99 resultados para Vc

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the high industrial competitiveness, the rigorous laws of environmental protection, the necessary reduction of costs, the mechanical industry sees itself forced to worry more and more with the refinement of your processes and products. In this context, can be mentioned the need to eliminate the roundness errors that appear after the grinding process. This work has the objective of verifying if optimized nozzles for the application of cutting fluid in the grinding process can minimize the formation of the roundness errors and the diametrical wear of grinding wheel in the machining of the steel VC 131 with 60 HRc, when compared to the conventional nozzles. These nozzles were analyzed using two types of grinding wheels and two different cutting fluids. Was verified that the nozzle of 3mm of diameter, integral oil and the CBN grinding wheel, were the best options to obtain smaller roundness errors and the lowest diametrical wears of grinding wheels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several kinds of research in road extraction have been carried out in the last 6 years by the Photogrammetry and Computer Vision Research Group (GPF&VC - Grupo de Pesquisa em Fotogrametria e Visão Computacional). Several semi-automatic road extraction methodologies have been developed, including sequential and optimizatin techniques. The GP-F&VC has also been developing fully automatic methodologies for road extraction. This paper presents an overview of the GP-F&VC research in road extraction from digital images, along with examples of results obtained by the developed methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Estudos Linguísticos - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A percepção subjetiva de esforço (PSE) é determinada de forma não invasiva e utilizada juntamente com a resposta lactacidêmica como indicadores de intensidade durante teste incremental. em campo, especialmente na natação, há dificuldades nas coletas sanguíneas; por isso, utilizam-se protocolos alternativos para estimar o limiar anaeróbio. Assim, os objetivos do estudo foram: prescrever um teste incremental baseado na PSE (Borg 6-20) visando estimar os limiares metabólicos determinados por métodos lactacidêmicos [ajuste bi-segmentado (V LL), concentração fixa-3,5mM (V3,5mM) e distância máxima (V Dmáx)]; relacionar a PSE atribuída em cada estágio com a freqüência cardíaca (FC) e com parâmetros mecânicos de nado [freqüência (FB) e amplitude de braçada (AB)], analisar a utilização da escala 6-20 na regularidade do incremento das velocidades no teste e correlacionar os limiares metabólicos com a velocidade crítica (VC). Para isso, 12 nadadores (16,4 ± 1,3 anos) realizaram dois esforços máximos (200 e 400m); os dados foram utilizados para determinar a VC, velocidade de 400m (V400m) e a freqüência crítica de braçada (FCb); e um teste incremental com intensidade inicial baseada na PSE, respectivamente, 9, 11, 13, 15 e 17; sendo monitorados em todos os estágios a FC, lactacidêmia e os tempos de quatro ciclos de braçadas e das distâncias de 20m (parte central da piscina) e 50m. Posteriormente, foram calculadas as velocidades dos estágios, FB, AB, V LL, V3,5mM e V Dmáx. Utilizaram-se ANOVA e correlação de Pearson para análise dos resultados. Não foram encontradas diferenças entre VC, V Dmáx e V LL, porém a V3,5mM foi inferior às demais velocidades (P < 0,05). Correlações significativas (P < 0,05) foram observadas entre VC versus V400m, V Dmáx e V3,5mM; V400m versus V3,5mM e V Dmáx; V Dmáx versus V LL; e no teste incremental entre PSE versus velocidade, [Lac], FC, FB e AB (P < 0,05). Concluímos que a PSE é uma ferramenta confiável no controle da velocidade dos estágios durante teste incremental na natação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No presente estudo procedeu-se ao isolamento e caracterização da fração globulina majoritária (11 S) de grão-de-bico, var. IAC-Marrocos. A globulina majoritária extraída foi isolada por cromatografia de filtração em gel e de troca-iônica mostrando apenas uma banda de proteína na eletroforese em gel de poliacrilamida. A globulina majoritária, após passagem em coluna de Sephadex, revelou duas bandas protéicas de 55 e 52,5kDa e três bandas menores em gel de poliacrilamida dodecilsulfato de sódio. Na presença de 2-mercaptoetanol 6 polipeptídios na faixa de 18 a 42kDa foram revelados na eletroforese. A globulina isolada foi submetida à ação da tripsina e quimotripsina onde a forma nativa mostrou-se resistente à ação enzimática enquanto o aquecimento (96 e 121°C/15min) não foi suficiente para aumentar a susceptibilidade à hidrólise, significativamente. Adição de NaCl 0,3M levou a um aumento da estabilidade estrutural