41 resultados para Void

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative Ureaplasma urealyticum culture was performed on clean first-void and midstream urine to evaluate the presence of these mollicutes in the urinary tract. The results, expressed as color changing units (CCU), showed that 14 (63%) of the 22 Ureaplasma urealyticum positive patients yielded counts equal to or higher that 10(7) CCU/mL for both the initial and the middle urine specimens. No abnormal chemical or microscopic findings (protein content, leukocyte numbers) were observed. The occurrence of U. urealyticum in midstream urine samples, even when numbers are considered, may be no more than a guide to the presence of ureaplasmas in the urinary tract.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A compactação do solo tem sido assunto de intensivas pesquisas nos últimos anos; no entanto, os mecanismos que implicam o processo de compactação dos solos agrícolas, ainda permanecem pouco conhecidos. A contribuição do tamanho de agregados do solo, bem como o efeito do teor de água e da pressão normal aplicada na compactação e pressão de pré-compactação do solo, foi investigada em um Nitossolo Vermelho eutrófico. Amostras de solo deformado, constituídas por agregados menores que 2,5 mm e de 9,3 a 19,4 mm, foram submetidas a ensaio de compressão uniaxial drenado. O índice de vazios e a pressão de pré-compactação foram avaliados. Os resultados obtidos mostram que o tamanho de agregados teve efeito no processo de compactação do solo. A mudança da compactação do solo pode ser prevista em função do estado inicial do solo, da pressão aplicada e do teor de água.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dois condicionadores químicos, a carboximetilcelulose, nas dosagens de 0,1% e 0,25% em relação ao peso do solo seco, e o silicato de sódio, de relação sílica-álcali igual a 3,2, a 0,6% e 1,2% em peso, foram pesquisados quanto aos seus efeitos sobre os índices físicos dos solos argiloso e barro arenoso empregados neste trabalho. Os dados obtidos foram estatisticamente analisados e os resultados permitiram que se chegassem a algumas conclusões. O tratamento 0,25% de carboximetilcelulose diminuiu o peso específico aparente seco e aumentou, consequentemente, o índice de vazios e porosidade dos solos estudados. O efeito dos tratamentos 1,2% de silicato de sódio e 0,1% de carboximetilcelulose sobre o peso específico aparente seco dos solos argilosos e barro arenoso, respectivamente, foi semelhante ao do tratamento 0,25% de carboximetilcelulose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudos foram conduzidos com o objetivo de avaliar os depósitos de gotas pulverizadas através de dois tipos de pontas sobre as faces adaxial e abaxial de folhas de Eichhornia crassipes dispostas em diferentes ângulos. No primeiro estudo, os tratamentos foram dispostos no esquema fatorial 2x4x7: dois tipos de pontas (TX12 e XR11002VS), quatro ângulos verticais (0º, 30º, 60º e 90º) e sete ângulos horizontais (0º, 15º, 30º, 45º, 60º, 75º e 90º). No ângulo vertical de 90º a lâmina foliar foi posicionada paralelamente ao sentido de deslocamento do jato de pulverização; e no ângulo horizontal de 90º a folha foi posicionada perpendicularmente ao plano do solo. Como traçadores, foram utilizadas soluções de 1.000 ppm do corante Azul FDC-1 e 3.500 ppm do corante Amarelo Tartrasina para as pontas tipo leque e cone, respectivamente. No segundo estudo, os tratamentos foram dispostos no esquema fatorial 2x2x3: dois tipos de pontas (TX12 e XR11002VS), dois tipos de calda (com e sem Aterbane BR a 0,5%) e três ângulos horizontais (0º, 45º e 90º). Adotou-se o ângulo vertical de 90º como padrão para todos os tratamentos. Soluções de 1.000 ppm do corante Azul FDC-1 e 3.500 ppm do corante Amarelo Tartrasina foram utilizadas como traçadores para a calda com e sem surfatante, respectivamente. Os resultados do primeiro estudo revelaram que os depósitos observados em toda a folha e na face adaxial das lâminas foliares de aguapé diminuíram à medida que se aumentou a angulação vertical, independentemente da ponta utilizada. Os menores depósitos sempre estiveram relacionados ao ângulo vertical de 90º, independentemente do ângulo horizontal utilizado. Não foi detectado nenhum depósito na face abaxial das folhas de aguapé em todas as combinações dos fatores estudados. No segundo estudo também foram observados os mesmos decréscimos no volume de calda depositado em toda a folha e na face adaxial à medida que se aumentou a angulação vertical das lâminas foliares. As duas pontas proporcionaram depósitos nulos na face abaxial quando o surfatante não foi utilizado; entretanto, a adição do surfatante à calda incrementou significativamente os depósitos nesta face da folha do aguapé.