58 resultados para Ultrasonics

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we developed a setup to measure the speed of sound in gases using a laser ultrasonics system. The mentioned setup is an all optical system composed by a Q-switched Nd:YAG laser to generate the sound waves, and a fiber optical microphone to detect them. The Nd:YAG provided a laser pulse of approximately 420 mJ energy and 9 ns of pulse width, at the wavelength of 1064 nm. The pulsed laser beam, focused by a positive lens, was used to generate an electrical breakdown (in the gas) which, in turn, generates an sound wave that traveled through a determined distance and reached the fiber optical microphone. The resulting signal was acquired in an oscilloscope and the time difference between the optical pulse and the arrival of the sound waves was used to calculate the speed of sound, since the distance was known. The system was initially tested to measure the speed of sound in air, at room pressure and temperature and it presented results in agreement with the theory, showing to be suitable to measure the speed of sound in gases. © 2012 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives To evaluate the presence of fungi on contact electrodes and ultrasound transducers from physiotherapy clinics.Design Quantitative study conducted at the Laboratory of Microbiology and Immunology, Faculty of Health Sciences and Technology of Piaui - NOVAFAPI, Teresina, Brazil.Setting Sample collection was performed in 10 clinics ( 20 ultrasound transducers and 20 contact electrodes).Main outcome measures Swabs were soaked with saline solution, inoculated in culture and incubated for filamentous fungi and yeast growth.Results Fourteen taxons were identified: Acremomium hyalinulum (Sacc.), Aspergillus terreus, Candida albicans, Cladosporium cladosporioides, Cladosporium elatum, Cladosporium oxysporum, Cladosporium sphaerospermum, Cladosphialophora bantiana, Curvularia clavata, Curvularia senegalensis, Fusarium oxysporum, Penicillium decumbens, Scopulariopsis candida and Sporothrix schenckii. Aspergillus terreus, Cladosporium oxysporum, Sporothrix shenckii and Candida albicans were found most often on contact electrodes, and Penicillium decumbens and Cladosporium cladosporioides were found most often on ultrasound transducers.Conclusion Fungi were found on all of the contact electrodes and ultrasound transducers. Physiotherapy professionals need to improve the disinfection procedures for this equipment. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents recent improvements in a density measurement cell with a double-element transducer that can eliminate diffraction effects. A new mechanical design combined with the use of more appropriate materials has resulted in better parallelism between interfaces, more robust assembly, and chemical resistance. A novel method of signal processing, named energy method, is introduced to obtain the reflection coefficient, reducing sensitivity to noise and improving accuracy. The measurement cell operation is verified both theoretically, using an acoustic wave propagation model, and experimentally, using homogeneous liquids with different densities. The accuracy in the density measurement is 0.2% when compared with the measurements made with a pycnometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a theoretical analysis of a density measurement cell using an unidimensional model composed by acoustic and electroacoustic transmission lines in order to simulate non-ideal effects. The model is implemented using matrix operations, and is used to design the cell considering its geometry, materials used in sensor assembly, range of liquid sample properties and signal analysis techniques. The sensor performance in non-ideal conditions is studied, considering the thicknesses of adhesive and metallization layers, and the effect of residue of liquid sample which can impregnate on the sample chamber surfaces. These layers are taken into account in the model, and their effects are compensated to reduce the error on density measurement. The results show the contribution of residue layer thickness to density error and its behavior when two signal analysis methods are used. