11 resultados para Visualisation de logiciels
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The use of essential oils (EOs) in functional foods containing probiotic microorganisms must consider the antimicrobial activity of these oils against beneficial bacteria such as Lactobacillus rhamnosus. This study aimed to evaluate the sensitivity of L. rhamnosus cultures treated with cinnamon EO through viable cell counts and visualisation by transmission electron microscopy. Cinnamon EO at a concentration of 0.04% had a bacteriostatic activity after 2 h of incubation. Although slight alterations were detected in the cell structure, this concentration was considered to be bactericidal, since it led to a significant reduction in cell numbers after 24 h. on the other hand, cinnamon EO at a 1.00% concentration decreased cell counts by 3 log units after 2 h incubation and no viable cell count was detected after 24 h. Transmission electron microscopy indicated that cells treated with 1.00% cinnamon EO were severely damaged and presented cell membrane disruption and cytoplasmic leakage.
Resumo:
Visualisation in the field of dentistry has nor, thus far, reached the same development as other medical fields. Potential applications of visualisation techniques in this area, however, are many, ranging from educational displays to training for delicate procedures. This paper reports on the investigation of techniques for handling three-dimensional models of teeth, aiming at investigation of dental structures. An algorithm was implemented for this purpose, which reconstructs three-dimensional teeth models from two-dimensional contour slices. Results employing various data sets are presented, including the output of VRML models for exploration.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work presents a review of recent developments in phase-stepping real-time holographic interferometry with photorefractive sillenite crystals. Quantitative results are shown in micro-rotation, micro-displacement, and micro-deformation measurements, and in wave-optics and surface analysis as well. The phase stepping was carried out in a four-frame process and the resulting phase map was unwrapped by applying a sin/cos filter. The experimental results are in good agreement with the ones obtained through other means, showing the promising potentialities of phase-stepping real-time holographic interferometry for in situ visualisation, monitoring and analysis in non-destructive testing.
Resumo:
Exploratory tasks supported by visualization are usually improved by Coordinated and Multiple Views (CMV) of the data under study. Several coordination techniques have been proposed in the literature, resulting in a diversity of tools to generate mappings among the multiple views. These mappings can be highly dynamic, and their history reveals the settings employed in the multiple exploratory tasks conducted in a discovery process. Several solutions have been proposed to help users to recover the steps performed in exploratory tasks, but little support is found for registering the multiple coordination mappings employed. This paper provides a contribution in this direction, proposing a model for storing and recovering such mappings. We believe such a facility is an important feature of CMV systems, so that users can recover and rerun the coordinations performed when exploring their data. We present details of the proposed model and show some potential applications. © 2012 IEEE.
Resumo:
In this letter, we report, for the first time, the real-time in situ nucleation and growth of Ag filaments on α-Ag2 WO4 crystals driven by an accelerated electron beam from an electronic microscope under high vacuum. We employed several techniques to characterise the material in depth. By using these techniques combined with first-principles modelling based on density functional theory, a mechanism for the Ag filament formation followed by a subsequent growth process from the nano-to micro-scale was proposed. In general, we have shown that an accelerated electron beam from an electronic microscope under high vacuum enables in situ visualisation of Ag filaments with subnanometer resolution and offers great potential for addressing many fundamental issues in materials science, chemistry, physics and other fields of science.
