19 resultados para Tunneled central catheter
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Catheter-related bacteremia (CRB) is one of the various complications related to hemodialysis (HD). As a result of this high rate of infection, the antibiotic lock technique (ALT) has been recommended to prevent CRB. However, adverse effects of ALT such as increased emergence of strains resistant to antibiotics and increased mechanical dysfunction catheter were poorly evaluated. We prospectively evaluated the efficacy of catheter-restricted filling using an antibiotic lock solution in preventing CRB. A total of 233 HD patients requiring 325 new tunneled catheters while waiting for placement and maturation of an arteriovenous fistula or graft were enrolled in this study. Patients with a tunneled catheter were assigned to receive either an antibiotic-heparin lock solution (antibiotic group: cefazolin 10 mg/ml, gentamicin 5 mg/ml, heparin 1,000 U/ml) or a heparin lock solution (no-antibiotic group: heparin 1,000 U/ml) as a catheter lock solution during the interdialytic period. The present study aimed to assess the efficacy of ALT using cefazolin and gentamicin in reducing CRB in patients undergoing HD with tunneled central catheter and to identify its adverse effects. CRB developed in 32.4 % of patients in the no-antibiotic group and in 13.1 % of patients in the antibiotic group. CRB rates per 1,000 catheter-days were 0.57 in the antibiotic group versus 1.74 in the no-antibiotic group (p < 0.0001). Kaplan-Meier analysis also showed that mean CRB-free catheter survival was significantly higher in the antibiotic group than in the no-antibiotic group (log-rank statistic 17.62, p < 0.0001). There was statistically significant difference between the two groups in causative organisms of CRB, with predominance of negative culture in both groups, but this prevalence was higher in ALT group (57.9 vs 90.1 %, p < 0.0001), and the two groups also were different in prevalence of gram-positive bacteria as causing organisms (ALT group 21.05 vs = 0 % in control group, p < 0.0001). There was no statistically significant difference between the two groups in drug-resistant germs. There were statistically significant differences between the two groups in the catheter removal causes, with higher rate of infectious cause in control group (12.32 vs 2.22 %, p < 0.0001) and mechanical cause in ALT group (28.26 vs 37.78 %, p < 0.0001). The results suggest that ALT may be a beneficial means of reducing the CRB rate in HD patients with tunneled catheter, without association between ALT and emergence of strains resistant. However, mechanical complications were more prevalent in antibiotic group. Further studies are required to determine the optimal drug regimen, concentrations for ALT, and its adverse effects. © 2012 Springer Science+Business Media Dordrecht.
Resumo:
Despite their propensity for significant infectious and mechanical complications, tunneled central venous catheters (CVCs) have become a common means of vascular access in the world for patients requiring chronic hemodialysis for end-stage renal disease. The objective of this study was to explore if cryopreserved solutions of the thrombolytic agent alteplase could be used as an effective, safe, and economically reasonable alternative in hemodialysis patients with occluded tunneled CVC. Patients requiring chronic hemodialysis and presenting with occluded tunneled CVC received a sufficient volume of the alteplase solution to fill the occluded catheter. To make alteplase economically feasible, it was diluted to 1-mg/mL aliquots and they were stored at -20 degrees C until use. Eighty-one patients accounting for 179 attempted clearances were assessable for efficacy. One hundred forty-seven (82.1%) of the 179 catheter clearance attempts resulted in successful catheter clearance after one dose. Twenty-seven (15.1%) of all occluded CVCs were successful after two doses whereas five (2.8%) were not. No adverse events were reported. Cryopreserved 1-mg/mL aliquots of alteplase are safe and effective in the clearance of occluded CVC for hemodialysis patients.
Resumo:
Vascular access is the major risk factor for bacteremia, hospitalization, and mortality among hemodialysis (HD) patients. The type of vascular access most associated with bloodstream infection is central venous catheter (CVC). The incidence of catheter-related bacteremia ranges between 0.6 and 6.5 episodes per 1000 catheter days and increases linearly with the duration of catheter use. Given the high prevalence of CVC use and its direct association with catheter-related bacteremia, which adversely impacts morbidity and mortality rates and costs among HD patients, several prevention measures aimed at reducing the rates of CVC-related infections have been proposed and implemented. As a result, a large number of clinical trials, systematic reviews, and meta-analyses have been conducted in order to assess the effectiveness, clinical applicability, and long-term adverse effects of such measures. In the following article, prophylactic measures against CVC-related infections in HD patients and their possible advantages and limitations will be discussed, and the more recent literature on clinical experience with prophylactic antimicrobial lock therapy in HD CVCs will be reviewed.
