102 resultados para Ultrasound (US)

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this work is to prospectively study the value of thoracic ultrasound (US) before pleural drainage in children with parapneumonic effusion (PPE). All children hospitalized for PPE, identified by thoracic radiography, underwent US to assess pleural loculation, echogenicity, and pleural fluid quantity. From August 2001 to July 2003, 52 children were examined. US was performed on 48 of these children, of whom 35 received chest tube drainage and 13 only received clinical treatment. US identified 38 patients with free flowing and 10 with loculated pleural fluid. About 25 of the free flowing (65.8%) and 10 (100%) of the loculated patients received chest tube drainage. Echogenicity was anechoic in 13, echoic without septations in 17 and echoic with septations in 18. Chest tube drainage was required in 6 anechoic (46.15%), 14 echoic without septations (82.35%), and 15 echoic with septations (83.33%). Quantity of fluid estimated by US varied from 20 to 860 ml. Effusion volume was higher in patients that were echoic with septations and loculated effusions. Pleural glucose and pH were lower, and LDH was higher in loculated PPE patients. In conclusion, US is an auxiliary exam for determining whether thoracic drainage is needed in parapneumonic effusion; loculated or echoic effusion should be drained, and free anechoic fluid needs further investigation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To determine whether the use of ultrasound (US) to guide embryo transfer (ET) in a population previously defined as likely to have easy transfer would change the implantation and pregnancy rates in an ICSI program.Methods: A total of 100 patients identified as likely to have easy transfer after mock transfer were divided into two groups: Group I, US-guided ET (N = 50) and Group II, ET without the aid of US (N = 50).Results: Implantation and pregnancy rates were similar (p = 0.51, p = 0.29) for Group I (19.6%,42%) and Group II (16.3%,30%), as also was the abortion rate (p = 0.55) (Group I: 1/21; Group II: 2/15).Conclusion: As long as previous mock transfers are routinely performed during a cycle preceding assisted reproduction and the clinician considers transfer to be easy, ultrasound does not benefit the process of embryo transfer.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: Ultrasound (US) therapy is an elect rot hermotherapeutic modality that uses US energy to provoke physical and chemical alterations. US therapy has been widely used in physical therapy. However in clinical practice, it is contra-indicated in cancer patients due to the possibility of exacerbating tumor growth.Methods: Sixty-eight female Sprague-Dawley rats bred in UNIFAE vivarium were studied. At 50 days of age, 7, 12-dimetylbenz(a)anthracene (7, 12-DMBA) was administered to 35 rats by gastric gavage to induce mammary cancer After 90 days the mammary glands of the rats belonging to the group with mammary cancer induction and stimulated by US were removed. Animals received either continuous or pulsed US. US waves were generated at a frequency of 1 MHz during 10 days, with an intensity dose of 0.5 W in the continuous group, and 0.9 W (duty cycle: 20%) in the pulsed group.Results: Among the rats treated with continuous US, 44.4% developed local recurrence, while among the rats treated with pulsed US, 22.2% had local tumor recurrence (p < 0.05). No evidence of distant metastases was shown in any of the rats studied.Conclusion: The use ofcontinuous and pulsed therapeutic US promoted the development of local recurrence of mammary cancer in female Sprague-Dawley rats in the postoperative period.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Ultrasound (US) has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Há evidências de que o ultrassom (US) de baixa intensidade pode acelerar a regeneração óssea. Este trabalho objetivou verificar a ação do US no defeito ósseo, criado experimentalmente em tíbias de ratos sob ausência de carga. Vinte Rattus novergicus albinus, Wistar adultos, divididos em: G1 (n=10), grupo experimental de 15 dias sem suspensão, e G2 (n=10), grupo experimental de 15 dias suspenso pela cauda, foram submetidos à osteotomia em ambas as tíbias e à aplicação do US, frequência de 1,5 MHz, ciclo de trabalho 1:4, 30 mW/cm², nas tíbias direitas por 12 sessões de 20 minutos. Após o sacrifício, as tíbias foram submetidas à análise da Densidade Mineral Óssea (DMO). Os resultados demonstraram DMO de 0,139±0,018 g/cm² para tíbia tratada; 0,131±0,009 g/cm² para tíbia controle no G1; e no G2 registrou-se 0,120±0,009 g/cm² para tíbia tratada e 0,106±0,017 g/cm² para tíbia controle. Houve diferença significante entre os grupos nos quais o G2 apresentou menor DMO, o que demonstra que a suspensão prejudica a manutenção das propriedades ósseas, e entre as tíbias tratadas e controles do G2, demonstrando que o US acelerou o processo de reparo, concluindo que a impossibilidade do estímulo mecânico causada pela não deambulação em um processo de reparo ósseo pode ser minimizada pela ação do US. No G1, a aplicação do US não teve influência significante no aumento da DMO, talvez pelo fato dos animais já terem estímulo mecânico suficiente à formação óssea.