9 resultados para Temperatura del aire

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Climatic factors directly influence growth and productivity of plants inside greenhouses, where temperature can be considered one of the major parameter in this context. Thus, the aim of this research was to develop a low cost device for thermal sensing and data acquisition, and use it in data collection and analysis of spatial variability of temperature inside a greenhouse with tropical climate. The developed equipment for thermal measurements showed a high degree of accuracy and fast responses in measurements, proving its efficiency. The data analysis interpretations were made from the elaborations of variograms and of tridimensional maps generated by a geostatistical software. The processed data analysis presented that a greenhouse without thermal control has spatial variations of air temperature, both in the sampled horizontals layers as in the three analyzed vertical columns, presenting variations of up to 3.6 ºC in certain times.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The research aimed to evaluate the relationship between the thermal environment of the rest pens in a pig slaughterhouse and the surface temperature (ST) of the animals as well as the effect of intermittent water spraying on thermal comfort. There were two visits to slaughter industrial being in each selected three pens of rest, one for control treatment (no spray throughout the period) and two for the treatment of intermittent spraying water (30 minutes intervals with constant spray followed by 30 minutes then turned off). Assessments began at the time of discharging animals in which are taken the thermographic images from lots using an infrared thermographic camera. After housing in the pens, were registered the thermographic images and the respiratory frequency (RF) every five minutes for four hours. Were evaluated the temperature, relative humidity and temperature-humidity index (THI). Considering the values of THI was observed that the animals remained in a condition of comfort only at the time of his arrival at the slaughterhouse. The ST and RF of the animals kept in the pens without sprinkler system (control) showed a linear increase in function of time of day, with increasing temperature. The treatment with intermittent sprinkling of water was observed oscillatory behavior of the ST and RF, however it was always lower than the control treatment, even in times when the water sprinklers were turned off. The time required of spray to reduction and stabilization of the ST of the animals was limited to the combination of temperature and relative humidity, being estimated at 25 minutes at times of higher THI. The maximum environmental temperature during evaluation was 28.4 oC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: em pacientes sob intubação traqueal ou traqueostomia, a umidificação e o aquecimento do gás inalado são necessários para a prevenção de lesões no sistema respiratório, conseqüentes ao contato do gás frio e seco com as vias aéreas. O objetivo da pesquisa foi avaliar o efeito do sistema respiratório circular com absorvedor de dióxido de carbono do aparelho de anestesia Cícero da Dräger, quanto à capacidade de aquecimento e umidificação dos gases inalados, utilizando-se fluxo baixo (1 L.min-1) ou mínimo (0,5 L.min-1) de gases frescos. MÉTODO: O estudo aleatório foi realizado em 24 pacientes, estado físico ASA I, com idades entre 18 e 65 anos, submetidos à anestesia geral, utilizando-se a Estação de Trabalho Cícero da Dräger (Alemanha), para realização de cirurgias abdominais, os quais foram distribuídos aleatoriamente em dois grupos: grupo de Baixo Fluxo (BF), no qual foi administrado 0,5 L.min-1 de oxigênio e 0,5 L.min-1 de óxido nitroso e fluxo mínimo (FM), administrando-se somente oxigênio a 0,5 L.min-1. Os atributos estudados foram temperatura, umidade relativa e absoluta da sala de operação e do gás no sistema inspiratório. RESULTADOS: Os valores da temperatura, umidade relativa e umidade absoluta no sistema inspiratório na saída do aparelho de anestesia e junto ao tubo traqueal não apresentaram diferença significante entre os grupos, mas aumentaram ao longo do tempo nos dois grupos (BF e FM), havendo influência da temperatura da sala de operação sobre a temperatura do gás inalado, nos dois grupos estudados. Níveis de umidade e temperatura próximos dos ideais foram alcançados, nos dois grupos, a partir de 90 minutos. CONCLUSÕES: Não há diferença significante da umidade e temperatura do gás inalado utilizando-se baixo fluxo e fluxo mínimo de gases frescos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper investigates the role of the body in didactics. It looks up for points of contact between the functional sceneries of the classroom and some recent approaches, such like simplexity, neurosciences and enactivism. The two experiments presented they aim to demonstrate the importance of body awareness to improve the didactic quality. The first experience used a SenseWear Armband that provided data about the energetic expenditure of a teacher during diff erent activities in a lesson. Th e second experiment relied on a neurofeedback device integrated to a sensor, it detected body temperature with the aim of understanding the role of the body in the process of self-regulation-learning and management of attention and arousal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Radiography is usually the primary method of diagnosis to be used in the initial evaluation of the chest. In view of recent technological advances in ultrasound machines, noncardiac transthoracic ultrasound has become an important method of diagnosis for diseases of the lung, pleura, mediastinum and chest wall. Despite limitations due to the difficulty of efficient sound propagation in air, this exam allows fast decisions and makes sample collection safer and more effective. Knowledge of the sonographic chest anatomy is however restricted because of the artifact caused by the presence of air in lungs. When absent, it facilitates the detection of thoracic alterations. The aim of this review is to present the main abnormalities that are likely to be detected by ultrasonography.