9 resultados para TRACE CONCENTRATIONS

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

30.00% 30.00%

Publicador:

Resumo:

One hundred and twenty six piglets from a commercial genetic strain weaned at 21 days of age (6.11±0.42 kg) were used to evaluate the effects of supplementation levels of organic sources of trace minerals in the diets of weaned piglets on performance, occurrence of diarrhea, excretion of copper and zinc in the feces, and hematological parameters. A completely randomized block design was adopted, composed of six treatments (diets containing 100% of inorganic trace minerals premix at 3.00 kg/T; diets containing 0, 25, 50, 75 or 100% of organic trace minerals premix, equivalent to 0; 0.75; 1.50; 2.25 or 3.00 kg/T, respectively), seven replicates and three animals per plot. During the experimental period (from 21 to 63 days of age), the increasing levels of organic trace minerals premix in the diets determined a quadratic effect on daily weight gain (DWG), feed conversion (FC), percentage of hematocrit (Ht), hemoglobin (Hb), mean corpuscular hemoglobin (MCH), mean corpuscular volume (MCV), platelets (Pt), and a linear increase of Cu and Zn concentrations in feces. The comparison of means between the treatment with inorganic trace minerals premix and the other treatments showed that piglets fed diets without trace minerals premix had lower values of DWG, Ht, Hb, MCH, MCV, Pt and the worst FC value of piglets fed diets containing 25% of organic trace minerals premix presented lower values of Ht and Hb, in comparison with those fed diets with 100% of inorganic trace minerals premix. Inorganic trace minerals premix can be substituted by organic trace minerals premix at a lower level of inclusion in diets for weaned piglets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Langmuir films of a tetracarboxylic perylene derivative and polypyrrole display condensed surface pressure isotherms that are shifted when Cu2+ ions are added to the ultrapure water subphase. These films were transferred onto interdigitated gold electrodes leading to Y-type Langmuir-Blodgett (LB) films. The electrodes modified with 5-layer LB films were immersed into a flask with ultrapure water and water containing Cu2+ ions at concentrations ranging from mM to muM. Impedance measurements indicated a distinct electrical response for the two types of films. Although the materials chosen have no specificity for ionic metals, they can be combined for detecting trace levels of Cu2+, which may be exploited in water quality monitoring. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An on-line dialysis flow system coupled to inductively coupled plasma mass spectrometry to determine trace elements in serum samples by isotope dilution is presented. Isotope dilution was performed on samples incubated with enriched Cu-65, Zn-66, Se-77 and Pb-206 for 24 h at 36degreesC prior to dialysis to quantified total element concentrations. The sample and acceptor solutions flowed through the dialysis unit with cellophane membrane placed in between the compartments. The serum sample (1 mL) was left to recycle in a closed path while the acceptor solution was continuously pumped along the dialyzer channel and through a cationic AG50W X-8 resin column. After 10 min, around 70% of Na, K and Cl migrate from the sample. Three replicate injections of 0.1 mL were performed for the clean sample after each separation step. The on-line coupling of the dialyzer to ICP-MS allowed isotope dilution for total element determination either in the cleaned sample or by eluting the cations retained in the resin to be carried out. Results demonstrated no matrix effects from alkaline elements or spectral interference from ArNa+ on Cu-63, ArCl+ on Se-77 and (SO2+)-S-34 on Zn-66. The precision of isotope ratio measurements for Cu and Zn was around 1% and for Se and Pb was around 2.5%. The values found for the reference serum sample IMEP-17 were in good agreement with the certified values for Cu, Zn and Se.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sewage sludge may be used as an agricultural fertilizer, but the practice has been criticized because sludge may contain trace elements and pathogens. The aim of this study was to compare the effectiveness of total and pseudototal extractants of Cu, Fe, Mn, and Zn, and to compare the results with the bioavailable concentrations of these elements to maize and sugarcane in a soil that was amended with sewage sludge for 13 consecutive years and in a separate soil that was amended a single time with sewage sludge and composted sewage sludge. The 13-year amendment experiment involved 3 rates of sludge (5, 10, and 20 t ha-1). The one-time amendment experiment involved treatments reflecting 50, 100, and 200 % of values stipulated by current legislation. The metal concentrations extracted by aqua regia (AR) were more similar to those obtained by Environmental Protection Agency (EPA) 3052 than to those obtained by EPA3051, and the strongest correlation was observed between pseudo(total) concentrations extracted by AR and EPA3052 and bioavailable concentrations obtained by Mehlich III. An effect of sewage sludge amendment on the concentrations of heavy metals was only observed in samples from the 13-year experiment. © 2012 Springer Science+Business Media B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The application and better understanding of traditional and new breast tumor biomarkers and prognostic factors are increasing due to the fact that they are able to identify individuals at high risk of breast cancer, who may benefit from preventive interventions. Also, biomarkers can make possible for physicians to design an individualized treatment for each patient. Previous studies showed that trace elements (TEs) determined by X-Ray Fluorescence (XRF) techniques are found in significantly higher concentrations in neoplastic breast tissues (malignant and benign) when compared with normal tissues. The aim of this work was to evaluate the potential of TEs, determined by the use of the Energy Dispersive X-Ray Fluorescence (EDXRF) technique, as biomarkers and prognostic factors in breast cancer. Methods By using EDXRF, we determined Ca, Fe, Cu, and Zn trace elements concentrations in 106 samples of normal and breast cancer tissues. Cut-off values for each TE were determined through Receiver Operating Characteristic (ROC) analysis from the TEs distributions. These values were used to set the positive or negative expression. This expression was subsequently correlated with clinical prognostic factors through Fisher’s exact test and chi-square test. Kaplan Meier survival curves were also evaluated to assess the effect of the expression of TEs in the overall patient survival. Results Concentrations of TEs are higher in neoplastic tissues (malignant and benign) when compared with normal tissues. Results from ROC analysis showed that TEs can be considered a tumor biomarker because, after establishing a cut-off value, it was possible to classify different tissues as normal or neoplastic, as well as different types of cancer. The expression of TEs was found statistically correlated with age and menstrual status. The survival curves estimated by the Kaplan-Meier method showed that patients with positive expression for Cu presented a poor overall survival (p < 0.001). Conclusions This study suggests that TEs expression has a great potential of application as a tumor biomarker, once it was revealed to be an effective tool to distinguish different types of breast tissues and to identify the difference between malignant and benign tumors. The expressions of all TEs were found statistically correlated with well-known prognostic factors for breast cancer. The element copper also showed statistical correlation with overall survival.