The purpose of this study was to compare temperature variation during osteotomies with trephine drills under different irrigation conditions: without irrigation, external irrigation, and double irrigation.Synthetic blocks of bone (type I density) were used for drilling procedures with an experimental computed machine, which measured the maximum temperature in the cortical bone during osteotomy with a bone cut that was 5 mm in both diameter and depth. Three groups were formed depending on the irrigation conditions: no irrigation (G1), external irrigation (G2), and double irrigation (G3). Fifty drillings were performed for each group.The average thermal increase in the groups was 21.7 +/- 1.52 A degrees C in G1, 14.2 A +/- 0.70 A degrees C in G2, and 12.4 A +/- 0.75 A degrees C in G3. The results presented statistically significant differences among all groups (alpha = 0.05).The double irrigation technique resulted in a smaller increase in temperature in the cortical bone model, demonstrating a greater efficiency, which may be beneficial when compared to external irrigation alone.The trephine has been widely used in removing small blocks for bone graft, especially the posterior mandible, where the possibility of heating may be higher due to the density of cortical bone in this area. So it is important that the professionals select instruments that can reduce the risks of complications in the proposed treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The purpose of this study was to perform histological and histometric analyses of the repair process of autogenous bone grafts fixed at rat calvaria with ethyl-cyanoacrylate adhesive. Material and Methods: Thirty-two rats were divided into two groups (n=16), Group I - Control and Group II - Adhesive. Osteotomies were made at the right parietal bone for graft obtainment using a 4-mm-diameter trephine drill. Then, the bone segments were fixed with the adhesive in the parietal region of the opposite side to the donor site. After 10 and 30 days, 8 animals of each group were euthanized and the calvarias were laboratorially processed for obtaining hematoxylin and eosin-stained slides for histological and histometric analyses. Results: An intense inflammatory reaction was observed at the 10-day period. At 30 days, this reaction was less intense, despite the presence of adhesive at the recipient-site/graft interface. Graft incorporation to the recipient site was observed only at the control group, which maintained the highest graft size at 10 and 30 days. Conclusions: Although the fragment was stable, the presence of adhesive in Group II did not allow graft incorporation to the recipient site, determining a localized, discrete and persistent inflammatory reaction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: the aim of this study was to evaluate bone regeneration in bone cavities filled with particulate autogenous bone either harvest in blocks and subjected to milling procedures or collected during osteotomy with implant burs. Materials and Methods: In 12 rabbits, 3 noncritical unicortical cavities 7 mm in diameter were prepared with a trephine drill on the right tibia. The cavities were filled respectively with particulate autogenous bone achieved with a manual bone crusher ( particulate group), with particulate autogenous bone obtained using bone collector during osteotomy ( collected group), and with blood clot ( control group). Animals were sacrificed at 7, 15, and 30 days after surgery ( 4 animals for each time period). The sections were examined by histologic and histomorphometric analysis. Results: At 7 days, the samples were filled by coagulum, and bone particles were observed only in the collected (24%) and particulate groups (44.75%). At 15 days, there was connective differentiation in all groups, with presence of grafted bone particles and onset of newly formed bone in the collected (38.88%) and particulate groups (46.0%). At 30 days, there was bone fill ( immature trabecular bone) of the cavities in the control (50%), collected (64.63%) and particulate groups (66%). Conclusion: No significant difference was demonstrated between noncritical unicortical bone defects in rabbit tibiae filled with particulate bone harvested as a block and subjected to milling and those filled with bone collected during osteotomy with implant drills when the defects were observed up to 30 days following their creation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to assess the bone repair process of crystallized Biosilicate in surgically created defects on rats' calvaria. This biomaterial was recently developed for odontological use. We used fifteen rats (rattus norvegicus albinus, Wistar), and two 5 mm surgical defects were performed on each of them; the defects were made with trephine drill on the calvarium region prior to the biomaterial placement. Groups were divided as follows: Group 1-defect filled with clot; Group 2-defect filled with crystallized Biosilicate. After 7, 14 and 28 days the animals were killed, the parts were retrieved and slides were prepared for histological studies. Bone formation was satisfactory in all groups, with direct contact between biomaterial surface and bone and absence of infection signs. The 28 days periods showed better results, and statistically significant difference between Clot Group (90.2 %) and Biosilicate (58 %; p = 0.002) was seen, regarding presence of bone tissue on the surgical defects. Our study revealed that defects filled with clot present better results on bone formation compared to crystallized Biosilicate, which is considered a biocompatible material with favorable osteoconductive properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The principles of tissue regeneration to repair alveolar bone defects are based on the fabrication of a biologic barrier with different biomaterials. Therefore, the present study aimed to investigate the guided bone regeneration (GBR) by using membrane of demineralized bovine bone matrix (DBBM) on experimental defects in tibia of dogs. Methods: Four dogs were used and after anesthesia, shaving