25 resultados para Veneral Disease Research Laboratory

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To compare modes and sources of infection and clinical and biosafety aspects of accidental viral infections in hospital workers and research laboratory staff reported in scientific articles. Methods: PubMed, Google Scholar, ISI Web of Knowledge, Scirus, and Scielo were searched (to December 2008) for reports of accidental viral infections, written in English, Portuguese, Spanish, or German; the authors' personal file of scientific articles and references from the articles retrieved in the initial search were also used. Systematic review was carried out with inclusion criteria of presence of accidental viral infection's cases information, and exclusion criteria of absence of information about the viral etiology, and at least probable mode of infection.Results: One hundred and forty-one scientific articles were obtained, 66 of which were included in the analysis. For arboviruses, 84% of the laboratory infections had aerosol as the source; for alphaviruses alone, aerosol exposure accounted for 94% of accidental infections. of laboratory arboviral infections, 15.7% were acquired percutaneously, whereas 41.6% of hospital infections were percutaneous. For airborne viruses, 81% of the infections occurred in laboratories, with hantavirus the leading causative agent. Aerosol inhalation was implicated in 96% of lymphocytic choriomeningitis virus infections, 99% of hantavirus infections, and 50% of coxsackievirus infections, but infective droplet inhalation was the leading mode of infection for severe acute respiratory syndrome coronavirus and the mucocutaneous mode of infection was involved in the case of infection with influenza B. For blood-borne viruses, 92% of infections occurred in hospitals and 93% of these had percutaneous mode of infection, while among laboratory infections 77% were due to infective aerosol inhalation. Among blood-borne virus infections there were six cases of particular note: three cases of acute hepatitis following hepatitis C virus infection with a short period of incubation, one laboratory case of human immunodeficiency virus infection through aerosol inhalation, one case of hepatitis following hepatitis G virus infection, and one case of fulminant hepatitis with hepatitis B virus infection following exposure of the worker's conjunctiva to hepatitis B virus e antigen-negative patient saliva. of the 12 infections with viruses with preferential mucocutaneous transmission, seven occurred percutaneously, aerosol was implicated as a possible source of infection in two cases, and one atypical infection with Macacine herpesvirus 1 with fatal encephalitis as the outcome occurred through a louse bite. One outbreak of norovirus infection among hospital staff had as its probable mode of infection the ingestion of inocula spread in the environment by fomites.Conclusions: The currently accepted and practiced risk analysis of accidental viral infections based on the conventional dynamics of infection of the etiological agents is insufficient to cope with accidental viral infections in laboratories and to a lesser extent in hospitals, where unconventional modes of infection are less frequently present but still have relevant clinical and potential epidemiological consequences. Unconventional modes of infection, atypical clinical development, or extremely severe cases are frequently present together with high viral loads and high virulence of the agents manipulated in laboratories. In hospitals by contrast, the only possible association of atypical cases is with the individual resistance of the worker. Current standard precaution practices are insufficient to prevent most of the unconventional infections in hospitals analyzed in this study; it is recommended that special attention be given to flaviviruses in these settings. (C) 2011 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Syphilis is a sexually transmitted infectious disease caused by Treponema pallidum. This study reports 3 cases of syphilis and highlights the importance of identifying oral lesions for its final diagnosis. Case 1: a 48-year-old male patient presented with a bleeding ulcer in the lower lip. Overall clinical examination revealed patchy alopecia and skin target lesions. Case 2: a 61-year-old male patient presented with white spots on the lateral tongue and nodules on the dorsum of the tongue. Overall clinical examination showed erythematous target lesions on the abdomen, forearm, palms of the hand, and soles of the feet. Case 3: a 17-year-old male patient presented with an ulcerated lesion on the tongue and lymph node involvement. The following serologic tests were requested: Venereal Disease Research Laboratory, fluorescent treponemal antibody-absorption, anti-HIV-1 and anti-HIV-2, and anti-hepatitis C virus. An incisional biopsy revealed epithelial hyperplasia associated with intense and diffuse mononuclear inflammatory cell infiltration consisting mainly of plasma cells, in a perivascular and perineural distribution. The final diagnosis in the 3 patients was syphilis. Treatment consisted of 1 weekly dose of penicillin (2.4 million units, intramuscular) for 2 or 3 weeks. Immunohistochemical reactions for XIIIa, CD3, CD20, CD68, CD163, S100, CD1a, CD11c, CD83, CD138, and CD208 were performed. Clinicians should be familiarized with oral syphilis lesions in order to be able to diagnose this emerging infectious disease of variable clinical presentation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solvents represent an important group of environmental pollutants to which people are exposed daily in the workplace. The physico chemical properties of solvents may result in disturbances to cellular structures, including damage to DNA. However, the effects of mixtures of solvents are