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Syndrome Obstructive Sleep Apnea (OSA) is defined by recurrent episodes of a total or partial obstruction of the airway during sleep, considered apnea and hypopnea respectively. Considered to be increasing by increasing the number of individuals with a disorder breathing, Being continually increasing the number of individuals with a respiratory disorder, OSA can be considered a public health problem that deserves greater attention in relation to diagnoses and treatments that are being conducted. The objective of this study is through a literature review which should be evaluated during the diagnosis and etiology, consequences and treatment of respiratory disorders not adequately treated. The etiology is multifactorial and may be associated with exogenous factors or pathological and anatomical factors. In addition to the own symptoms interfere with the quality of life of the individual, depending on the intensity, OSA can trigger more serious complications. This is a complex syndrome which may have varying degrees and irreversible consequences to the body. The choice of treatment should be based on clinical conditions, the severity of the apnea, the degree of urgency of treatment and the patient's preferences, but the treatments available will not be fully effective if there are no changes in lifestyle of it. The respiratory disorders can range from a simple nasal obstruction and intermittent obstruction more severe, emphasizing the importance of a complete diagnosis, which must be multidisciplinary, through a team relationship between doctor and dentist.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: O objetivo desta pesquisa foi estudar os efeitos agudos do contraste radiológico em situações de restrição de volume, avaliando-se os efeitos renais e cardiovasculares após a injeção intra-arterial de contraste radiológico de alta osmolaridade. MÉTODO: Participaram do estudo 16 cães anestesiados com tiopental sódico (15 mg.kg-1) e fentanil (15 µg.kg-1) em bolus, seguido de infusão contínua nas doses de 40 µg.kg-1.min-1 (tiopental sódico) e 0,1 µg.kg-1.min-1 (fentanil). Foi feita hidratação com solução de glicose a 5% (0,03 mL.kg-1.min-1) e a ventilação pulmonar foi controlada mecanicamente com ar comprimido. Foram verificados os seguintes atributos: freqüência cardíaca (FC); pressão arterial média (PAM); pressão da veia cava inferior (PVI); débito cardíaco (DC); hematócrito (Ht); fluxo plasmático efetivo renal (FPER); fluxo sangüíneo renal (FSR); ritmo de filtração glomerular (RFG); fração de filtração; resistência vascular renal (RVR); volume urinário (VU); osmolaridade plasmática e urinária; depuração osmolar, depuração de água livre e depuração de sódio e de potássio; sódio e potássio plasmáticos; excreção urinária e fracionária de sódio e potássio e temperatura retal. Estes atributos foram avaliados em quatro momentos: 30 (M1), 60 (M2), 90 (M3) e 120 (M4) minutos após o início da infusão de para-aminohipurato de sódio e creatinina (início da experiência). No momento 2, no grupo G1 foi feita injeção intra-arterial de solução fisiológica a 0,9% (1,24 mL.kg-1), e no grupo G2 foi injetado contraste radiológico (1,24 mL.kg-1) pela mesma via. RESULTADOS: O grupo G1 apresentou aumento da FC, do FPER, do FSR, da osmolaridade plasmática, da depuração de sódio e da excreção urinária de sódio; apresentou ainda diminuição da osmolaridade urinária, do potássio plasmático, da depuração de potássio e da temperatura retal. No grupo G2 ocorreu aumento da FC, da RVR, do VU, da depuração osmolar, da depuração de sódio e da excreção urinária e fracionária de sódio; ocorreu também redução do (a): hematócrito, ritmo de filtração glomerular, fração de filtração, osmolaridade urinária, depuração de água livre, sódio e potássio urinários, potássio plasmático e temperatura retal. CONCLUSÕES: Neste estudo, conclui-se que a injeção intra-arterial do contraste radiológico causou efeito bifásico na função renal. Inicialmente, provocou aumento da diurese e da excreção de sódio, mas, posteriormente, houve piora das condições hemodinâmicas e, conseqüentemente, da função renal, com aumento da resistência vascular renal e diminuição do ritmo de filtração glomerular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neste trabalho, foram determinados experimentalmente o calor específico, a condutividade térmica, difusividade térmica e densidade de suco de lulo na faixa de conteúdo de água entre 0,55 e 0,90 (p/p em base úmida) e em temperaturas entre 4 e 78,6 °C. A condutividade térmica e o calor específico foram obtidos utilizando-se o mesmo equipamento - uma célula constituída de dois cilindros concêntricos - operando em estado estacionário e não estacionário, respectivamente. A difusividade térmica foi obtida através do método de Dickerson e a densidade determinada por picnometria. Tanto a temperatura como o conteúdo de água apresentaram grande influência nos dados experimentais das propriedades termofísicas do suco de lulo. Os resultados obtidos foram utilizados na obtenção de modelos matemáticos para predizer estas propriedades em função da concentração e temperatura.