239 resultados para Treatment time

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article reports on a series of experiments with polyethylene terepthalate (PET) treated in a radio frequency plasma reactor using argon and oxygen as a gas fuel, for treatment times equal to 5 s, 20 s, 30 s, and 100 s. The mechanical strength modification of PET fibers, evaluated by tensile tests on monofilaments, showed that oxygen and argon plasma treatment resulted in a decrease in the average tensile strength compared with the untreated fibers. This reduction in tensile strength is more significant for argon plasma and is very sensitive to the treatment time for oxygen plasma. Scanning electron microscopy (SEM) used to analyze the effects of cold plasma treatment on fiber surfaces indicates differences in roughness profiles depending on the type of treatments, which were associated with variations in mechanical strength. Differences in the roughness profile, surveyed through an image analysis method, provided the distance of roughness interval, D-ri. This parameter represents the number of peaks contained in a unit length and was introduced to correlate fiber surface condition, before and after cold plasma treatments, and average tensile strength. Statistical analysis of experimental data, using Weibull cumulative distribution and linear representation, was performed to explain influences of treatment time and environmental effects on mechanical properties. The shape parameter, alpha, and density parameter, beta, from the Weibull distribution function were used to indicate the experimental data range and to confirm the mechanical performance obtained experimentally.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective. To compare clinical response to initial empiric treatment with oxacillin plus ceftriaxone and amoxicillin plus clavulanic acid in hospitalized children diagnosed with very severe community-acquired pneumonia (CAP).Methods. A prospective randomized clinical study was conducted among children 2 months to 5 years old with a diagnosis of very severe CAP in the pediatric ward of São Paulo State University Hospital in Botucatu, São Paulo, Brazil, from April 2007 to May 2008. Patients were randomly divided into two groups by type of treatment: an oxacillin/ceftriaxone group (OCG, n = 48) and an amoxicillin/clavulanic acid group (ACG, n = 56). Analyzed outcomes were: time to clinical improvement (fever and tachypnea), time on oxygen therapy, length of stay in hospital, need to widen antimicrobial spectrum, and complications (including pleural effusion).Results. The two groups did not differ statistically for age, sex, symptom duration before admission, or previous antibiotic treatment. Time to improve tachypnea was less among ACG patients than OCG patients (4.8 +/- 2.2 versus 5.8 +/- 2.4 days respectively; P = 0.028), as was length of hospital stay (11.0 +/- 6.2 versus 14.4 +/- 4.5 days respectively; P = 0.002). There were no statistically significant differences between the two groups for fever improvement time, time on oxygen therapy, need to widen antimicrobial spectrum, or frequency of pleural effusion.Conclusions. Both treatment plans are effective in treating very severe CAP in 2-monthto 5-year-old hospitalized children. The only analyzed outcome that favored amoxicillin/clavulanic acid treatment was time required to improve tachypnea.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, BSTSn powders prepared by the polymeric precursor method were heat treated in a domestic microwave oven (MW) using a SiC susceptor to absorb the microwave energy and transfer the heat to the powder. The main advantage of MW is to reduce the thermal treatment time for phase crystallization. The powders were heat treated at 300 degrees C for 20 h in conventional oven, 300 degrees C for 10 min, 20 min, and 30 min in MW and at 500 degrees C for 1 min in MW. After thermal treatment, the photoluminescent properties of powders at room temperature were analyzed. (c) 2007 Published by Elsevier B.V.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nitrogen implantation into Ti alloys at higher temperatures improves their mechanical and corrosion resistance properties by forming a thicker nitride layer. In this paper, two different sets of Ti-6Al-4V samples were plasma immersion ion implantation (PIII)-treated using nitrogen plasma, varying the treatment time from 30 to 150 min (800 degrees C) and the process temperature from 400 degrees C to 800 degrees C (t = 60 min). Nanoindentation measurements of the PIII-treated samples at 800 C during 150 min showed the highest hardness value, 24 GPa, which is about four times bigger than untreated sample hardness. The N penetration at these conditions reached approximately 150 nm as analyzed by Auger spectroscopy. on the other hand, the lowest passive current density (3 x 10(-7) A. cm(-2)) was obtained for a PIII-treated sample during 30 min at higher temperature (800 degrees C). The corrosion resistance of this sample is almost the same as for the untreated specimen. Corrosion behavior evidenced that in strong oxidizing media, all PIII-treated samples are more corrosion resistant than the untreated one. PIII processing at higher temperatures promotes smoothing of the sample surface as observed by scanning electron microscopy (SEM). Grazing incidence X-ray diffraction analyses of the untreated samples identified the two typical Ti phases, Ti alpha and Ti beta. After the implantation, Ti2N and TiO2 phases were also detected.