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO: O Ultrassom (US) é um dos recursos físicos amplamente utilizado e pesquisado nos tratamentos de fisioterapia. Sabe-se que diante de uma escassa literatura sobre efeitos do US em tecidos sadios, muitos profissionais fisioterapeutas acabam realizando aplicações infundadas de métodos e parâmetros. OBJETIVO: Avaliar possíveis alterações histológicas e morfométricas do tecido sadio in vivo de ratos Wistar irradiados com diferentes intensidades de US. MÉTODOS: Trinta ratos da linhagem Wistar, distribuídos aleatoriamente em cinco grupos de seis animais cada foram tratados na região dorsal do lado direito numa área de 4cm². O lado esquerdo serviu como controle. O tratamento foi feito durante quatro dias com 2 minutos de irradiação. Verificou-se a intensidade de saída com dosímetro de precisão antes das aplicações. Analisou-se a histologia e a morfometria por meio do software Image Tool. RESULTADOS: Observou-se um discreto infiltrado inflamatório e adelgaçamento das fibras da derme, principalmente dos grupos irradiados com 1.5 e 2W/cm². Notou-se também um aumento na espessura da epiderme nas amostras dos animais irradiados. Para avaliar os resultados quantitativos, utilizou-se como análise estatística ANOVA one way e o teste post hoc de Tukey. Na espessura da epiderme, obtiveram-se diferenças significativas entre grupo controle e os grupos irradiados com 1.0, 1.5 e 2.0W/cm². CONCLUSÃO: Sob ação do US nas doses maiores houve alterações na epiderme e derme, respectivamente, o aumento da espessura e proliferação com adelgaçamento das fibras colágenas, o que alerta para possíveis implicações do uso do US em estética.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this work was to verify the effect in the skin of male swines gel (G) containing hyaluronidase (H) associated or not to ultrasound (US). In different areas was applied G; G+US; G+H; G+H+US and mesotherapy (M). Skin fragment was processed in paraffin. To evidence hyaluronic acid (HA) coloration with Alcian Blue (AB) was used and coloration with Hematoxilin/Eosin for morphometry. It was observed that G+H and G+H+US did not reduce coloration for the AB nor presented significant differences for the morphometry. When H was applied mesoteraphycally coloration for the AB diminished. Then, the use of H associated or with US did not seem efficient in the HA reduction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: This study aims to evaluate the effects of soy isoflavones on breast tissue in postmenopausal women. METHODS: In this randomized, double-blind, placebo-controlled study, 80 women (aged ≥45 y and with amenorrhea >12 mo) with vasomotor symptoms were randomized to receive either 250 mg of standardized soy extract corresponding to isoflavone 100 mg/day (n = 40) or placebo (n = 40) for 10 months. Breasts were evaluated through mammographic density and breast parenchyma using ultrasound (US) at baseline and 10-month follow-up. Independent t test, analysis of variance, Mann-Whitney U test, and χ2 trend test were used in statistical analysis. RESULTS: Baseline clinical characteristics showed no significant differences between the isoflavone group and the placebo group, with mean (SD) age of 55.1 (6.0) and 56.2 (7.7) years, mean (SD) menopause duration of 6.6 (4.8) and 7.1 (4.2) years, and mean (SD) body mass index of 29.7 (5.0) and 28.5 (4.9) kg/m2, respectively (P > 0.05). The study was completed by 32 women on isoflavone and 34 women on placebo. The groups did not differ in mammographic density or breast parenchyma by US (P > 0.05). Within each group, the baseline and final moments did not differ in mammography or US parameters significantly (P > 0.05). CONCLUSIONS: The use of soy isoflavone extract for 10 months does not affect breast density, as assessed by mammography and US, in postmenopausal women. © 2013 by The North American Menopause Society.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)