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When the electro-optic and acousto-optic effects are combined into a single device, the resulting acousto-electro-optic (AEO) modulator shows improved flexibility to overcome some limitations of the individual modulators or their cascade combinations. By using optical interferometry, it is possible to investigate the AEO modulator behavior as a function of this applied voltage. By this way, a lithium niobate AEO modulator is positioned in one of the arms of a Mach-Zehnder interferometer and operates at 62 MHz frequency, which constitutes the intermediate frequency of the heterodyne interferometer. Operating the AEO modulator in the acousto-optic small diffraction efficiency regime, the photodetected signal amplitude and phase are analyzed, and the induced phase shift, transmission curve and linearity response are obtained. The experimental results show good agreement with that expected from the coupled-mode theory. The possibility of linear control of the optical phase shift by the external voltage, from 0 to 2 p radians, is demonstrated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os autores relatam um caso de leiomiossarcoma de retroperitônio, provavelmente originário da parede da veia cava inferior, em que foram realizados numerosos exames por imagem, com resultados contraditórios e conduta cirúrgica muito retardada. Comenta-se ainda sobre a necessidade de estabelecer-se rapidamente o diagnóstico da lesão, por meio de exames de imagem com biópsia dirigida, e a necessidade de ressecção completa da lesão, sempre que possível, ou mesmo a realização de ressecções parciais seguidas de tratamento complementar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A avaliação clínica dos membros inferiores na insuficiência venosa por si só não identifica os sistemas envolvidos ou os níveis anatômicos, sendo necessários exames complementares. Esses exames podem ser invasivos ou não-invasivos. Os invasivos, como flebografia e pressão venosa ambulatória, apesar de terem boa acurácia, trazem desconforto e complicações. Dentre os não-invasivos, destacam-se: Doppler ultra-som de ondas contínuas, fotopletismografia, pletismografia a ar e mapeamento dúplex. O Doppler ultra-som avalia a velocidade do fluxo sangüíneo de maneira indireta. A fotopletismografia avalia o tempo de reenchimento venoso, fornecendo um parâmetro objetivo de quantificação do refluxo venoso. A pletismografia a ar permite quantificar a redução ou não da capacitância, o refluxo e o desempenho da bomba muscular da panturrilha. O dúplex é considerado padrão-ouro dentre os não-invasivos, porque permite uma avaliação quantitativa e qualitativa, fornecendo informações anatômicas e funcionais, dando avaliação mais completa e detalhada dos sistemas venosos profundo e superficial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXTO: A aplicação de uma estratégia baseada em um modelo clínico associado ao mapeamento dúplex (MD) pode permitir um diagnóstico da trombose venosa profunda (TVP) mais seguro, eficaz e custo-efetivo. OBJETIVO: Testar o modelo clínico de Wells et al. associado ao MD e verificar a ocorrência de TVP nos pacientes categorizados quanto à probabilidade de apresentar a doença, e determinar se, a partir dos resultados obtidos, seria possível reduzir o número de exames seriados com o MD. MÉTODOS: Os pacientes com suspeita clínica de TVP foram categorizados quanto à apresentação de TVP em baixa, moderada e alta probabilidade (BP, MP, AP) e, em seguida, submetidos ao MD. Pacientes com MD negativo repetiram o exame em 24-48 horas e em 7 dias. Pacientes com exame positivo para TVP foram tratados. Todos os pacientes sem TVP foram convocados para reavaliação clínica em 3 meses. RESULTADOS: A ocorrência de TVP entre os 489 pacientes avaliados foi de 39,1% (191), sendo 35,6% identificados no exame inicial e 3,5% no exame seriado. Os índices de pacientes que apresentaram TVP foram de 6,1% no grupo de BP, 26,9% no grupo de MP e 79,5% no grupo de AP. No exame seriado, o percentual de TVP foi de 2,4, 7,8 e 15,1% nos grupos BP, MP e AP, respectivamente. Dos pacientes com MD negativo, 62,4% compareceram após 3 meses, e piora dos sintomas foi apresentada por apenas um paciente. Neste, o MD mostrou TVP de veia poplítea. CONCLUSÃO: Os resultados obtidos sugerem que, para os pacientes com BP para TVP e MD negativo, seria possível prescindir do exame seriado, devido à baixa ocorrência de TVP neste grupo, tornando, assim, a abordagem diagnóstica mais simples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Ultrasonic excitation (US) was applied to glass ionomer cement (GIC) during early set time to increase the advantageous properties of this material. Purpose: The aim of this in vitro study was to assess the inner porosity of GIC after US. Study design: A total of 16 specimens, for each material, were prepared from high-viscosity GIC Fuji IX GP, Ketac Molar, and Ketac Molar Easymix. Half of these specimens (n = 8) received 30 s of US during the initial cement setting. After completion of the material setting, specimens were fractured and observed by scanning electronic microscopy to quantitatively assay porosity inside the material using Image J software. Results: Statistical data analysis revealed that US reduced the porosity for all tested materials (P <= 0.05). The following reductions (expressed in percentages) were achieved: Fuji IX-from 3.9% to 2.8%; Ketac Molar Easy Mix-from 4.4% to 2.6%, and Ketac Molar-from 2.4% to 1.6%. Conclusion: Under the tested conditions, US was an effective method for porosity reduction inside the material. Microsc. Res. Tech. 74:54-57, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)