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: This article reports preliminary clinical results of the Speed Master system, a method for immediate loading of implants for the treatment of mandibular edentulism. Materials and Methods: Fifteen patients with edentulous mandibles were consecutively included in the study. Each received 4 implants between the mental foramina placed using the system's surgical guides. Permanent fixed prostheses fabricated over premanufactured titanium bars were attached to the implants on the day of implant placement. The patients were followed for 15 to 27 months (mean, 19 months). Peri-implant tissues were periodically evaluated. Marginal bone loss was monitored with periapical radiographs using a computerized technique. Satisfaction was assessed by means of a questionnaire. Results: The overall implant and prosthetic survival rates were 100%. At the time of the final follow-up visit, mean marginal bone loss was 1.11 mm, and bleeding on probing was not observed. Only 6.7% of the patients reported any discomfort during treatment, and all patients would recommend the procedure to others. Discussion: The immediate loading of implants placed in the edentulous mandible with the Speed Master surgical and prosthetic protocol reduces treatment time and number of surgical procedures in comparison to classic delayed loading protocols. Conclusion: The rehabilitation of the mandible with an immediately delivered occlusally loaded hybrid prosthesis supported by 4 implants does not appear to jeopardize the success of the osseointegration and represents a viable treatment option.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To investigate the effects of the standard (Class II) Balters bionator in growing patients with Class II malocclusion with mandibular retrusion by using morphometrics (thin-plate spline [TPS] analysis). Materials and Methods: Thirty-one Class II patients (17 male and 14 female) were treated with the Balters bionator (bionator group). Mean age at the start of treatment (T0) was 10.3 years, while it was 13 years at the end of treatment (T1). Mean treatment time was 2 years and 2 months. The control group consisted of 22 subjects (14 male and 8 female) with untreated Class II malocclusion. Mean age at T0 was 10.2 years, while it was 12.2 years at T1. The observation period lasted 2 years on average. TPS analysis evaluated statistical (permutation tests) differences in the craniofacial shape and size between the bionator and control groups. Results: Through TPS analysis (deformation grids) the bionator group showed significant shape changes in the mandible that could be described as a mandibular forward and downward displacement. The control group showed no statistically significant differences in the correction of Class II malocclusion. Conclusions: Bionator appliance is able to induce significant mandibular shape changes that lead to the correction of Class II dentoskeletal disharmony. © 2013 by The EH Angle Education and Research Foundation, Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The effect of heat-moisture treatment on structural, physicochemical, and rheological characteristics of arrowroot starch was investigated. Heat-moisture treatment was performed with starch samples conditioned to 28% moisture at 100℃ for 2, 4, 8, and 16 h. Structural and physicochemical characterization of native and modified starches, as well as rheological assays with gels of native and 4 h modified starches subjected to acid and sterilization stresses were performed. Arrowroot starch had 23.1% of amylose and a CA-type crystalline pattern that changed over the treatment time to A-type. Modified starches had higher pasting temperature and lower peak viscosity while breakdown viscosity practically disappeared, independently of the treatment time. Gelatinization temperature and crystallinity increased, while enthalpy, swelling power, and solubility decreased with the treatment. Gels from modified starches, independently of the stress conditions, were found to have more stable apparent viscosities and higher G' and G″ than gels from native starch. Heat-moisture treatment caused a reorganization of starch chains that increased molecular interactions. This increase resulted in higher paste stability and strengthened gels that showed higher resistance to shearing and heat, even after acid or sterilization conditions. A treatment time of 4 h was enough to deeply changing the physicochemical properties of starch.