Resumo:
The increase in the number of spatial data collected has motivated the development of geovisualisation techniques, aiming to provide an important resource to support the extraction of knowledge and decision making. One of these techniques are 3D graphs, which provides a dynamic and flexible increase of the results analysis obtained by the spatial data mining algorithms, principally when there are incidences of georeferenced objects in a same local. This work presented as an original contribution the potentialisation of visual resources in a computational environment of spatial data mining and, afterwards, the efficiency of these techniques is demonstrated with the use of a real database. The application has shown to be very interesting in interpreting obtained results, such as patterns that occurred in a same locality and to provide support for activities which could be done as from the visualisation of results. © 2013 Springer-Verlag.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
BackgroundAcute pulmonary embolism (PE) is a common cause of death, accounting for 50,000 to 200,000 deaths annually. It is the third most common cause of mortality among the cardiovascular diseases, after coronary artery disease and stroke.The advent of multi-detector computed tomographic pulmonary angiography (CTPA) has allowed better assessment of PE regarding visualisation of the peripheral pulmonary arteries, increasing its rate of diagnosis. More cases of peripheral PEs, such as isolated subsegmental PE (SSPE) and incidental PE, have thereby been identified. These two conditions are usually found in patients with few or none of the classic PE symptoms such as haemoptysis or pleuritic pain, acute dyspnoea or circulatory collapse. However, in patients with reduced cardio-pulmonary (C/P) reserve the classic PE symptoms can be found with isolated SSPEs. Incidental SSPE is found casually in asymptomatic patients, usually by diagnostic imaging performed for other reasons (for example routine CT for cancer staging in oncologic patients).Traditionally, all PEs are anticoagulated in a similar manner independent of the location, number and size of the thrombi. It has been suggested that many patients with SSPE may be treated without benefit, increasing adverse events by possible unnecessary use of anticoagulants.Patients with isolated SSPE or incidental PE may have a more benign clinical presentation compared with those with proximal PEs. However, the clinical significance in patients and their prognosis have to be studied to evaluate whether anticoagulation therapy is required.ObjectivesTo assess the effectiveness and safety of anticoagulation therapy versus no intervention in patients with isolated subsegmental pulmonary embolism (SSPE) or incidental SSPE.Search methodsThe Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched October 2013) and CENTRAL (2013, Issue 9). MEDLINE, EMBASE, LILACS and clinical trials databases were also searched (October 2013).Selection criteriaRandomised controlled trials of anticoagulation therapy versus no intervention in patients with SSPE or incidental SSPE.Data collection and analysisTwo review authors inspected all citations to ensure reliable selection. We planned for two review authors to independently extract data and to assess the methodological quality of identified trials using the criteria recommended in the Cochrane Handbook for Systematic Reviews of Interventions.Main resultsNo studies were identified that met the inclusion criteria.Authors' conclusionsThere is no randomised controlled trial evidence for the effectiveness and safety of anticoagulation therapy versus no intervention in patients with isolated subsegmental pulmonary embolism (SSPE) or incidental SSPE, and therefore we can not draw any conclusions. Well-conducted research is required before informed practice decisions can be made.
Resumo:
Dans ces dernières années, plusieurs méthodes de dimensionnement d'ouvrages de soutènement en sol renforcé ont été développés, mais la doute c’est où l'utilisation de chacun d'eux se révèle plus avantageux? Ce travail a été conçu avec l'objectif de faire une étude d’un cas historiques d'un mur en remblais renforcé avec parement végétal de 27,6 mètres de haut, dont la conception a été analysé en utilisant une méthode de calcul et des logiciels informatiques spécifiques à l’utilisation dans le domaine géotechnique. Avec cette étudesont attendus de résultats capable de présenter les principales caractéristiques de chaque méthode et où il peut le mieux être appliquée
Resumo:
Glucose biosensors based on lyophilised, crystalline and cross-linked glucose oxidase (GOx, CLEC(R)) and commercially available lyophilised GOx immobilised on top of glassy carbon electrodes modified with electrodeposited Prussian Blue are critically compared. Two procedures were carried out for preparing the biosensors: (1) deposition of one layer of adsorbed GOx dissolved in an aqueous solution followed by deposition of two layers of low molecular weight Nafion(R) dissolved in 90% ethanol, and (2) deposition of two layers of a mixture of GOx with Nafion dissolved in 90% ethanol. The performance of the biosensors was evaluated in terms of linear response range for hydrogen peroxide and glucose, detection limit, and susceptibility to some common interfering species (ascorbic acid, acetaminophen and uric acid). The operational stability of the biosensors was evaluated by applying a steady potential of -50 mV versus Ag/AgCl to the glucose biosensor and injecting standard solutions of hydrogen peroxide and glucose (50 muM and 1.0 mM, respectively, in phosphate buffer) for at least 5 h in a flow-injection system. Scanning electron microscopy was used for visualisation of the Prussian Blue redox catalyst and in the presence of the different GOx preparations on the electrode surface. (C) 2001 Elsevier B.V. B.V. All rights reserved.