79 resultados para Tester
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
An 8051-based microcontroller tester has been designed to reduce troubleshooting time of the Electro-Hydraulic Actuators (EHA) installed in fly-by-wire aircrafts. The tester algorithm first evaluates EHA pressure and position sensor signals to emit either a pass or fail message. The evaluation is based on predefined ranges of EHA pressure and position signals. Next, the instrument tests the EHA response capability - a way of dynamic response evaluation, again issuing a suitable response. The instrument proved to be reliable after being successfully evaluated in laboratory and in a real model test airplane. © 2007 IEEE.
Resumo:
Hardness is a property largely used in material specifications, mechanical and metallurgical research and quality control of several materials. Specifically for timber, Janka hardness is a simple, quick and easy test, with good correlations with the compression parallel to grain strength, a strong reference in structural classification for this material. More recently, international studies have reported the use of Brinell hardness for timber assessment which resumes the advantages previously mentioned for Janka hardness and make it easier to be performed in the field, especially because of the lower magnitude of the involved loads. A first generation of an equipment for field evaluation of hardness in wood - Portable Hardness tester for wood - based on Brinell hardness has already been developed by the Research Group on Forest Products from FCA/UNESP, Brazil, with very good correlations between the evaluated hardness and several other mechanical properties of the material when performing tests with different species of native and reforested wood (traditionally used as ties - sleepers - in railways). This paper presents results obtained in the experimental program with the first generation of this equipment and preliminary tests with its second generation, which uses accelerometers to substitute the indentation measurements in wood. For the first generation of the equipment functional and calibration tests were carried out using 16 native and reforestation timber lots, among there E. citriodora, E. tereticornis, E. saligna, E. urophylla, E. grandis, Goupia glabra and Bagassa guianenses, with different origins and ages. The results obtained confirm its potential in the classification of specimens, with inclusion errors varying from 4.5% to 16.6%.
Resumo:
More than 80% of the 29600 km of the Brazilian railroad mesh employs wooden sleepers. The problem of hard availability of native wood for this purpose leads to the alternative use of reforestation species to produce sleepers. Considering the great difficulty to, in field condition, evaluate characteristics that are of major importance to define its suitability to sleeper production the Research Group on Forest Products from FCA/UNESP - Brazil had developed equipment for field evaluation of hardness in wood - Portable Hardness Tester. This paper reports the functional validation tests, performed with different species of Eucalyptus. Results revealed the equipment great functionality, easy-to-use characteristics and applicability to Eucalyptus wood. Moderate to strong relationships between laboratory and validated values of hardness were found. The best validation model was obtained using the data provided by the experimental dispositive 3 (R2=0.74 and SSE= 7.71 kJ/m2) while the experimental dispositive 1 gave the worse validation (R2=0.55 and SSE= 13.46 kJ/m2).
Resumo:
Coeficientes de correlações genéticas e fenotípicas foram estimados entre os caracteres: altura da planta (AP); altura da espiga (AE); peso de espigas (PE) e teor de óleo (TO). As estimativas foram obtidas para duas populações braquíticas de milho (Piranão VD-2 e Piranão VF-1), baseado em espiga por fileira, utilizando-se testemunha intercalar, onde a cada duas progênies plantava-se uma fileira do híbrido simples AG 305-B. Os valores das correlações genéticas aditivas encontradas entre os caracteres altura da planta, altura da espiga e peso de espigas, foram todos positivos. Para o caráter teor de óleo, quando correlacionado com os demais caracteres, os valores das correlações obtidos foram negativos nas duas populações, exceção feita ao peso de espiga correlacionada com teor de óleo, na população Piranão VD-2, cujo valor foi positivo e próximo de zero. As respostas correlacionadas obtidas entre os caracteres, quando a seleção é praticada para o caráter teor de óleo e vice versa, independente do método de seleção empregado, mostram que a seleção para teor de óleo leva a modificação na estrutura da planta, para as duas populações.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A new rot caused by a binucleate Rhizoctonia sp. affecting the tuberous root cortex of the domesticated yacon (Smallanthus sonchifolius) has been observed in Brazil. Isolates of a binucleate Rhizoctonia sp. were collected from roots with rot symptoms and characterized by the number of nuclei per cell, hyphal anastomosis, RAPD molecular markers, ITS-5.8S rDNA sequence and pathogenicity tests. All isolates had a mean of 1.9-2.2 nuclei per cell and anastomosed with the binucleate Rhizoctonia sp. AG G-tester strain. RAPD analysis was carried out between 11 isolates recovered from yacon and 11 AG (A, Ba, Bb, Bo, C, D, F, G, O, P, Q) standard testers of binucleate Rhizoctonia sp. Genetic similarities of 94.8-100% were observed among isolates of the binucleate Rhizoctonia sp. from yacon and all isolates were genetically more closely related to the AG G tester than other strains according to UPGMA analysis using RAPD markers. Homologies of complete ITS nucleotide sequences were 100% between binucleate isolates of Rhizoctonia sp. from yacon and the AG G tester. According to pathogenicity tests, the isolates caused typical rot symptoms of yacon tubers 90 days after inoculation.