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conscious sedation has become established as an important alternative to general anesthesia (GA) in dental treatment of patients with intellectual disability (ID). Aim: to investigate dental patients undergoing sedation using a mean dose of 0.6 mg/kg intravenous midazolam and the adverse events of sedation in patients with ID. Methods: This study analyzed the records of 163 dental patients with ID aged between 2 and 76 years who had undergone conscious intravenous sedation (CIV) using a mean dose of 0.61 mg/kg of midazolam at Araçatuba Dental School, São Paulo State University, Brazil. The efficacy and complications induced by CIV were evaluated in each subject. Results: CIV was effective for dental treatment in 80% of the cases. A total of 626 dental procedures were performed. The mean treatment time was 33.9 minutes. There was statistically significant difference (p<0.05) between absence and presence of adverse reactions. Adverse reactions were observed in 21.47% of the cases. Conclusions: The results of this study showed that CIV is a useful method for dental treatment of patients with ID and these patients can need higher doses of sedative to reach an adequate level of sedation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Curaua fibers were treated with ionized air to improve the fiber/phenolic matrix adhesion.The treatment with ionized air did not change the thermal stability of the fibers. The impact strength increased with increase in the fiber treatment time. SEM micrographs of the fibers showed that the ionized air treatment led to separation of the fiber bundles. Treatment for 12 h also caused a partial degradation of the fibers, which prompted the matrix to transfer the load to a poorer reinforcing agent during impact, thereby decreasing the impact strength of the related composite. The composites reinforced with fibers treated with ionized air absorbed less water than those reinforced with untreated fibers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ti-6Al-4V alloy is one of the most frequently used Ti alloys with diverse applications in aerospace and biomedical areas due to its favorable mechanical properties, corrosion resistance and biocompatibility. Meanwhile, its surface can stiffer intense corrosion caused by wear processes due to its poor tribological properties. Thus in the present study, PIII processing of Ti-6Al-4V alloy was carried out to evaluate its corrosion resistance in 3.5% NaCl solution. Two different sets of Ti-6Al-4V samples were PIII treated, varying the plasma gases and the treatment time. The corrosion behavior is correlated with the surface morphology, and the nitrogen content. SEM micrographs of the untreated sample reveal a typical two-phase structure. PIII processing promotes surface sputtering and the surface morphology is completely different for samples treated with N-2/H-2 mixture and N-2 only. The highest penetration of nitrogen (similar to 88 nm), corresponding to 33% of N-2 was obtained for the sample treated with N-2/H-2 mixture for 1:30 h. The corrosion behavior of the samples was investigated by a potentiodynamic polarization method. A large passive region of the polarization curves (similar to 1.5 V), associated with the formation of a protective film, was observed for all samples. The passive current density (similar to 3 x 10(-6) A cm(-2)) of the PIII-treated Ti-6Al-4V samples is about 10 times higher than for the untreated sample. This current value is still rather low and maintains good corrosion resistance. The anodic branches of the polarization curves for all treated Ti-6Al-4V samples demonstrate also that the oxide films break down at approximately 1.6 V, forming an active region. Although the sample treated by N-2/H-2 mixture for 1.30 It has thicker nitrogen enriched layer, better corrosion resistance is obtained for the PIII process performed with N, gas only. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the effect of nitrogen Plasma Immersion Ion Implantation (PIII) on chemical structure, refraction index and surface hardness of plasma-polymerized hexamethyldisilazane (PPHMDSN) thin films. Firstly, polymeric films were deposited at 13.56 MHz radiofrequency (RF) Plasma Enhanced Chemical Vapour Deposition (PECVD) and then, were treated by nitrogen PIII from 15 to 60 min. Fourier Transformed Infrared (FTIR) spectroscopy was employed to analyse the molecular structure of the samples, and it revealed that vibrations modes at 3350 cm(-1), 2960 cm(-1), 1650 cm(-1), 1250 cm(-1) and 1050 cm(-1) were altered by nitrogen PIII. Visible-ultraviolet (vis-UV) spectroscopy was used to evaluate film refractive index and the results showed a slight increase from 1.6 to 1.8 following the implantation time. Nanoindentation revealed a surface hardness rise from 0.5 to 2.3 GPa as PIII treatment time increased. These results indicate nitrogen PIII is very promising in improving optical and mechanical properties of PPHMDSN films.