Resumo:
Thrombosis of tunneled central venous catheters (CVC) in hemodialysis (HD) patients is common and it can lead to the elimination of vascular sites. This study aimed to evaluate the incidence of thrombotic obstruction of tunneled CVC in HD patients and the efficacy of occlusion treatment with alteplase use, and identify factors associated with thrombotic occlusion. It was a prospective cohort study performed in two centers which evaluated the diagnosis and treatment of thrombotic occlusion of CVC in HD patients for 24 consecutive months. The catheter occlusion was defined as the difficulty infusing or withdrawing fluid from their paths. Alteplase dose was infused to fill the lumen of the occluded catheter and remained for 50 min. As there was no obstruction of the catheter, the procedure was repeated. Three hundred and thirty-nine CVC in 247 patients were evaluated and followed, totalling 67 244 CVC-days. One hundred fifty-seven patients had only one CVC, 88 patients had two CVC during the study, and two patients had three CVC. The median age was 58 (47–66) years, patients were predominantly men (54%), with diabetic nephropathy as the main cause of chronic kidney disease (44%), the internal jugular vein as the main site of implantation (82%), and duration of dialysis before CVC implantation of 119 (41.5 to 585.5) days. Eight hundred and fifteen occlusion episodes were diagnosed (12 episodes/1000 CVC-days), with primary success with alteplase in 596 episodes (77%) and secondary in 81 cases (10%). In 99 episodes (13%), success was not achieved after the second dose of alteplase. Two hundred and thirty CVC were removed during the study and the removal causes were arteriovenous fistula use in 88 patients (38.3%), infectious and mechanical complications in 89 (38.7%) and 21 (9.1%), respectively, and others (transplantation, transfer, or death) in 32 patients (13.9%). Adverse effects were also not observed. In the multivariate analysis, we identified the greatest number of days with CVC (OR = 1.02, CI = 1.01–1.04, P = 0.004), the presence of diabetes (OR = 1.560, CI = 1.351–1.894, P = 0.015), and exit site infection (ESI) (OR = 1.567 CI = 1347–1926, P = 0.023) as factors associated with obstruction. Thrombotic occlusion showed frequent mechanical complication in CVC of HD patients. We observed 12 episodes of obstruction per 1000 CVC-days, with a high success rate after alteplase use (87%). In the multivariate analysis, the time with CVC, the presence of diabetes, and ESI were identified as variables associated with thrombotic obstruction.
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Objective To study the association between maternal preeclampsia and neonatal sepsis in very low birth weight newborns.Study design We studied all infants with birth weights between 500 g and 1500 g who were admitted to 6 neonatal intensive care units of the Brazilian Network on Neonatal Research for 2 years. Exclusion criteria were major malformations, death in the delivery room, and maternal chronic hypertension. Absolute neutrophil count was performed in the first 72 hours of life.Results A total of 911 very low birth weight infants (preeclampsia, 308; non-preeclampsia, 603) were included. The preeclampsia group had significantly higher gestational age, more cesarean deliveries, antenatal steroid, central catheters, total parenteral nutrition, and neutropenia, and less rupture of membranes >18 hours and mechanical ventilation. Both groups had similar incidences of early sepsis (4.6% and 4.2% in preeclampsia and non-preeclampsia groups, respectively) and late sepsis (24% and 22.1% in preeclampsia and non-preeclampsia groups, respectively). Vaginal delivery and neutropenia were associated with multiple logistic regressions with early sepsis, and mechanical ventilation, central catheter, and total parenteral nutrition were associated with late sepsis. Death was associated with neutropenia in very preterm infants.Conclusions Preeclampsia did not increase neonatal sepsis in very low birth weight infants, and death was associated with neutropenia in very preterm infants. (J Pediatr 2010; 157: 434-8).