Resumo:
No Estado do Tocantins, no Norte do Brasil, a incidência de rizoctoniose no arroz é importante, causando danos significativos em lavouras de arroz irrigado. O principal objetivo deste trabalho foi determinar o grupo de anastomose (AG) de isolados de R. solani associados ao arroz naquela região, testando a hipótese de que esses isolados pertencem ao grupo padrão de anastomose AG-1 IA, que também é o agente causal da mela em soja em áreas úmidas do Norte do Brasil. Todos os quatro isolados de arroz foram caracterizados, através de fusão de hifas, como AG-1 IA. A caracterização cultural, em função das temperaturas basais (mínimas, máximas e ótimas), evidenciou que os isolados de R. solani de arroz apresentaram perfis semelhantes aos padrões AG-1 IA, AG-1 IB e AG-1 IC. Os isolados de arroz foram caracterizados como autotróficos para tiamina assim como os isolados padrões AG-1 IA, IB, IC, AG-4 HGI e o isolado da mela da soja. O teste de patogenicidade em plantas de arroz cultivar IRGA-409 e de patogenicidade cruzada à cultivar IAC-18 de soja (suscetível à mela), indicou que além de causar a queima da bainha em arroz, esses isolados causam mela em soja. da mesma forma, o isolado SJ-047 foi patogênico ao arroz. As seqüências de bases de DNA da região ITS-5.8S do rDNA dos isolados do arroz foram similares às seqüências do AG-1 IA, depositadas no GenBank® - NCBI. A filogenia do ITS-rDNA indicou um grupo filogenético comum formado pelos isolados do arroz, o isolado da soja e o isolado teste do AG-1 IA. Assim, com base em características citomorfológicas, culturais, filogenéticas e patogênicas, foi confirmada a hipótese de que os isolados de R. solani patógenos de arroz do Estado do Tocantins pertencem ao grupo de anastomose AG-1 IA, além da indicação de que esses isolados podem também causar a mela em soja.
Resumo:
This study evaluated: 1) the effect of different ceramics on light attenuation that could affect microhardness, measured as the Knoop Hardness Number (KHN), of a resin cement immediately and 24 hours after polymerization and 2) the effect of different activation modes (direct light-activation, light activation through ceramics and chemical activation) on the KHN of a resin cement.Resin cement Rely X ARC (3M ESPE) specimens 5.0 mm in diameter and 1.0 nun thick were made in a Teflon mold covered with a polyester film. The cement was directly light activated for 40 seconds with an XL 2500 curing unit (3M ESPE) with 650 mW/cm(2), light activated through ceramic discs of Duceram Plus (DeguDent), Cergogold (DeguDent), IPS Empress (Ivoclar), IPS Empress 2 (Ivoclar), Procera. (NobelBiocare), In Ceram Alumina (Vita) and Cercon (DeguDent), having a 1.2 mm thickness or chemically activated without light application. The resin cement specimens were flattened, and KHN was obtained using an HMV 2 microhardness tester (Shimadzu) with a load of 50 g applied for 15 seconds 100 pin from the irradiated surface immediately and after storage at 37 degrees C for 24 hours. Ten measurements were made for each specimen, with three specimens for each group at each time. The data were submitted to ANOVA and Tukey's test (p=0.05). The KHN of the resin cement was not only affected by the mode of activation, but also by the post-activation testing time. The mean KHN of the resin cement for chemical activation and through all ceramics showed statistically significant lower values compared to direct activation immediately and at 24 hours. The KHN for 24 hours post-activation was always superior to the immediate post-activation test except with direct activation. The most opaque ceramics resulted in the lowest KHN values.
Resumo:
The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective. The purpose of this study was to evaluate the effects of endodontic irrigants on the microhardness of root canal dentin.Study design. Thirty extracted single-rooted human teeth were used. The crowns were sectioned at the cementoenamel junction. Each root was transversely sectioned into cervical, middle, and apical segments, resulting in 90 specimens. The 3 sections of each root were separately mounted in an individual silicon device with acrylic resin. The specimens were randomly divided into the following 3 groups (n = 30), according to the irrigant solution used: (1) group 1, control (saline solution); (2) group 2, 2% chlorhexidine gluconate solution; and (3) group 3, 1% sodium hypochlorite (NaOCl). After 15 minutes of irrigation, dentin microhardness was measured on each section at 500 mu m and 1000 mu m from the pulp-dentin interface with a Vickers diamond microhardness tester in Vickers hardness number (VHN).Results. Data obtained were analyzed using analysis of variance and the Tukey test (5%). Specimens irrigated with 2% chlorhexidine (group 2) or 1% NaOCl (group 3) presented lower values of dentin microhardness, with significant difference in relation to the control group (P < .05).Conclusion. It could be concluded that chlorhexidine and NaOCl solutions significantly reduced the microhardness of root canal dentin at 500 mu m and 1000 mu m from the pulp-dentin interface.