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: a reabsorção radicular apical é uma condição comumente observada durante e após o tratamento ortodôntico e fatores como tipo de aparelhagem ortodôntica utilizada, magnitude das forças aplicadas e duração do tratamento podem estar relacionados ao processo de arredondamento do ápice radicular. Buscou-se avaliar, por meio de imagens radiográficas computadorizadas, a quantidade de reabsorção no ápice radicular, quando da utilização de duas diferentes técnicas de mecânica ortodôntica fixa: Edgewise com acessórios padrão e Edgewise com acessórios totalmente programados. METODOLOGIA: a amostra constituiu-se de 20 pacientes tratados pelo mesmo profissional na Clínica de Ortodontia da Faculdade de Odontologia de Araçatuba - UNESP. Os pacientes foram divididos em dois grupos: grupo 1 (Tratados com Edgewise com acessórios padrão e fios de aço) e grupo 2 (Tratados com Edgewise com acessórios totalmente programados e fios de níquel-titânio). A avaliação radiográfica digital foi realizada por um único operador por meio de exposições radiográficas digitais feitas no início do tratamento ortodôntico, após retração de caninos e final de tratamento, utilizando o sistema de escores proposto por Levander e Malmgren (1988). RESULTADOS E CONCLUSÕES: a análise dos escores permitiu concluir que o tratamento ortodôntico empregando a técnica Edgewise com acessórios totalmente programados e fios de níquel-titânio apresentou menores graus de reabsorção radicular apical, em comparação à técnica Edgewise com acessórios padrão e fios de aço. Observou-se que, independentemente da técnica empregada, o tratamento ortodôntico como um todo apresentou um grau moderado de reabsorção radicular apical.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente estudo foi realizado com o propósito de avaliar respostas cefalométricas ao tratamento com aparelho extrabucal de Kloehn associado ao aparelho fixo edgewise convencional. Telerradiografias iniciais (T1) e finais (T2) de dois grupos de 30 pacientes tratados com estes aparelhos foram selecionadas e definidas pelo índice cefalométrico de Jarabak para determinação do padrão esquelético craniofacial. Os grupos foram denominados favorável (hipodivergente) e desfavorável (hiperdivergente). A idade média, no início do tratamento, foi de 11,03 anos e final de 14,72 com o tempo médio de tratamento de 3,6 anos para o grupo favorável. No grupo desfavorável a idade inicial foi de 11,51 anos e final de 15,17 anos com tempo médio de tratamento de 3,4 anos. Foi utilizado um sistema de análise de resposta de tratamento em coordenadas X e Y representativos dos movimentos dentários e das bases ósseas decompondo-os em seus vetores horizontais e verticais. Os resultados e respostas do tratamento foram analisados e comparados entre os grupos favorável e desfavorável utilizando o teste t-Student. Os resultados mostraram não haver diferenças estatisticamente significantes na resposta cefalométrica no tratamento com o aparelho extrabucal de Kloehn associados ao aparelho fixo edgewise quanto aos padrões faciais favorável e desfavorável. O tratamento promoveu uma restrição do deslocamento anterior maxilar e um menor deslocamento anterior mandibular. Quanto à movimentação dentária maxilar, houve uma restrição do movimento mesial e extrusivo dos molares superiores no grupo favorável, enquanto que o movimento dos dentes inferiores foi mínimo no sentido anterior e vertical.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and aims: Staphylococcus epidermidis and other coagulase-negative staphylococci (CoNS) are the most common agents of continuous ambulatory peritoneal dialysis (CAPD) peritonitis. Episodes caused by Staphylococcus aureus evolve with a high method failure rate while CoNS peritonitis is generally benign. The purpose of this study was to compare episodes of peritonitis caused by CoNS species and S. aureus to evaluate the microbiological and host factors that affect outcome. Material and methods: Microbiological and clinical data were retrospectively studied from 86 new episodes of peritonitis caused by staphylococci species between January 1996 and December 2000 in a university dialysis center. The influence of microbiological and host factors (age, sex, diabetes, use of vancomycin, exchange system and treatment time on CAPD) was analyzed by logistic regression model. The clinical outcome was classified into two results (resolution and non-resolution). Results: the odds of peritonitis resolution were not influenced by host factors. Oxacillin susceptibility was present in 30 of 35 S. aureus lineages and 22 of 51 CoNS (p = 0.001). There were 32 of 52 (61.5%) episodes caused by oxacillin-susceptible and 20 of 34 (58.8%) by oxacillin-resistant lineages resolved (p = 0.9713). of the 35 cases caused by S. aureus, 17 (48.6%) resolved and among 51 CoNS episodes 40 (78.4%) resolved. Resolution odds were 7.1 times higher for S. epidermidis than S. aureus (p = 0.0278), while other CoNS had 7.6 times higher odds resolution than S. epidermidis cases (p = 0.052). Episodes caused by S. haemolyticus had similar resolution odds to S. epidermidis (p = 0.859). Conclusions: S. aureus etiology is an independent factor associated with peritonitis non-resolution in CAPD, while S. epidermidis and S. haemolyticus have a lower resolution rate than other CoNS. Possibly the aggressive nature of these agents, particularly S. aureus, can be explained by their recognized pathogenic factors, more than antibiotic resistance.