234 resultados para Techniques of Control of Behavior

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of massive lesions of the telencephalon on the behavioral repertoire of captive pigeons were investigated. The behavior of four birds with an intact telencephalon was compared to that of four birds submitted to ablation of telencephalic structures. Behavioral audio recording was done according to previously defined categories in three daily sessions for fifteen days. Experimental birds were followed up for one month. Immediately after the lesion, operated birds showed decreases in the occurrence of different behaviors such as coordinated movements, feeding, interaction, preening, maintenance, exploration and vocalization and increases in locomotion and discrete movements of the body when compared to the control birds (P < 0.05). Recovery of exploration (P < 0.05), feeding and localization was observed during the follow-up period. These data are interpreted as suggestive of a functional role of the telencephalon in the organization of behavior and a long-term recovery of behavior after detelencephalation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study was conducted to comparatively evaluate, in a prospective and randomized manner, 2 techniques for providing double-gloving protection during arch bar placement for intermaxillary fixation. Materials and Methods: A total of 42 consecutive patients in whom application of an Erich bar was indicated for intermaxillary fixation were equally divided into 2 groups. In group 1, 2 sterile surgical gloves were used; in group 2, a nonsterile disposable inner glove was used under a sterile surgical glove. Wilcoxon, Mann-Whitney, Kruskal-Wallis, and binomial statistical tests were used to analyze the findings. Results: A total of 103 perforations were found in the outer gloves (47 in group 1 and 56 in group 2), along with 5 perforations in inner gloves in both groups (α = .01). No significant statistical difference was found between groups in terms of inner glove perforations (α = .05). The nondominant hand presented with 70.9% of the perforations, statistically significant to 1%. Conclusions: Both double-gloving techniques were found to provide effective clinician protection. The use of a nonsterile disposable glove under the surgical glove is possible for less-invasive procedures, offering the same safety as using 2 sterile surgical gloves while decreasing operational costs. This method does not eliminate the need to change gloves when a perforation is suspected or noted during the surgery, however. © 2007 American Association of Oral and Maxillofacial Surgeons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adhesive restorations have increasingly been used in dentistry, and the adhesive system application technique may determine the success of the restorative procedure. The aim of this study was to evaluate the influence of the application technique of two adhesive systems (Clearfil SE Bond and Adper Scotchbond MultiPurpose) on the bond strength and adhesive layer of composite resin restorations. Eight human third molars were selected and prepared with Class I occlusal cavities. The teeth were restored with composite using various application techniques for both adhesives, according to the following groups (n = 10): group 1 (control), systems were applied and adhesive was immediately light activated for 20 seconds without removing excesses; group 2, excess adhesive was removed with a gentle jet of air for 5 seconds; group 3, excess was removed with a dry microbrush-type device; and group 4, a gentle jet of air was applied after the microbrush and then light activation was performed. After this, the teeth were submitted to microtensile testing. For the two systems tested, no statistical differences were observed between groups 1 and 2. Groups 3 and 4 presented higher bond strength values compared with the other studied groups, allowing the conclusion that excess adhesive removal with a dry micro-brush could improve bond strength in composite restorations. Predominance of adhesive fracture and thicker adhesive layer were observed via scanning electron microscopy (SEM) in groups 1 and 2. For groups 3 and 4, a mixed failure pattern and thinner adhesive layer were verified. Clinicians should be aware that excess adhesive may negatively affect bond strength, whereas a thin, uniform adhesive layer appears to be favorable. (Quintessence Int 2013;44:9-15)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Comparar duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropileno apoiando um reforço peritônio - aponeurótico ou suturada nas bordas do anel herniário 'em ponte . MÉTODOS: Foram operados 60 coelhos para a produção de hérnia incisional, em uma incisão mediana de 4 centímetros. Após 30 dias, metade dos animais foram operados com o fechamento primário da parede, com colocação de uma tela de polipropileno apoiando o reforço e a outra metade dos animais com a colocação da tela suturada nas bordas do anel herniárioem ponte . Os animais foram avaliados com 30 (M1), 60 (M2)e 90 (M3) dias de pós-operatório. Os parâmetros analisados foram a evolução clínica, análise da força de ruptura da cicatriz, estudo macroscópico, análise microscópica e morfométrica. RESULTADOS: Não foram observadas diferenças significantes com relação a força de ruptura e estudos histológicos nos dois grupos e vários momentos estudados. Não houve diferença estatística com relação às complicações, embora os animais que receberam a telaem ponte tiveram aderências mais firmes e intensas à parede abdominal. CONCLUSÕES: As duas técnicas utilizadas para correção da hérnia incisional em coelhos não mostraram diferenças significantes quanto a força de ruptura, análise histológica e morfométrica. O número de complicações foi semelhante, porém a aderência de órgãos da cavidade abdominal à área de cicatriz foi muito mais intensa no grupo em que a tela foi colocadaem ponte .