and antisepsis, two standardized bone defects were created on the right tibia of each animal with trephine drill. In the Control Group, the defects were filled with blood coagulum, while in the Treated Group, a membrane of DBBM was used to cover the defects. After 90 days, animals were sacrificed. Results: In the Treated Group, 67.4% of new bone formation was observed and, in the Control Group, 32.6% of the bone tissue reabsorbed when compared with initial bone volume. The membrane remained intact and no inflammatory tissue was observed on membrane/ bone interface. Conclusion: It was concluded that the use of DBBM is an osteoconductive material, presents biocompatibility and may be promise option to repair bone defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate histomorphometrically the effect of alveolex (Propolis 10%) on the repair of bone cavities in the calvaria of rats. MATERIALS and METHODS: A 5 mm diameter bone defect was made in the calvaria of male Wistar rats using the drill-type trephine. The defects were filled with rhBMP-21Alveolex, rhBMP-2, Alveolex, or coagulum. Twenty-eight animals with seven subjects on each were sacrificed 30 days after surgery and samples were fixed and embedded in paraffin. Histological sections stained by HE (hematoxylin and eosin) were obtained from the calvaria bone defect and analyzed by a differential point-counting method. RESULTS: Group I and II, rhBMP-21Alveolex and rhBMP-2, respectively, presented higher levels of newly formed bone than other groups (P < 0.001). There were not significant differences between groups I and II (P > 0.05). In addition, there was not significant difference between groups III and IV, Control-Coagulum and Alveolex, respectively (P > 0.05). CONCLUSION: Alveolex has increased the bone repair in calvaria defects of rats when associated to rhBMP-2, however without significant differences for rhBMP-2 isolated group; Alveolex isolated group showed the lowest levels of newly formed bone with no significant differences to coagulum group (control). Microsc. Res. Tech. 75: 36-41, 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Newly discovered benthic fossils and specimens illustrated in the paleontological literature indicate that drilling predators (or parasites) were present in the Permian. New field data from southern Brazil document the first drill holes ever reported for Permian bivalve mollusks. In addition, a literature review revealed drill holes in shells of articulate brachiopods from Russia, Greece, and West Texas. Holes range in size from 0.1 to 5.8 mm and are typically round, cylindrical, singular penetrations perpendicular to the valve surface. Incomplete, healed, and multiple holes are absent. Drilling frequency, a proxy for predation intensity, is very low: less than 1 percent (this estimate may be seriously affected by taphonomic and monographic biases). Literature data suggest that frequency of drilled specimens varied significantly among higher brachiopod taxa. The geography and stratigraphy of drilled specimens indicate that drilling organisms were worldwide in their occurrence and continuously present in marine ecosystems throughout the Permian. This report is consistent with other recent studies indicating that although drillers were continuously present throughout the Phanerozoic, drilling intensity was lower in the Late Paleozoic and early Mesozoic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the bone healing in spontaneously hypertensive rats (SHR) and compare the results with normotensive rats, evaluating male and female animals.Methods: A bone drill defect was created in the left femur of 24 SHR (12 males and 12 females) and 24 normotensive rats (12 males and 12 females). The animals were divided into two groups and sacrificed 7 and 21 days after the surgical procedure. After the routine laboratory processing, histological and histometric analysis were carried out and data were submitted to ANOVA and Tukey's test (5%).Results: Males and females from the same group had similar histological characteristics. After seven days, all animals presented irregular bone trabeculae. The periosteal osteoblasts were flattened in SHR, and presented a cuboid shape in normotensive animals. After 21 days, the bone defects of all specimens showed a linear closure in all the superficial extension. In addition, SHR presented flattened osteoblasts surrounding the bone trabeculae, while normotensive ones showed cuboidal cells. Statistical analysis of the histometric data indicated similar means between the male and female groups, except for normotensive rats on day 7. In addition, a larger amount of new bone formation was observed in hypertensive when compared to normotensive rats on day 27, in males as well as females.Conclusion: We conclude that bone healing in SHR was more significant than in normotensive ones, as shown by the histological and histometric evaluation 21 days after surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of soil drill rod length on the N value in the SPT-T test has been studied extensively by Mello (1971), Schmertmann & Palacios (1979), Odebrecht et al. (2002) and Cavalcante (2002). This paper presents an analysis of the Standard Penetration Test supplemented with torque measurement (SPT-T). A theoretical study of the resistance of the rod material to torsion and bending indicated that the shear stress caused by the rod self-weight represents less than 1% of that caused by the torsional moment. An experimental study with electric torquemeters attached to a horizontal rod system, as well as two field tests in the vertical direction, were also carried out to compare and substantiate the results. The purpose of these tests was to analyze changes along the length of the rod in response to successive increments at 1-meter intervals. Torque measurements were taken at each increment of the length to ascertain the accuracy of the theoretical data. The difference between the applied torque and the measured torque at the end of rod system was lower than the minimum scale of mechanical torquemeters used in practice.