Resumo:
There are several methods for identifying carious dentinal tissue aiming to avoid removal of healthy dentinal tissue. Objectives: The purpose of this study was to test different methods for the detection of carious dentinal tissue regarding the amount of carious tissue removed and the remaining dentin microhardness after caries removal. Material and methods: The dentin surfaces of 20 bovine teeth were exposed and half of the surface was protected with nail polish. Cariogenic challenge was performed by immersion in a demineralizing solution for 14 days. After transverse cross-section of the crown, the specimens were divided into four groups (n=10), according to the method used to identify and remove the carious tissue: "Papacarie", Caries-detector dye, DIAGNOdent and Tactile method. After caries removal, the cross-sectional surface was included in acrylic resin and polished. In a microhardness tester, the removed dentin thickness and the Vickers microhardness of the following regions were evaluated: remaining dentin after caries removal and superficial and deep healthy dentin. Results: ANOVA and Tukey's test (alpha=0.05) were performed, except for DIAGNOdent, which did not detect the presence of caries. Results for removed dentin thickness were: "Papacarie" (424.7 +/- 105.0; a), Caries-detector dye (370.5 +/- 78.3; ab), Tactile method (322.8 +/- 51.5; bc). Results for the remaining dentin microhardness were: "Papacarie" (42.2 +/- 10.5; bc), Caries-detector dye (44.6 +/- 11.8; bc), Tactile method (24.3 +/- 9.0; d). Conclusions: DIAGNOdent did not detect the presence of carious tissue; Tactile method and "Papacarie" resulted in the least and the most dentinal thickness removal, respectively; Tactile method differed significantly from "Papacarie" and Caries-detector dye in terms of the remaining dentin microhardness, and Tactile method was the one which presented the lowest microhardness values.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The chemical and biochemical composition of mango, varies according to the cultivation conditions, variety and maturation state, generally containing a high level of ascorbic acid. In order to establish the correlation between the activity of the ascorbate oxidase [E.C.1.10.3.3], and ascorbic acid level in the ripening process of the Haden mango (Mangífera índica L.), sample of the fruits related to hard green stage (zero), 2, 4, 6, 8, 10, 12 and 14 days stored at 20 ± 2oC, were tested. The samples were obtained by cutting small cubes of 8 cm3 from pulps of 8 mangoes with texture without significant difference (p£0.05) at Magness-Taylor pressure tester scale. In each sample the activity of ascorbate oxidase was followed, in order to check its participation in possible substrate losses during the ripening fruits. The ascorbic acid level and sensory profile also was determined periodically during the ripening period. The enzymatic activity was spectrophotometrically determined at 245 nm and 30oC. The ascorbic acid was analyzed according modified AOAC methodology, and sensory analysis by descriptive quantitative analysis. Data were analyzed using correlation analysis, analysis of variance (ANOVA), Tukey's test, principal component analysis and stepwise discriminant analysis. During the ripening, the ascorbate oxidase activity increased (from 0 to 5.0 x 10-1 U/ml) and the ascorbic acid level decreased (from 209.3 mg to 110.0 mg per 100g of pulp), showing a significant (p£0.05) inverse linear correlation (r=-0.98). The descriptors terms for mangoes were: characteristic flavor, characteristic aroma, sourness, astringency, yellow coloration of pulp, sweetness and succulence. The sensory profile presented significant improvement during ripening. All sensory attributes increased significantly (p£0.05) except sourness and astringency, wich decreased during the ripening of mangoes.
Resumo:
INTRODUÇÃO: A utilização da fotogrametria computadorizada em prol da goniometria, ou vice-versa, na prática clínica ainda necessita de fundamentações consistentes. OBJETIVOS: Os objetivos deste estudo foram: verificar a confiabilidade inter e intraexaminadores avaliadores na quantificação das medidas angulares obtidas a partir da fotogrametria computadorizada e a goniometria e determinar a confiabilidade paralela entre esses dois diferentes instrumentos de avaliação. MATERIAIS E MÉTODOS: 26 voluntários e 4 examinadores foram utilizados no estudo. A coleta foi realizada em 4 etapas sequenciais: demarcação dos pontos anatômicos de referência, mensuração e registro dos valores goniométricos, captação da imagem do voluntário com os marcadores fixados no corpo e avaliação do registro fotográfico no programa ImageJ. RESULTADOS: O goniômetro é um instrumento confiável na maioria das evidências, porém, a confiabilidade das medições depende principalmente da uniformização dos procedimentos. Considerações metodológicas relativas ao estabelecimento de confiabilidade e padronização da colocação dos marcadores se fazem necessárias, de modo a oferecer opções de avaliação ainda mais confiáveis para a prática clínica. CONCLUSÃO: Ambos os instrumentos são confiáveis e aceitáveis, porém, mais evidências ainda são necessárias para suportar a utilização desses instrumentos, pois poucos pesquisadores têm utilizado o mesmo desenho de estudo, e a comparação dos resultados entre eles muitas vezes são difíceis.