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim was to analyze the prevalence of the stages of behavior change (BCS) and the perceived barriers to physical activity in older people residents in a medium size city of São Paulo state, Brazil. Seventy-nine older people participated of the study. The BCS was assessed by the Questionnaire of Behavior Chance Stages and those on perception of barriers by the Questionnaire on Barriers to the Practice of Physical Activity in Older People (QBPPAE). Statistical analyses was comprised by the Chi-square test (p<0.05). Data showed that: a) 64,6% of the older people do not practice physical activity and only 22,8% of them have been practicing it on a regular basis for more than 6 months; b) The most perceived barriers were: "Active enough", "Too old"; "Need to rest" and; "Disease or injury"; c) The BCS seems modulate significantly the perception of barriers (p<0.05). We can conclude that: a) most of the older people are in the pre-contemplation, contemplation and preparation stages of the BCS, yet; b) gender influences almost nothing with perception of barriers and; c) the BCS interferes with the type of perceived barriers. Such conclusions support the suggestions that it is necessary to develop specific strategies for different stages of behavior change if it is to minimize the barriers. This may help to find the most effective way to change to more active lifestyle in the elderly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A análise morfométrica da melanina tecidual pode subsidiar quantitativamente a pesquisa em discromias. Os autores demonstram três técnicas de análise de imagem digital que permitem a identificação dos pixels equivalentes à melanina na epiderme pela coloração de Fontana-Masson, possibilitando o cálculo da sua porcentagem nas diferentes camadas da epiderme, e discutem os principais elementos relacionados à análise e a necessidade de rigorosa padronização do processo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A low rate of physical activity (PA) participation is observed worldwide. The identification of feasible and reliable instruments able to accurately measuring PA and help in the development of interventions to promote PA are necessary. This study aimed to analyze the concordance between the Stages of Behavior Change Questionnaire (SBCQ) and the International Physical Activity Questionnaire (IPAQ long-version) in assessing adult leisure-time physical activity (LTPA). A total of 1.588 adults completed the IPAQ to assess LTPA and the participants who performed more than 10 min/week were classified in active individuals. Using the SBCQ, active individuals were those classified in the action or maintenance stage and inactive individuals were those classified in the precontemplation, contemplation or preparation stage. The concordance between SBCQ and IPAQ was found to be 0.80. Separated by gender, it was observed a concordance between the two instruments of 0.82 for women, and 0.77 for men. Regarding age group, it was found to be 0.81 for young and middle-aged adults, and 0.77 for older people. The SBCQ presented a very good concordance with IPAQ to assess LTPA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Linear Matrix Inequalities (LMIs) is a powerful too] that has been used in many areas ranging from control engineering to system identification and structural design. There are many factors that make LMI appealing. One is the fact that a lot of design specifications and constrains can be formulated as LMIs [1]. Once formulated in terms of LMIs a problem can be solved efficiently by convex optimization algorithms. The basic idea of the LMI method is to formulate a given problem as an optimization problem with linear objective function and linear matrix inequalities constrains. An intelligent structure involves distributed sensors and actuators and a control law to apply localized actions, in order to minimize or reduce the response at selected conditions. The objective of this work is to implement techniques of control based on LMIs applied to smart structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The continuous use of structural polymer composites in aeronautical industry has required the development of repairing techniques of damages found in different types of laminates. The most usually adopted procedure to investigate the repair of composite laminates has been by repairing damages simulated in laminated composite specimens. This work shows the influence of structural repair technique on mechanical properties of a typical carbon fiber/epoxy laminate used in aerospace industry. When analyzed by tensile test, the laminates with and without repair present tensile strength values of 670 and 892 MPa, respectively, and tensile modulus of 53.0 and 67.2 GPa, respectively. By this result, it is possible to observe a decrease of the measured mechanical properties of the repaired composites. When submitted to fatigue test, it is observed that in loads higher than 250 MPa, this laminate presents a low life cycle (lower than 400,000 cycles). The fatigue performance of both laminates is comparable, but the non-repaired laminate presented higher tensile and fatigue resistance when compared with the repaired laminate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical behavior of a coating of cobalt oxide on cold-rolled steel in alkaline sodium sulfate was Studied using the electrochemical techniques of open-circuit potential measurements and electrochemical impedance spectroscopy. The coating was prepared at different annealing temperatures ranging from 350 to 750 degreesC and characterized by SEM, EDX and XRD. Below 550 degreesC the composition of the coating was basically of Co3O4. At 750 degreesC CoO was formed and big cracks appeared on the film exposing an inner layer of iron oxides. Analysis of the EIS data is very difficult because of the complexity of the interface structure. It can be inferred that the charge transfer resistance of the coatings prepared at 350 and 450 C were higher than those for the coatings prepared at temperatures above 550 degreesC. (C) 2002 Published by Elsevier B.V. Ltd.