term temporal series system with a web-based archive for limnological and meteorological data. The following environmental parameters are measured by SIMA: chlorophyll-a (µgL-1), water surface temperature (ºC), water column temperature by a thermistor string (ºC), turbidity (NTU), pH, dissolved oxygen concentration (mg L-1), electric conductivity (µS cm-1), wind speed (ms-1) and direction (º), relative humidity (%), shortwave radiation (Wm-2) and barometric pressure (hPa). The data were collected in a preprogrammed time interval (1 hour) and were transmitted by satellite in quasi-real time for any user within 2500 km of the acquisition point. So far, 11 hydroelectric reservoirs are being monitored with the SIMA buoy. Basic statistics (mean and standard deviation) and an example of the temporal series of some parameters were displayed at a database with web access. However, sensor and satellite problems occurred due to the high data acquisition frequency. Sensors problems occurred due to the environmental characteristics of each aquatic system. Water quality sensors rapidly degrade in acidic waters, rendering the collected data invalid. Data is also rendered invalid when sensors become infested with periphyton. Problems occur with the satellites' reception of system data when satellites pass over the buoy antenna. However, the data transfer at some inland locations was not completed due to the satellite constellation position. Nevertheless, the integrated system of water quality and meteorological parameters is an important tool in understanding the aquatic system dynamic. It can also be used to create hydrodynamics models of the aquatic system to allow for the study of meteorological implications to the water body.