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biociências e Biotecnologia Aplicadas à Farmácia - FCFAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The influence of endometrial cavity length (ECL) on implantation and pregnancy rates after 400 embryo transfers was studied prospectively in a population with the indication of IVF/intracytoplasmic sperm injection (ICSI). The tip of the transfer catheter was placed above or below the half point of the ECL in a randomized manner. Two analyses were performed: (i) absolute position (AP); embryo transfers were divided into three groups according to the distance between the end of the fundal endometrial surface and the catheter tip (DTC - distance tip catheter): AP 1 (n = 212), 10-15 mm; AP 2 (n = 158), 16-20 mm; and AP 3 (n = 30), ≥21 mm. (ii) relative position (RP) - embryo transfers were divided into four groups according to their RP [RP = (DTC/ECL) × 100]: RP 1 (n = 23), ≤40%; RP 2 (n = 177), 41-50%; RP 3 (n = 117), 51-60%; and RP 4 (n = 83), ≥61%. Analysis based on relative distance revealed significantly higher implantation and pregnancy rates (P < 0.05) in more central areas of the ECL. However, analysis based on absolute position did not reveal any difference. In conclusion, the present results demonstrated that implantation and pregnancy rates are influenced by the site of embryo transfer, with better results being obtained when the catheter tip is positioned close to the middle area of the endometrial cavity. In this respect, previous analysis of the ECL is the fundamental step in establishing the ideal site for embryo transfers.
Resumo:
Semiquantitative (Maki) and quantitative (Brun- Buisson) culture techniques were employed in the diagnosis of catheter-related bloodstream infections (CRBSI) in patients who have a short-term central venous catheter (inserted for 30 days). The diagnosis of CRBSI was based on the results of semiquantitative and quantitative culture of material from the removed catheters. Catheter tips (118) from 100 patients were evaluated by both methods. Semiquantitative analysis revealed 34 catheters (28.8%) colonized by ≥15 colonyforming units (cfu), while quantitative cultures (34 catheters, 28.8%) showed the growth of ≥103 cfu/mL. Bacteremia was confirmed in four patients by isolating microorganisms of identical species from both catheters and blood samples. Using the semiquantitative culture technique on short-term central venous catheter tips, we have shown that with a cut-off level of ≥15 cfu, the technique had 100.0% sensitivity, specificity of 68.4%, 25.0% positive predictive value (PPV) and 100.0% negative predictive value (NPV), efficiency of 71.4% and a prevalence of 9.5%. The quantitative method, with a cut-off limit of ≥103 cfu/mL, gave identical values: the sensitivity was 100.0%, specificity 68.4%, positive predictive value (PPV) 25.0%, negative predictive value (NPV) 100.0%, efficiency 71.4% and prevalence 9.5%. We concluded that the semiquantitative and quantitative culture methods, evaluated in parallel, for the first time in Brazil, have similar sensitivity and specificity. Keywords: central venous catheter; semi-quantitative culture; quantitative culture; catheter-related bacteremia.
Resumo:
Cateteres venosos centrais inseridos em pacientes internados em unidade de terapia intensiva foram avaliados por métodos microbiológicos (cultura semi-quantitativa) e microscopia eletrônica de varredura a fim de detectar adesão microbiana e correlacionar com a cultura de sangue. Durante o período de estudo, foram avaliados 59 pacientes com cateter venoso central. A idade dos pacientes, sexo, sítio de inserção e tempo de permanência do cateter foram anotados. O cateter era de poliuretano não tunelizado e de único lúmen. O sangue para cultura foi coletado no momento da remoção do cateter. de 63 pontas de cateteres, 30 (47,6%) foram colonizadas e a infecção encontrada em 5 (23,8%) cateteres. A infecção foi mais prevalente em 26 pacientes (41,3%) com cateteres inseridos em veia subclávia do que nos 3 (3,2%) inseridos em veia jugular. A infecção foi observada com mais freqüência em cateteres com tempo de permanência maior do que sete dias. Os microrganismos isolados incluíram 32 estafilococos coagulase-negativa (29,7%), 61 bactérias Gram-negativas (52,9%), 9 estafilcocos coagulase-positiva (8,3%) e 3 leveduras (2,7%). Como agentes causais de infecções em unidade de terapia intensiva foram isolados E. aerogenes, P. aeruginosa, A. baumannii. Os antimicrobianos com maior atividade in vitro contra as bactérias Gram-negativas foram o imipenem e contra as Gram-positivas vancomicina, cefepime, penicilina, rifampicina e tetraciclina. As análises por microscopia eletrônica de varredura revelaram biofilmes sobre a superfície de todos os cateteres examinados.