com menor susceptibilidade à digestão proteolítica, fato em parte perdido com o aquecimento. As hidrólises foram acompanhadas por eletroforese em gel de poliacrilamida dodecilsulfato de sódio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, doped AlGaAs/GaAs parabolic quantum wells (PQW) with different well widths (from 1000 angstrom up to 3000 angstrom) were investigated by means of photoluminescence (PL) measurements. In order to achieve the 2DEG inside the PQW Si delta doping is placed at both side of the well. We have observed that the thickness of this space layer plays a major rule on the characteristics of the 2DEG. It has to be thicker enough to prevent any diffusions of Si to the well and thin enough to allow electrons migration inside the well. From PL measurement, we have observed beside the intra well transitions, indirect transitions involving still trapped electron on the delta doping and holes inside the PQW. For the thinness sample, we have measured a well defined PL peak at low energy side of the GaAs bulk emission. With the increasing of the well thickness this peak intensity decreases and for the thickest sample it almost disappears. Our theoretical calculation indicated that carriers (electron and holes) are more placed at the center of the PQW. In this way, when the well thickness increases the distance between electrons on the delta doping and holes on the well also increases, it decreases the probability of occurrence of these indirect optical transitions. (C) 2012 Published by Elsevier B.V. Selection and/or peer-review under responsibility of Universidade Federal de Juiz de Fora, Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to explain the concept of cutting fluids reasonable usage through the fluid minimum quantity in grinding processes. on that purpose, the development of a new nozzle and an own and adequate methodology should be required in order to obtain good results and compare them to the conventional methods. The analysis of the grinding wheel/cutting fluid performance was accomplished from the following input parameters: flow rate variation by nozzle diameter changes (three diameters values: 3mm, 4mm and 5mm), besides the conventional round nozzle already within the machine. Integral oil and a synthetic emulsion were used as cutting fluids and a conventional grinding wheel was employed. The workpieces were made of steel VC 131, tempered and quenched with 60HRc. Thus, as the flow rate and the nozzle diameter changes, keeping steady fluid jet velocity (equal to cutting velocity), attempted to find the best machining conditions, with the purpose to obtain a decrease on the cutting fluid volume, taking into consideration the analysis of the process output variables such as cutting strength, cutting specific energy, grinding wheel wear and surface roughness. It was verified that the 3mm diameter optimized nozzle and the integral oil, in general, was the best combination among all proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TEMA: medidas da dinâmica respiratória são freqüentemente utilizadas na clínica fonoaudiológica, mas poucos são os dados científicos destas na população infantil. OBJETIVO: estudar a dinâmica respiratória entre crianças que respiram pelo modo nasal. MÉTODO: o estudo foi realizado com uma amostra aleatória estratificada de 106 crianças respiradoras nasais de escolas da cidade de Marília / SP, entre quatro e dez anos de ambos os sexos. Foram realizadas as medidas de capacidade vital (CV), nas posições em pé e sentada, com e sem oclusão nasal; de tempo máximo de fonação (TMF) de vogais e consoantes sustentadas, além de fala em seqüência com a contagem de números. RESULTADOS: a medida média da CV na posição em pé com e sem oclusão nasal foi 1515,56 ml e 1538,67 ml respectivamente e na posição sentada, 1524 ml e 1539,15 ml respectivamente; o TMF das vogais em segundos foi: /a/ = 8,32 , /i/ = 8,61 e /u/ 8,42; o de consoantes foi: /s/ = 6,64 e /z/ = 7,65 e o de seqüência de números foi de 7,76 segundos. Resultados: observou-se que o tempo médio destas medidas aumentou progressivamente conforme as faixas etárias. Tanto para o TMF das vogais como, para o das consoantes, houve diferença estatística significante (p < 0,05) nas idades mais distantes, ou seja, entre quatro e dez anos, quatro e nove, e quatro e oito anos. em faixas etárias consecutivas não houve diferença estatística significante nos valores de CV. Houve forte associação entre a CV e o crescimento físico da criança. CONCLUSÃO: esse estudo mostrou medidas de dinâmica respiratória em crianças que podem ser úteis no diagnóstico e terapia fonoaudiológica. Outras pesquisas deveriam ser desenvolvidas para adicionais informações sobre o assunto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)