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A major difficulty to achieve maximum weight savings in the manufacture of composite structural components, is the tendency of these materials have the formation of voids and cracks in the interior and surface components. In aeronautical applications, controlling the volume fraction of fibers, resins and empty the components of composite is very hard. In this work, composites of epoxy matrix RTM6 reinforced with NCF (non crimp fabric carbon) processed by resin transfer molding (RTM) were characterized for porosity (P-ap) and density (rho(ad)). We used a method based on Archimedes' principle (ASTM C830) and the technique of helium pycnometer. The porosity values were compared with those determined by acid digestion (ASTM D3171). The mechanical properties of processed composites was evaluated by testing on the performing flexural and the results were correlated with the porosity value. All techniques tested to determine void content are satisfactory. The differents results can be justified for heterogeneous void distribution on laminate and differences among techniques characteristics. (C) 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of ICM11

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A procedure for calculation of refrigerant mass flow rate is implemented in the distributed numerical model to simulate the flow in finned-tube coil dry-expansion evaporators, usually found in refrigeration and air-conditioning systems. Two-phase refrigerant flow inside the tubes is assumed to be one-dimensional, unsteady, and homogeneous. In themodel the effects of refrigerant pressure drop and the moisture condensation from the air flowing over the external surface of the tubes are considered. The results obtained are the distributions of refrigerant velocity, temperature and void fraction, tube-wall temperature, air temperature, and absolute humidity. The finite volume method is used to discretize the governing equations. Additionally, given the operation conditions and the geometric parameters, the model allows the calculation of the refrigerant mass flow rate. The value of mass flow rate is computed using the process of parameter estimation with the minimization method of Levenberg-Marquardt minimization. In order to validate the developed model, the obtained results using HFC-134a as a refrigerant are compared with available data from the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To assess pelvic floor muscle (PFM) strength in women with stress urinary incontinence (SUI) and urge urinary incontinence (UUI).Materials and Methods: 51 women were prospectively divided into two groups, according to the symptoms as SUI (G1 = 22) or UUI (G2 = 29). Demographic data, such as number of pads/ 24 hours, number of micturations/ 24 hours and nocturia, delay time of urgent void (i.e., the time period for which an urgent void could be voluntarily postponed), number of parity and vaginal deliveries were obtained using a clinical questionnaire. Objective urine loss was evaluated by 60-min. Pad Test, subjective urine stream interruption test (UST) and visual survey of perineal contraction. Objective evaluations of PFM were performed in all patients (vaginal manometry).Results: Median of age, mean number of pads/ 24 hours, nocturia and warning time were significantly higher in UUI comparing to SUI group. During UST, 45.45% in G1 and 3.44%, in G2, were able to interrupt the urine stream (p < 0.001). The 60-min. Pad Test was significantly higher in G2 compared to G1 women (2.7 +/- 2.4 vs 1.5 +/- 1.9 respectively, p = 0.049). Objective evaluation of PFM strength was significantly higher in the SUI than in the UUI patients. No statistical difference was observed regarding other studied parameters.Conclusion: Pelvic floor muscle weakness was significantly higher in women with UUI when compared to SUI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AimTo describe the early healing within the void obtained after the elevation of the sinus mucosa and simultaneous implant installation without the use of any grafting material in monkeys.Material and methodsImplants were installed simultaneously with the elevation of the maxillary sinus using the lateral approach in eight monkeys without the use of grafting material. The healing after 4, 10, 20 and 30 days was evaluated in the area distal to the implants. Paraffin sections were prepared and analyzed using qualitative histological methods.ResultsThe healing process was initiated by the formation of a coagulum and followed by a provisional matrix and woven bone. Subsequently, a parallel-fiber bone replaced woven bone. The dimension of the elevated area shrank during