24 resultados para Thermal storage

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper analyzes the thermal storage characteristics of aluminum plates in furnaces during their heating for lamination under two sources of heat: an electrical resistance bank and a combustion process carried out with natural gas. The set of equations to model the furnace under operation with electrical energy, for air as the fluid, is presented. This supports the theoretical analysis for the system under operation with natural gas combustion products. A numerical procedure, using the software ANSYS, is applied to determine the convection heat transfer coefficients for heating by the air flow. Temperatures measured in a plate inside a real furnace are used as parameters to determine these coefficients. Then convection and radiation heat transfer coefficients are determined for the natural gas combustion products. Results are compared, indicating a possible gain of 5.5 h in relation to a 19.5 h period of conventional electrical heating per plate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An experimental apparatus containing a domestic refrigerator coupled to a vertical hot water storage tank was used for energy recovery. The original condenser of the refrigerator was maintained, but modified with a concentric tubes heat exchanger with countercurrent water and refrigerating gas flows. The coefficient of performance for the heat pump is calculated by the ratio of energy in the heat storage and the electric power consumed by the domestic refrigerator compressor. The results show that the increasing of hydrostatic pressure in the storage tank increases the water flow rate and the coefficient of performance. The proposed device also reduces the heat dissipation to the surroundings. This is more important in small confinements found in low-cost houses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper is proposed the usage of an Organic Rankine Cycle (ORC) along with waste heat recovery from an inconstant heat source. This method of waste heat recovery with intermittent heat source is part of a technical viability study. This paper also brings up the usage of thermal energy storage as heat source for the ORC. This paper is based on a heat treatment company study in which a natural gas furnace is explored. Data such as mass flow, temperature and specific waste gas heat from this furnace are used through calculations. Calculations are made also based on furnace cycles. This viability study considers a series of working fluids such as ammonia, benzene, R113 and R134a. Results point out that ORC with out thermal storage and using refrigerant fluid ammonia is the best alternative

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A mathematical model was developed in order to study the behavior of thermal stratification of liquid in a typical storage tank with porous medium. The model employs a transient stream function-vorticity formulation to predict the development of stream function and temperature fields in a charging process. Parameters analyzed include Biot, Darcy, Reynolds and Richardson numbers, position, and the thickness of the porous medium. The results show the influence of these physical parameters that should be considered for a good design of storage tanks with thermal stratification.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We discuss the influence of the background thermal bath on the depolarization of electrons in high-energy storage rings, and on the photon emission associated with the spin flip. We focus, in particular, on electrons at CERN LEP. We show that in a certain interval of solid angles the photon emission is enhanced several orders of magnitude because of the presence of the thermal bath. Notwithstanding, the overall depolarization induced by the background thermal bath at LEP conditions is much smaller than the one induced by plain acceleration at zero temperature and can be neglected in practical situations. Eventually we discuss under what conditions the background thermal bath can enhance the overall depolarization by several orders of magnitude.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study aimed to evaluate the effect of different storage periods in artificial saliva and thermal cycling on Knoop hardness of 8 commercial brands of resin denture teeth. Methods: Eigth different brands of resin denture teeth were evaluated (Artplus group, Biolux group, Biotone IPN group, Myerson group, SR Orthosit group, Trilux group, Trubyte Biotone group, and Vipi Dent Plus group). Twenty-four teeth of each brand had their occlusal surfaces ground flat and were embedded in autopolymerized acrylic resin. After polishing, the teeth were submitted to different conditions: (1) immersion in distilled water at 37 ± 2 °C for 48 ± 2. h (control); (2) storage in artificial saliva at 37 ± 2 °C for 15, 30 and 60 days, and (3) thermal cycling between 5 and 55 °C with 30-s dwell times for 5000 cycles. Knoop hardness test was performed after each condition. Data were analyzed with two-way ANOVA and Tukey's test (α= .05). Results: In general, SR Orthosit group presented the highest statistically significant Knoop hardness value while Myerson group exhibited the smallest statistically significant mean (P< .05) in the control period, after thermal cycling, and after all storage periods. The Knoop hardness means obtained before thermal cycling procedure (20.34 ± 4.45 KHN) were statistically higher than those reached after thermal cycling (19.77 ± 4.13 KHN). All brands of resin denture teeth were significantly softened after storage period in artificial saliva. Conclusion: Storage in saliva and thermal cycling significantly reduced the Knoop hardness of the resin denture teeth. SR Orthosit denture teeth showed the highest Knoop hardness values regardless the condition tested. © 2010 Japan Prosthodontic Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The combinations of temperature and time which can cause chilling injuries in avocados 'Geada', 'Quintal' and 'Fortuna' were determined. The binomial 4 degrees C/ 28 days was selected to determine the activity of peroxidase (POD), polyphenoloxidase (PPO), polygalacturonase (PG) and methylesterase pectin (PME). The respiratory activity was also evaluated. The fruits were stored at this condition until being transferred to ambient conditions (22 degrees C and 77% RH) until maturity, when they were compared to fruits stored permanently at this environment, after being cleaned (control). In the second part of this work, different hydrothermal treatments were tested to prevent or minimize chilling injuries. Avocados 'Geada', 'Quintal' and 'Fortuna' were treated at 38 degrees C for 0, 30, 60 and 90 minutes before storage at 4 degrees C for 28 days. It was observed that the activity of enzymes associated to browning, POD and PPO, and to maturation, PG and PME, had become greater in fruits stored at 4 degrees C, or when they were transferred to environmental conditions. Fruits subjected to refrigeration, after transferred to environment, presented lower respiratory peak intensity and it occurred earlier than the others. Treatments using 38 degrees C for 60 and 90 min minimized the symptoms of chilling injury in avocados 'Geada' while for 'Quintal' the most efficient was 38 degrees C for 60 min. In 'Fortuna' these treatments did not minimize the damage by cold.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermal stability, thermal decomposition process, residual mass, temperature of glass transition (T-g) and temperature dependence of storage modulus (E'), were determined for latex membranes prepared from six clones of Hevea brasiliensis: IAC 331, IAC 332, IAC 333 and IAC 334 grown at experimental plantations of Instituto Agronomico de Campinas (IAC) in Votuporanga, São Paulo State, Brazil. Latex membranes from GT1 and RRIM 600 Asian matrix clones were used as references. The thermal behavior of latex membranes from genetically improved rubber trees was characterized using thermogravimetry/derivative thermogravimetry (TG/DTG), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The thermal behavior of latex from clones studied in the present work showed similar features of the clones previously reported (IAC 40, IAC 300, IAC 301, IAC 328, IAC 329 and IAC 330), with mass loss in four consecutive steps, except IAC 333, which showed an additional mass loss step. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)