Resumo:
As infecções devido a biofilmes bacterianos são comuns em pacientes sob tratamento em hemodiálise. Neste estudo, 16 pacientes (7 homens, 9 mulheres, de 22 a 81 anos, média 50 anos de idade), com um total de 25 cateteres de hemodiálise (3 de triplo-lúmen e 22 de duplo-lúmen) de poliuretano inseridos em veia subclávia foram estudados. Os cateteres permaneceram no local de 3 a 91 dias (média de 47 dias). Os cateteres foram removidos devido ao: mau funcionamento (44%), suspeita de infecção relacionada ao cateter (20%), viabilidade de um acesso permanente (16%), remoção acidental (12%), sinais e sintomas de infecção no local da inserção do cateter (4%) e contaminação exógena (4%). Culturas positivas de ponta foram observadas em sete cateteres (28%), concomitantemente com três culturas positivas de sangue. Das culturas de sangue foram identificados Staphylococcus aureus (12%) e de uma das conexões foi isolado S. aureus. Biofilmes foram observados sobre todas as pontas de cateteres. Os S. aureus isolados do sangue e cateter (ponta e conexão) eram resistentes a pencilina e sensíveis a azitromicina, ciprofloxacina, clindamicina, cloranfenicol, gentamicina, oxacilina, rifampicina, sulfametoxazole, tetraciclina e vancomicina. As cepas de S. aureus isoladas de sangue, ponta de cateter e conexão foram consideradas idênticas devido à coincidência do perfil de sensibilidade. E similaridade genética, avaliada por meio de ribotipagem.
Resumo:
A total of 63 pregnancies (47 singleton, 15 twin, 1 triplet) from intracytoplasmic sperm injection cycles were analysed. In all embryo transfers, the catheter was introduced into the endometrial cavity guided by abdominal ultrasound, with the catheter tip placed at the middle point of the endometrial cavity. Gestational sacs (GS) were located 21-24 days after transfer (gestational age = 5 weeks) by two-dimensional and three-dimensional transvaginal ultrasound. The uterine cavity was divided into three parts: upper, middle and lower. Furthermore, the upper region was subdivided into right, middle and left areas, and the middle region was subdivided into right and left areas. The frequency of gestational sacs in each area was evaluated. In singleton pregnancies 66.0% (31/47) of the GS were detected in the upper region, 29.8% (14/47) in the middle region and 4.2% (2/47) in the lower region. In multiple pregnancies (twins and triplet) 45.5% (15/33) of the GS were detected in the upper region, 51.5% (17/33) in the middle region and 3.0% (1/33) in the lower region. In conclusion, the results demonstrate that when embryos are transferred to the central area of the uterine cavity there is an increase in implantation rate in the middle region compared with the rate expected in naturally conceived pregnancies (9-15%).
Resumo:
Slime production is an important virulence factor of coagulase-negative Staphylococcus spp., allowing them to attach to smooth surfaces of biomaterials, and it has been associated with infections of implanted medical devices. In the present study the production of slime capsules in 27 strains of coagulase-negative Staphylococcus was investigated by culture in Congo Red agar (77.7% positivity), spectrophotometric or microplate method (81.4% positivity) and scanning electron microscopy (88.9% positivity). The resistance of coagulase-negative strains of Staphylococcus to various antimicrobial agents was also determined by agar disk diffusion. The proportion of strains resistant to penicillin G, oxacillin, erythromycin, clindamycin and gentamicin among the slime-producing staphylococci was 88.9%, 70.4%, 81.5%, 66.7% and 59.2%, respectively; all of the coagulase-negative staphylococci were susceptible to vancomycin. The strains isolated from central venous catheters were identified by a conventional method and the API Staph system. The 27 coagulase-negative Staphylococcus strains were identified as: S. saprophyticus (3.7%), S. xylosus (7.4%), S. haemolyticus (14.8%), S. epidermidis (37.0%), S. warneri (14.8%), S. lugdunensis (7.4%), S. hominis (7.4%), S. schleiferi (3.7%) and S. chromogenes (3.7%). It can be concluded that in the most of the coagulase-negative Staphylococcus species there was an association between slime production, the nosocomial origin of the strains and reduced sensitivity to the antibiotics, suggesting a pathogenic potential in the hospital environment.