not well known. Mutations caused by environmental agents are related to cancer development and other degenerative diseases. The work in a research laboratory that uses several types of solvents is equally predisposed to these hazards. In this study, we evaluated the mutagenicity of urine from 29 subjects exposed occupationally to solvents in a chemistry research laboratory and 29 subjects without occupational exposure (controls). Urine samples were collected in polyethylene containers at the end of the work shift. For the concentration and extraction of urine samples the XAD-2 resin was used with acetone as an eluting agent. Several strains of Salmonella typhimurium (TA100, TA98, TA97a, TA1535, YG1024) should be used to assess mutagenic susceptibilities among workers exposed to organic solvents. Different doses of extract (1.5; 3.0; 6.0 and 12.0 m/ equivalents of urine per plate) were tested on S. typhimurium strains TA100 and YG 1024, with and without metabolic activation. The mutagenic activity, measured in Salmonella typhimurium YGI1024 with S9 mix, was significantly greater in urine from workers than from controls (p <= 0.05). These results indicate the relevance of using biomarkers to assess the risk of occupational exposure to organic solvents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study was conducted at the Research Laboratory of Hydraulic and Irrigation Group in the Rural Engineering Department, Technical University of Madrid (Universidad Politecnica de Madrid), Madrid, Spain. Water temperatures of 20, 30, 40 degrees C and system pressures often encountered in irrigation practices of 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190 and 200 k Pa were applied to determine the effects of different water temperatures and pressures on emitter discharge. Non-pressure compensating in-line emitter which has turbulent flow regime with a long-path (labyrinth), emitter discharge was 4 L h(-1) at system pressure of 100 kPa according to the manufacturer recommended, was used. Emitters were spaced 20 cm along the drip laterals with 16 mm diameter. Discharge equations and coefficients of variation related to temperatures of 20, 30 and 40 degrees C were obtained as q = 0.375H(0.51), q = 0.358H(0.52), q = 0.346H(0.53) and 2.68, 2.09, 3.65, respectively. Discharge of the emitter was affected by different system pressures and increased as potentially (R = 0993-0996). In general. the emitter discharge increased with increasing temperature. However, especially in the common system pressures of 90-120 k Pa, differences of obtained emitter discharges between the different water temperatures were not significant (1%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O processo ensino-pesquisa-extensão realizado com a imersão dos sujeitos em cenários reais possibilita a integração universidade-comunidade, ampliando a inserção social. O objetivo deste trabalho foi apresentar a experiência de um projeto conduzido em cinco municípios brasileiros, com a participação de docentes, pós-graduandos e acadêmicos, em parceria com prefeituras municipais e trabalhadores de saúde como cenário de ensino-pesquisa no SUS. Foram realizadas oficinas e cursos de capacitação com as equipes de saúde, gestores e conselheiros de saúde, visitas técnicas aos municípios para avaliação situacional e supervisão das atividades, avaliação da satisfação dos usuários e formação de lideranças populares. Observou-se a melhoria na organização dos serviços e estímulo ao fortalecimento do vínculo entre os usuários e prestadores de serviços. Essa experiência serviu como laboratório de aprendizagem e pesquisa, fazendo-se ciência a partir da vivência in loco da realidade do SUS e contribuindo para uma formação professional mais humanitária baseada em cenários reais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Domains where knowledge representation is too complex to be described analytically and in a deterministic way is very common in the petroleum industry, particularly in the field of exploration and production. In these domains, applications of artificial intelligence techniques are very suitable, especially in cases where the preservation of corporate and technical knowledge is important. The Laboratory for Research on Artificial Intelligence Applied to Petroleum Engineering (LIAP) at Unicamp, has, during the last 10 years, dedicated research efforts to build intelligent systems in well drilling and petroleum production fields. In the following sections, recent advances in intelligent systems, under development in the research laboratory, are described. (C) 2001 Published by Elsevier B.V. B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This experiment was carried out in the Research Laboratory on Nutrition of Aquatic Organisms, Aquaculture Center UNESP, FMVZ - Botucatu, SP, Brazil. The study aimed to evaluate the effect of raw full-fat soybean meal on feeding in fingerlings of the Nile tilapia (Oreochromis niloticus). The suitable level of consumption of raw full-fat soybean meal (RSM) was determined by means of productive performance. The experimental design was a Multivariate Profile Analyses, with four treatments (four replicates each one). Each isoproteic (26% CP) and isoenergetic (3000 Kcal ME/ kg) diet received raw full-fat soybean meal at 6.0%, 12.0% and 18.0%. A treatment without soybean meal was used as control. Forty eight fingerlings with similar size (mean Wt ± SD: 6.47 ± 0.64 g; and mean Lt ± SD: 54.94 ± 7.79 mm) at the beginning of the experiments were used. No significant difference (p>0.05%) in weight gain among the four treatments was found. However, the treatments with 12.0 and 18.0% RSM showed a reduction in the coefficient of digestibility in these treatments. This shows a deleterious effect of the raw full-fat soybean meal at these considered levels (12.0% and 18.0% RSM).