the healing process. Sprouts of woven bone, present to a moderate extent after 4 days, were more numerous after 10 and 20 days. Newly formed bone originated from the sinus walls and septa, while there was no evidence of participation of the Schneiderian membrane in this process. After 30 days, the window access appeared to be closed by a layer of newly formed trabecular bone.ConclusionsThe coagulum that filled the void distal to the implant after simultaneous elevation of the sinus floor gave rise to newly formed bone. However, the void occupied by the coagulum shrank substantially. The Schneiderian membrane did not provide a basis for new bone formation in the early phase of healing.To cite this article:Scala A, Botticelli D, Rangel IG Jr, de Oliveira JA, Okamoto R, Lang NP. Early healing after elevation of the maxillary sinus floor applying a lateral access: a histological study in monkeys.Clin. Oral Impl. Res. 21, 2010; 1320-1326.doi: 10.1111/j.1600-0501.2009.01964.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To describe the early healing processes around the implants installed after elevation of the sinus mucosa applying the lateral access technique without the use of grafting material.Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane by the lateral approach in eight monkeys, implants were installed without the use of grafting material. The healing of the tissue around the implants was evaluated after 4, 10, 20 and 30 days. Ground sections were prepared and analyzed histologically.Results: After 4 days of healing, the formation of coagulum and provisional matrix was documented within the elevated area. At 10-day interval, sprouts of woven bone were in continuity with the parent bone, and partly in contact with the implant surface at the base of the augmented area. While bone-to-implant contact increased after 20 and 30 days, the area underneath the Schneiderian membrane appeared reduced in volume and condensed toward the apex of the implants. The sinus mucosa was to some extent collapsed onto the implant surface and on the newly formed bone.Conclusions: The void initially occupied by the coagulum after sinus membrane elevation shrank substantially during the observation period. A lack of influence of the Schneiderian membrane in bone formation apical to implants was documented in the early phase of healing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the effect of a space-maintaining device fixed to the lateral wall of the maxillary sinus after the elevation of the sinus mucosa on bone filling of the sinus cavity. Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane accomplished through lateral antrostomy in four monkeys, a titanium device was affixed to the lateral sinus wall protruding into the sinus cavity to maintain the mucosa elevated without the use of grafting material. The healing of the tissue around the implants was evaluated after 3 and 6 months. Ground sections were prepared and analyzed histologically. Results: The void under the elevated sinus membrane, originally filled with the blood clot, was reduced after 3 as well as after 6 months of healing of about 56% and 40.5%, respectively. In seven out of eight cases, the devices had perforated the sinus mucosa. The formation of mineralized bone and bone marrow amounted to about 42% and 69% after 3 and 6 months, respectively. The connective tissue represented about 53% and 23% of the newly formed tissue after 3 and 6 months, respectively. Conclusions: New bone formation was found below the devices. However, shrinkage of the newly formed tissue was observed both after 3 and 6 months of healing. Hence, the space-maintaining function of the devices used in the present study has to be questioned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Air flow through packed beds was analyzed experimentally under conditions ranging from those that reinforce the effect of the wall on the void fraction to those that minimize it. The packing was spherical particles, with a tube-to-particle diameter ratio (D/dp) between 3 and 60. Air flow rates were maintained between 1.3 and 4.44 m3/min, and gas velocity was measured with a Pitot tube positioned above the bed exit. Measurements were made at various radial and angular coordinate values, allowing the distribution of air flow across the bed to be described in detail. Comparison of the experimentally observed radial profiles with those derived from published equations revealed that at high D/dp ratios the measured and calculated velocity profiles behaved similarly. At low ratios, oscillations in the velocity profiles agreed with those in the voidage profiles, signifying that treating the porous medium as a continuum medium is questionable in these cases.